Adds new wall sprites, cleans up existing ones, adds to test map #192
Annotations
10 errors, 1 warning, and 1 notice
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Atmospherics APC) at Atmospherics (115,136,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Central Primary Hallway APC) at Central Primary Hallway (115,134,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Construction Area APC) at Construction Area (118,123,2) with dir (2 | SOUTH) has pixel_y value 0 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Bridge APC) at Bridge (121,134,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Primary Tool Storage APC) at Primary Tool Storage (128,126,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Engineering APC) at Engineering (129,137,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Gravity Generator Room APC) at Gravity Generator Room (133,137,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Arrival Shuttle Hallway APC) at Arrival Shuttle Hallway (137,133,2) with dir (4 | EAST) has pixel_x value -11 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Service Hallway APC) at Service Hallway (118,123,3) with dir (2 | SOUTH) has pixel_y value 0 - should be -25. Use the directional/ helpers!
|
Run Tests:
code/modules/unit_tests/mapping.dm#L19
APC: (the Engineering Storage APC) at Engineering Storage (118,123,4) with dir (2 | SOUTH) has pixel_y value 0 - should be -25. Use the directional/ helpers!
|
Node.js 16 actions are deprecated. Please update the following actions to use Node.js 20: actions/checkout@v3, actions/cache@v3, actions/upload-artifact@v3. For more information see: https://github.blog/changelog/2023-09-22-github-actions-transitioning-from-node-16-to-node-20/.
|
Run Tests:
code/modules/unit_tests/subsystem_init.dm#L12
Lua Scripting (/datum/controller/subsystem/lua) is a subsystem meant to initialize but doesn't get set as initialized.
This subsystem is marked as SS_OK_TO_FAIL_INIT. This is still a bug, but it is non-blocking.
|
The logs for this run have expired and are no longer available.
Loading