Merge pull request #60 from Jalle19/readme-updates
Browse files Browse the repository at this point in the history
Add known issues section and table of contents
  • Loading branch information
Jalle19 authored Nov 16, 2022
2 parents e739fa5 + 23e69ad commit eb92876
Showing 1 changed file with 42 additions and 0 deletions.
42 changes: 42 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -13,6 +13,26 @@ unit's computer board.
The REST endpoints for enabling/disabling the various modes are designed to be consumed by
https://www.home-assistant.io/integrations/switch.rest/ with minimal effort. See examples in the `docs/` directory.

## Table of contents

* [Features](#features)
* [Requirements](#requirements)
* [Installation](#installation)
* [Running as a systemd service](#running-as-a-systemd-service)
* [Running as a Home Assistant OS addon](#running-as-a-home-assistant-os-addon)
* [Usage](#usage)
* [HTTP endpoints](#http-endpoints)
* [GET /summary](#get-summary)
* [GET /mode/{flag}](#get-modeflag)
* [GET /alarms](#get-alarms)
* [POST /mode/{flag}](#post-modeflag)
* [POST /setting/{setting}/{value}](#post-settingsettingvalue)
* [MQTT support](#mqtt-support)
* [Home Assistant MQTT discovery](#home-assistant-mqtt-discovery)
* [Known issues](#known-issues)
* [License](#license)
* [Credits](#credits)

## Features

* HTTP API for reading temperatures, modes and settings, as well as changing some settings
Expand Down Expand Up @@ -342,6 +362,28 @@ in Home Assistant automatically through the MQTT integration. The following enti
![](https://raw.githubusercontent.com/Jalle19/eda-modbus-bridge/master/docs/readme_ha3.png "Home Assistant sensors")
![](https://raw.githubusercontent.com/Jalle19/eda-modbus-bridge/master/docs/readme_ha4.png "Home Assistant configuration")

## Known issues

* Some ventilation units sometimes trip the "TE20 Huoneilma kuuma" alarm when Modbus is used and a room temperature
sensor has not been connected to the main board. This can be alleviated by reducing the polling interval from 10
seconds to something like 30 seconds, or fixed permanently by either connecting an NTC10 temperature sensor or a 10
kiloohm resistor to the sensor input terminals (not tested, but confirmed by Enervent).

* It is not possible to adjust the ventilation level when the unit is operating in normal mode. Enervent has confirmed
that this is a limitation in the protocol and there is no direct solution. A workaround is to repurpose one of the
modes, e.g. "long away", to be a "manual control" mode, since the ventilation level can be adjusted for all non-
normal modes of operation. A slight caveat with this is that the temperature target is also reduced, and the
temperature target reduction setting doesn't always seem to accept values below 2 degrees Celsius. Experiment with
these values to find something that suits your use case, or trust the built-in automation in the ventilation unit to
do its job.

## License

GNU GENERAL PUBLIC LICENSE 3.0

Some documentation under `docs/` is proprietary.

## Credits

Credits to Jaakko Ala-Paavola for creating https://web.archive.org/web/20201020102005/http://ala-paavola.fi/jaakko/doku.php?id=pingvin
and self-hosting a copy of the relatively hard to find EDA modbus register PDF document.