@@ -0,0 +1,101 @@ | ||
{ | ||
"manufacturer": "Safe Grow", | ||
"manufacturerId": "0x013c", | ||
"label": "NSG-AB-02", | ||
"description": "Smart Outlet Plug", | ||
"devices": [ | ||
{ | ||
"productType": "0x0001", | ||
"productId": "0x002f" | ||
} | ||
], | ||
"firmwareVersion": { | ||
"min": "0.0", | ||
"max": "255.255" | ||
}, | ||
"paramInformation": [ | ||
{ | ||
"#": "5", | ||
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on" | ||
}, | ||
{ | ||
"#": "6", | ||
"$import": "~/templates/master_template.json#base_enable_disable", | ||
"label": "Allow Turning Off", | ||
"description": "When disabled, the device will not turn off in response to Z-Wave commands or physical interaction.", | ||
"defaultValue": 1, | ||
"options": [ | ||
{ | ||
"label": "Disable", | ||
"value": 0 | ||
}, | ||
{ | ||
"label": "Enable", | ||
"value": 1 | ||
} | ||
] | ||
}, | ||
{ | ||
"#": "7", | ||
"label": "LED Indicator Mode", | ||
"valueSize": 1, | ||
"defaultValue": 1, | ||
"allowManualEntry": false, | ||
"options": [ | ||
{ | ||
"label": "LED on when switch is on", | ||
"value": 1 | ||
}, | ||
{ | ||
"label": "LED on when switch is off", | ||
"value": 2 | ||
} | ||
] | ||
}, | ||
{ | ||
"#": "8", | ||
"label": "Auto Off Timer", | ||
"valueSize": 2, | ||
"unit": "seconds", | ||
"minValue": 0, | ||
"maxValue": 32767, | ||
"defaultValue": 0, | ||
"options": [ | ||
{ | ||
"label": "Disable", | ||
"value": 0 | ||
} | ||
] | ||
}, | ||
{ | ||
"#": "9", | ||
"label": "Response to Z-Wave Off Command", | ||
"valueSize": 1, | ||
"defaultValue": 0, | ||
"allowManualEntry": false, | ||
"options": [ | ||
{ | ||
"label": "Turn off", | ||
"value": 0 | ||
}, | ||
{ | ||
"label": "Ignore", | ||
"value": 1 | ||
}, | ||
{ | ||
"label": "Toggle", | ||
"value": 2 | ||
}, | ||
{ | ||
"label": "Turn on", | ||
"value": 3 | ||
} | ||
] | ||
} | ||
], | ||
"metadata": { | ||
"inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. \n2. Pressing On/Off button three times within 2 seconds will enter inclusion mode.", | ||
"exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. \n 2. Pressing On/Off button three times within 2 seconds will enter exclusion mode. \n3. Node ID has been excluded", | ||
"reset": "Use this procedure only in the event that the primary controller is lost or otherwise inoperable. \n1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. \n2. Within 1 second, press On/Off button again for 5 seconds. \n3. IDs are excluded" | ||
} | ||
} |