[3.12] gh-123832: Adjust socket.getaddrinfo
docs for better POSIX compliance (GH-126182)
#126824
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
getaddrinfo
fails on Illumos, inconsistent elsewhere if port is, but type & protocol are not specified #123832: Adjustsocket.getaddrinfo
docs for better POSIX complianceThis changes nothing changes for CPython supported platforms,
but hints how to deal with platforms that stick to the letter of
the spec.
It also marks
socket.getaddrinfo
as a wrapper aroundgetaddrinfo(3)
;specifically, workarounds to make the function work consistently across
platforms are out of scope in its code.
Include wording similar to the POSIX's “by providing options and by
limiting the returned information”, which IMO suggests that the
hints limit the resulting list compared to the defaults, but can
be interpreted differently. Details are added in a note.
Specifically say that this wraps the underlying C function. So, the
details are in OS docs. The “full range of results” bit goes away.
Use
AF_UNSPEC
rather than zero for the family default, althoughI don't think a system where it's nonzero would be very usable.
Suggest setting proto and/or type (with examples, as the appropriate
values aren't obvious). Say why you probably want to do that that
on all systems; mention the behavior on the “letter of the spec”
systems.
Suggest that the results should be tried in order, which is,
AFAIK best practice -- see RFC 6724 section 2, and its predecessor
from 2003 (which are specific to IP, but indicate how people use this):
(cherry picked from commit ff0ef0a)
Co-authored-by: Petr Viktorin [email protected]
Co-authored-by: Carol Willing [email protected]
📚 Documentation preview 📚: https://cpython-previews--126824.org.readthedocs.build/