release 2.1.21
Changes:
- Quantification of compounds in LC-MS datasets is now possible.
- "Annotated Features Overview" added (a table of all features matched in all LC-MS files).
- "Simulate Isotopic Pattern" feature added.
- "Calculate Molecular Formula" feature added.
- The names corresponding to molecular formulas of compounds identified in "Compound Search - MS, LC-MS, MSI" mode can now be searched in PubChem.
- The range of retention time can now be limited in the settings dialog if LC-MS data is processed.
- Retention time of individual database compounds can also be limited if LC-MS data is processed.
- "Minimum Intensity of Highest Peak in Isotopic Pattern" parameter was added into the Settings dialog.
- "54Fe/56Fe Ratio" parameter was added into the Settings dialog.
- Line/Profile mass spectra can now optionally be converted by CompassXtract from baf files.
- Waters data support improved.
- EIC chromatogram is now visible by default.
- Calculation of FDRs (LC-MS and MSI data) can optionally be disabled.
- Copy to clipboard function (CTRL+C) improved in Building Block, Sequence/Compound, and Modification editors.
- Remove duplicate rows feature added in Sequences/Compounds Editor.
- Export matched formulas to a compound database - feature available in "Summary Table of Matched Peaks" and "Annotated Features Overview" if "Compound Search - MS, LC-MS, MSI" mode was used.
- Results files (*.res) are now backwards compatible (starting from version 2.0.8).
- Data processing tab added in Preferences dialog.
- Compounds in NP Atlas and COCONUT can now be referenced from Sequence/Compound Editor.
- Bookmarks toolbar was added and corresponding tab was fixed in Preferences dialog.
- Unused parameters are now automatically hidden in the Settings dialog.
- Multiple LC-MS files can now be processed in a batch.
- Multiple threads can now be used if LC-MS or MSI data are processed.
- Image fusion improved:
- Current configuration of layers can now be loaded/saved.
- Open image function was improved.
- Import dialog was added to open a batch of microscopy images FEI (SEM) / Leica (optical and fluorescence).
- Optical and fluorescence microscopy images can now be opened directly from *.lif files (Leica).
- Horizontal and vertical flip feature added for microscopy images.
- Name and magnification is now visible for every microscopy layer.
- Navigation buttons were added to browse microscopy layers (Previous, Next).
- Maximum number of microscopy layers was increased to 200.
- A dropdown menu was added to change the navigation layer of any microscopy layer.
- Keep aspect ratio feature added when resizing a region (CTRL + resize by mouse).
- Clear all/individual layers features added.
- Some other minor bugs and performance issues were fixed and minor improvements were made.