Skip to content

This MCC based MPLAB X example shows how to calibrate the gain and offset of the OPAMP when configured as a Programmable Gain Amplifier (PGA). The internal DAC and ADC are used to perform the calibration procedure. No external components are required.

License

Notifications You must be signed in to change notification settings

microchip-pic-avr-examples/avr128db48-opamp-gain-and-offset-calibration-mplab-mcc

Repository files navigation

MCHP

Gain and Offset Calibration of the Analog Signal Conditioning (OPAMP) Peripheral

A new feature introduced in the AVR® DB MCU is the Analog Signal Conditioning (OPAMP) peripheral. In this example, the OPAMP is configured as a Programmable Gain Amplifier (PGA). The internal Digital to Analog Converter (DAC) and the internal Analog to Digital Converter (ADC) are used to calibrate the gain and offset for the PGA. For more information on the calibration procedure, see the application note.

Related Documentation

Software Used

Microchip’s free MPLAB X IDE, compiler and MPLAB Code Configurator (MCC) graphical code generator are used throughout the application firmware development to provide easy and hassle-free user experience. Following are the tool versions used for this example:

Hardware Used

Setup

  • Connect the AVR128DB48 Curiosity Nano board to your computer using a USB cable
  • Download and install all software components as listed under 'Software Used' (note that MPLAB Xpress IDE is an online tool that cannot be downloaded)
  • No external hardware setup needed

Peripherals Configuration using MCC

Added Peripherals

Add the required peripherals: ADC0, DAC0 and OPAMP. These are found under Drivers in the Device Resources window. Note that the peripheral VREF is added automatically when ADC0 or DAC0 is added, since these peripherals require the VREF peripheral.

melody_cfg_1

These System peripherals are added automatically: CLKCTRL, Configuration Bits, Interrupt Manager and Pins.

melody_cfg_2

System Configuration

The added peripherals will show up in the Builder window of MCC like shown below. Click on each peripheral block to get to each peripherals driver configuration Easy View.

builder

System Configuration: CLKCTRL

The default clock configuration is used, no changes are needed. The CLKCTRL Easy View should look like the picture below.

CLKCTRL1

CLKCTRL2

System Configuration: Configuration Bits

The default configuration for Configuration Bits are used, and should look like this.

config_bits

System Configuration: Interrupt Manager

Use the default setup for Interrupt Manager, no interrupts are used in this example.

interrupt_setup

System Configuration: PINS

The PINS configuration is made up of two boxes: the Pins Grid View and the Pins configuration box. In the Pins Grid View, no changes are needed. The pins will be automatically highlighted green and show as "locked" during configuration. Note that the screen shot shows final PINS configuration, after all peripherals are configured. This will initially look different, before the OPAMP module is configured.

pins_grid

In the Pins configuration box, now the pins that are added will show in column Pin Name (PD2, PD6). In column Custom Name the example is using "OPAMP0_OUT" for PD2 and "DAC0_OUT" for PD6. Note also here that initially more pins will show up, and the screenshot shown is after all peripherals are configured.

pins

VREF Configuration

Both the DAC0 and ADC0 peripherals are using the VREF peripheral.

  • Enable the internal voltage reference for ADC0 by turning on the "Enable Force ADC Voltage Reference" button
  • Set the reference voltage source to "Internal 2.500V reference"
  • Enable the internal voltage reference for DAC0 by turning on the "Enable Force DAC Voltage Reference" button
  • Set the reference voltage source to "Internal 2.500V reference"

VREF_setup

ADC0 Configuration

  • ADC0 must be enabled by turning on the "Enable ADC" button
  • Set Clock Pre-Scaler to "CLK_PER divided by 4", and Sample Length to "32"
  • Turn off "Left Adjust Result" button

ADC0_setup

DAC0 Configuration

  • DAC0 must be enabled by turning on the "Enable DAC" button
  • The DAC0 output must be enabled by turning on the "Enable Output on DAC" button

DAC0_setup

OPAMP Configuration

  • The OPAMP system must be enabled by turning on the "Enable OPAMP System" button
  • Set the input range to "FULL"
  • Select mode "SINGLE OPAMPs"
  • Enable OP0 by turning on button "Enable OP0", and configure as "Non-Inverting Programmable Gain Amplifier"
  • Disable OP1 and OP2 by turning off buttons "Enable OP1" and "Enable OP2"

OPAMP_setup1

  • Configure the Positive Input MUX to "DAC output" ("DAC" in data sheet)
  • Set the Resistor Ladder Pair Wiper MUX to "R1 = 1R, R2 = 15R, R2/R1 = 15" ("WIP7" in data sheet)
  • Enable the "Run in Standby Mode" button
  • Set the Output Mode to "Output Driver in Normal Mode"
  • Set Software Enable to "Always On"
  • Set the Settle Time to 0 µs

OPAMP_setup2

Operation

  • Download the zip archive or clone the example to get the source code

  • Open avr128db48-opamp-gain-and-offset-calibration-mplab-mcc.X in MPLAB® X or MPLAB® Xpress IDE

  • Set the project as Main project by right clicking the project name in the Projects window (Ctrl+1) and select "Set as Main Project" from the drop-down menu

  • Program the project to the AVR128DB48 Curiosity Nano:

    • First clean and build the project by pressing the Clean and Build Main Project button

    clean_and_build

    • Then make and program the project to the AVR128DB48 by clicking the Make and Program Device Main Project button

    make_and_prog

  • If no tool has been selected, a window will open. Select the AVR128DB48 Curiosity Nano tool. The tool can also be selected in the project settings.

  • For details on the code, see inline comments in the .c files and the Appnote referenced in the Related Documentation section (AN3633)

  • To verify that the code is working as intended, insert a breakpoint on the last hyphen of the function void PGA_Calibrate(void) and press the Debug Main Project button

debug1

  • When the brakpoint is triggered, you can hover the mouse pointer over the variables calib_data.gain (shown in screenshot) and calib_data.offset_mv. The value for gain should be somewhere around 16, and the value for offset should be in the region of some millivolts (positive as well as negative number). The numbers should be similar with small variations between consecutive measurements (debug runs).

Summary

After going through this example, you should be able to calibrate the gain and offset of the OPAMP configured as a PGA. The calibrated gain and input offset values should be used by the application code for any calculations that involve gain and/or offset.

About

This MCC based MPLAB X example shows how to calibrate the gain and offset of the OPAMP when configured as a Programmable Gain Amplifier (PGA). The internal DAC and ADC are used to perform the calibration procedure. No external components are required.

Topics

Resources

License

Stars

Watchers

Forks

Packages