Expand Up @@ -266,34 +266,65 @@ def reg_to_value(self, regs: RegType) -> ValType:
"""Decode HV Inverter faults."""
faults = {
1: "DC Inversed Failure",
2: "DC insula�on impedance permanent fault",
3: "DC leakage current fault",
4: "Ground fault GFDI",
5: "Read the memory error",
6: "Write the memory error",
7: "DC START Failure",
8: "GFDI grounding touch failure",
9: "IGBT damaged by excessive drop voltage",
10: "Auxiliary power supply failure",
11: "AC main contactor errors",
12: "AC auxiliary contactor errors",
13: "Working mode change",
14: "DC over current SW Failure",
15: "AC over current SW Failure",
10: "Aux Power Board Failure",
16: "DC Ground Leakage current fault",
18: "AC over current TZ",
19: "All hardware failure synthesis",
20: "DC over current",
21: "DC HV Bus over current",
22: "Remote Emergency stop",
23: "AC leakage current is transient over current",
24: "DC insulation impedance",
25: "DC feedback fault",
26: "DC busbar imbalanced",
29: "Parallel comms cable",
27: "DC end insula�on error",
28: "Inverter 1 DC high fault",
29: "Parallel comms cable/AC load switch failure",
30: "AC main contactor failure",
31: "Relay open circuit fault",
32: "Inverter 2 dc high fault",
33: "AC Overcurrent",
34: "AC Overload (backup)",
35: "No AC grid",
36: "AC grid phase error",
37: "AC three-phase voltage unbalance failure",
38: "AC three-phase current unbalance failure",
39: "AC over current (one cycle)",
40: "DC over current",
41: "Parallel system stopped",
42: "AC line low voltage",
43: "AC Line V,W over voltage",
44: "AC Line V,W low voltage",
45: "AC Line U,V over voltage",
46: "Battery 1 fault",
49: "Battery 2 fault",
47: "AC grid freq too high",
48: "AC grid freq too low",
49: "Battery 2 fault",
50: "V phase grid current DC component over current",
51: "W phase grid current DC component over current",
52: "DC voltage too high",
53: "DC voltage too low",
54: "battery 1 voltage high",
55: "battery 2 voltage high",
56: "battery 1 voltage low",
57: "battery 2 voltage low",
58: "bms communication lost",
59: "AC grid V over current",
60: "AC grid W over current",
61: "Reactor A phase over current",
62: "DRM stop activated",
63: "ARC fault",
64: "Heat sink tempfailure",
Expand Down