@@ -0,0 +1,33 @@ | ||
# | ||
# Battery data to be sent continuously | ||
# | ||
|
||
float16 temperature_cells # [C] : Pack mounted thermistor (preferably installed between cells), NAN: field not provided | ||
float16 temperature_pcb # [C] : Battery PCB temperature (likely output FET(s) or current sense resistor), NAN: field not provided | ||
float16 temperature_other # [C] : Application dependent, NAN: field not provided | ||
float32 current # [A] : Positive: defined as a discharge current. Negative: defined as a charging current, NAN: field not provided | ||
float32 voltage # [V] : Battery voltage | ||
float16 state_of_charge # [%] : The estimated state of charge, in percent remaining (0 - 100). | ||
uint8 slot_id # : The physical location of the battery on the aircraft. 0: field not provided | ||
float32 capacity_consumed # [Ah] : This is either the consumption since power-on or since the battery was full, depending on the value of STATUS_FLAG_CAPACITY_RELATIVE_TO_FULL, NAN: field not provided | ||
uint32 status_flags # : Fault, health, readiness, and other status indications | ||
|
||
uint32 STATUS_FLAG_READY_TO_USE = 1 | ||
uint32 STATUS_FLAG_CHARGING = 2 | ||
uint32 STATUS_FLAG_CELL_BALANCING = 4 | ||
uint32 STATUS_FLAG_FAULT_CELL_IMBALANCE = 8 | ||
uint32 STATUS_FLAG_AUTO_DISCHARGING = 16 | ||
uint32 STATUS_FLAG_REQUIRES_SERVICE = 32 | ||
uint32 STATUS_FLAG_BAD_BATTERY = 64 | ||
uint32 STATUS_FLAG_PROTECTIONS_ENABLED = 128 | ||
uint32 STATUS_FLAG_FAULT_PROTECTION_SYSTEM = 256 | ||
uint32 STATUS_FLAG_FAULT_OVER_VOLT = 512 | ||
uint32 STATUS_FLAG_FAULT_UNDER_VOLT = 1024 | ||
uint32 STATUS_FLAG_FAULT_OVER_TEMP = 2048 | ||
uint32 STATUS_FLAG_FAULT_UNDER_TEMP = 4096 | ||
uint32 STATUS_FLAG_FAULT_OVER_CURRENT = 8192 | ||
uint32 STATUS_FLAG_FAULT_SHORT_CIRCUIT = 16384 | ||
uint32 STATUS_FLAG_FAULT_INCOMPATIBLE_VOLTAGE = 32768 | ||
uint32 STATUS_FLAG_FAULT_INCOMPATIBLE_FIRMWARE = 65536 | ||
uint32 STATUS_FLAG_FAULT_INCOMPATIBLE_CELLS_CONFIGURATION = 131072 | ||
uint32 STATUS_FLAG_CAPACITY_RELATIVE_TO_FULL = 262144 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,19 @@ | ||
# | ||
# Battery data to be sent statically upon request or periodically at a low rate | ||
# Recommend that this message is sent at a maximum of 1Hz and nominally 0.2 Hz (IE: once every 5 seconds.) | ||
|
||
uint8[<=50] name # : Formatted as manufacturer_product, 0 terminated | ||
uint8[<=32] serial_number # : Serial number in ASCII characters, 0 terminated | ||
uint8[<=9] manufacture_date # : Manufacture date (DDMMYYYY) in ASCII characters, 0 terminated | ||
float32 design_capacity # [Ah] : Fully charged design capacity. 0: field not provided. | ||
uint8 cells_in_series # : Number of battery cells in series. 0: field not provided. | ||
float16 nominal_voltage # [V] : Battery nominal voltage. Used for conversion between Wh and Ah. 0: field not provided. | ||
float16 discharge_minimum_voltage # [V] : Minimum per-cell voltage when discharging. 0: field not provided. | ||
float16 charging_minimum_voltage # [V] : Minimum per-cell voltage when charging. 0: field not provided. | ||
float16 charging_maximum_voltage # [V] : Maximum per-cell voltage when charged. 0: field not provided. | ||
float32 charging_maximum_current # [A] : Maximum pack continuous charge current. 0: field not provided. | ||
float32 discharge_maximum_current # [A] : Maximum pack continuous discharge current. 0: field not provided. | ||
float32 discharge_maximum_burst_current # [A] : Maximum pack discharge burst current for 30 seconds. 0: field not provided | ||
float32 full_charge_capacity # [Ah] : Predicted battery capacity when fully charged (accounting for battery degradation), NAN: field not provided | ||
uint16 cycle_count # : Lifetime count of the number of charge/discharge cycles (https://en.wikipedia.org/wiki/Charge_cycle). UINT16_MAX: field not provided. | ||
uint8 state_of_health # [%] : State of Health (SOH) estimate, in percent (0 - 100). UINT8_MAX: field not provided. |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,8 @@ | ||
# | ||
# Battery cell voltages | ||
# Rate: set by parameter on smart battery (default off) | ||
# | ||
|
||
float16[<=24] voltages # [Volt] | ||
uint16 index # Index of the first cell in the array, index 0 is cells at array indices 0 - 23, index 24 is cells at array indices 24 - 47, etc. | ||
|