Notifications
You must be signed in to change notification settings - Fork 178
Battery: Ampera‐e 64 kWh
Caution
Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.
To use the Bolt/Ampera battery, enable the line #define BOLT_AMPERA_BATTERY
setting in USER_SETTINGS
The following diagrams will help you to connect to the CAN buses on the Opel/Chevy batteries:
Note
These batteries have multiple CAN buses that needs to be jumpered together to form one large CAN bus
Example, development environment with contactor control via GPIO, and all 3x CAN buses connected together as one single bus
Stekker X 357 OEM 33472-1259 Service Connector 19333239
- X357
X358
Cotactors must be connected with lilygo via the GPIO pins see: https://github.com/dalathegreat/Battery-Emulator/wiki/Contactor-Control-via-GPIO-pins