Skip to content

Blazor UI Demo CD

Blazor UI Demo CD #197

Manually triggered June 13, 2024 15:57
Status Failure
Total duration 12m 43s
Artifacts 3

blazorui.demo.cd.yml

on: workflow_dispatch
build api + blazor web
2m 58s
build api + blazor web
build blazor hybrid (windows)
3m 24s
build blazor hybrid (windows)
build blazor hybrid (android)
12m 34s
build blazor hybrid (android)
build blazor hybrid (iOS-macOS)
6m 14s
build blazor hybrid (iOS-macOS)
deploy api + blazor
0s
deploy api + blazor
Fit to window
Zoom out
Zoom in

Annotations

4 errors and 80 warnings
deploy api + blazor
Unable to resolve action `jakejarvis/[email protected]`, unable to find version `0.3.0`
build blazor hybrid (android)
obj/Release/net9.0-android/AndroidManifest.xml does not exist
build blazor hybrid (android)
obj/Release/net9.0-android/AndroidManifest.xml does not exist
build blazor hybrid (android)
Process completed with exit code 1.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L5
Non-nullable property 'Name' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L6
Non-nullable property 'Parameters' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L7
Non-nullable property 'Output' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L8
Non-nullable property 'Summary' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L5
Non-nullable property 'Name' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L6
Non-nullable property 'DefaultValue' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L7
Non-nullable property 'Type' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L8
Non-nullable property 'Description' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/DataGrid/BitDataGridDemo.razor#L6
'BitDataGridDemo.HttpClient' hides inherited member 'AppComponentBase.HttpClient'. Use the new keyword if hiding was intended.
build api + blazor web
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L5
Non-nullable property 'Name' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L6
Non-nullable property 'DefaultValue' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L7
Non-nullable property 'Type' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentPropertyDetailsDto.cs#L8
Non-nullable property 'Description' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L5
Non-nullable property 'Name' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L6
Non-nullable property 'Parameters' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L7
Non-nullable property 'Output' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build api + blazor web: src/BlazorUI/Demo/Bit.BlazorUI.Demo.Shared/Dtos/ComponentMethodDetailsDto.cs#L8
Non-nullable property 'Summary' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the property as nullable.
build blazor hybrid (windows): src/BlazorUI/Bit.BlazorUI/Components/Buttons/BitMenuButton/BitMenuButton.razor.cs#L10
Non-nullable field 'selectedItem' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the field as nullable.
build blazor hybrid (windows): src/BlazorUI/Bit.BlazorUI/Components/Persona/BitPersona.razor.cs#L303
The switch expression does not handle some values of its input type (it is not exhaustive) involving an unnamed enum value. For example, the pattern '(Bit.BlazorUI.BitPersonaSize)9' is not covered.
build blazor hybrid (windows): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/DataGrid/BitDataGridDemo.razor#L6
'BitDataGridDemo.HttpClient' hides inherited member 'AppComponentBase.HttpClient'. Use the new keyword if hiding was intended.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (windows): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Dropdown/_BitDropdownItemDemo.razor#L328
Argument of type 'ICollection<string>' cannot be used for parameter '__arg10' of type 'ICollection<string?>' in 'void TypeInference.CreateBitDropdown_27<BitDropdownItem<string>, string?>(RenderTreeBuilder __builder, int seq, int __seq0, bool __arg0, int __seq1, bool __arg1, int __seq2, bool __arg2, int __seq3, string __arg3, int __seq4, string __arg4, int __seq5, ICollection<BitDropdownItem<string>> __arg5, int __seq6, bool __arg6, int __seq7, bool __arg7, int __seq8, Func<BitDropdownItem<string>, string?> __arg8, int __seq9, EventCallback<BitDropdownItem<string>> __arg9, int __seq10, ICollection<string?> __arg10, int __seq11, EventCallback<ICollection<string?>> __arg11, int __seq12, Expression<Func<ICollection<string?>>> __arg12)' due to differences in the nullability of reference types.
build blazor hybrid (windows): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Calendar/BitCalendarDemo.razor.cs#L689
The field 'BitCalendarDemo.example1CsharpCode' is assigned but its value is never used
build blazor hybrid (iOS-macOS): src/BlazorUI/Bit.BlazorUI/Components/Buttons/BitMenuButton/BitMenuButton.razor.cs#L10
Non-nullable field 'selectedItem' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the field as nullable.
build blazor hybrid (iOS-macOS): src/BlazorUI/Bit.BlazorUI/Components/Persona/BitPersona.razor.cs#L303
The switch expression does not handle some values of its input type (it is not exhaustive) involving an unnamed enum value. For example, the pattern '(Bit.BlazorUI.BitPersonaSize)9' is not covered.
build blazor hybrid (iOS-macOS): src/BlazorUI/Bit.BlazorUI/Components/Inputs/Dropdown/BitDropdown.razor.cs#L1289
Possible null reference argument for parameter 'arg' in 'TValue Func<TItem, TValue>.Invoke(TItem arg)'.
build blazor hybrid (iOS-macOS): src/BlazorUI/Bit.BlazorUI/Components/Inputs/Dropdown/BitDropdown.razor.cs#L1306
Possible null reference argument for parameter 'arg' in 'TValue Func<TItem, TValue>.Invoke(TItem arg)'.
build blazor hybrid (iOS-macOS): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/DataGrid/BitDataGridDemo.razor#L6
'BitDataGridDemo.HttpClient' hides inherited member 'AppComponentBase.HttpClient'. Use the new keyword if hiding was intended.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (iOS-macOS): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Dropdown/_BitDropdownItemDemo.razor#L328
Argument of type 'ICollection<string>' cannot be used for parameter '__arg10' of type 'ICollection<string?>' in 'void TypeInference.CreateBitDropdown_27<BitDropdownItem<string>, string?>(RenderTreeBuilder __builder, int seq, int __seq0, bool __arg0, int __seq1, bool __arg1, int __seq2, bool __arg2, int __seq3, string __arg3, int __seq4, string __arg4, int __seq5, ICollection<BitDropdownItem<string>> __arg5, int __seq6, bool __arg6, int __seq7, bool __arg7, int __seq8, Func<BitDropdownItem<string>, string?> __arg8, int __seq9, EventCallback<BitDropdownItem<string>> __arg9, int __seq10, ICollection<string?> __arg10, int __seq11, EventCallback<ICollection<string?>> __arg11, int __seq12, Expression<Func<ICollection<string?>>> __arg12)' due to differences in the nullability of reference types.
build blazor hybrid (iOS-macOS): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Calendar/BitCalendarDemo.razor.cs#L689
The field 'BitCalendarDemo.example1CsharpCode' is assigned but its value is never used
build blazor hybrid (android): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/DataGrid/BitDataGridDemo.razor#L6
'BitDataGridDemo.HttpClient' hides inherited member 'AppComponentBase.HttpClient'. Use the new keyword if hiding was intended.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android)
The annotation for nullable reference types should only be used in code within a '#nullable' annotations context. Auto-generated code requires an explicit '#nullable' directive in source.
build blazor hybrid (android): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Dropdown/_BitDropdownItemDemo.razor#L328
Argument of type 'ICollection<string>' cannot be used for parameter '__arg10' of type 'ICollection<string?>' in 'void TypeInference.CreateBitDropdown_27<BitDropdownItem<string>, string?>(RenderTreeBuilder __builder, int seq, int __seq0, bool __arg0, int __seq1, bool __arg1, int __seq2, bool __arg2, int __seq3, string __arg3, int __seq4, string __arg4, int __seq5, ICollection<BitDropdownItem<string>> __arg5, int __seq6, bool __arg6, int __seq7, bool __arg7, int __seq8, Func<BitDropdownItem<string>, string?> __arg8, int __seq9, EventCallback<BitDropdownItem<string>> __arg9, int __seq10, ICollection<string?> __arg10, int __seq11, EventCallback<ICollection<string?>> __arg11, int __seq12, Expression<Func<ICollection<string?>>> __arg12)' due to differences in the nullability of reference types.
build blazor hybrid (android): src/BlazorUI/Demo/Client/Bit.BlazorUI.Demo.Client.Core/Pages/Components/Inputs/Calendar/BitCalendarDemo.razor.cs#L689
The field 'BitCalendarDemo.example1CsharpCode' is assigned but its value is never used
build blazor hybrid (android): src/BlazorUI/Bit.BlazorUI/Components/Buttons/BitMenuButton/BitMenuButton.razor.cs#L10
Non-nullable field 'selectedItem' must contain a non-null value when exiting constructor. Consider adding the 'required' modifier or declaring the field as nullable.
build blazor hybrid (android): src/BlazorUI/Bit.BlazorUI/Components/Persona/BitPersona.razor.cs#L303
The switch expression does not handle some values of its input type (it is not exhaustive) involving an unnamed enum value. For example, the pattern '(Bit.BlazorUI.BitPersonaSize)9' is not covered.

Artifacts

Produced during runtime
Name Size
ios-bundle Expired
8.54 MB
server-bundle Expired
80.5 MB
win-exe-bundle Expired
18.5 MB