-- Modification de la méthode de calcul:
-- DROP FUNCTION remocra.calcul_debit_pression_61(int8); -- Si nécessaire lors de l'exécution du patch

CREATE OR REPLACE FUNCTION remocra.calcul_debit_pression_61(id_hydrant bigint)
RETURNS void
LANGUAGE plpgsql
AS $function$

DECLARE
p_anomalie_id integer;
p_rec remocra.hydrant_pibi%ROWTYPE;
p_diametre_id integer;
BEGIN
select * into p_rec from remocra.hydrant_pibi where id = id_hydrant;
-- Suppression des anomalies débit/pression des règles communes
delete from remocra.hydrant_anomalies where hydrant=id_hydrant and anomalies in
(
select id
from remocra.type_hydrant_anomalie
where code
IN(
'PRESSION_INSUFF', 'PRESSION_TROP_ELEVEE', 'PRESSION_DYN_INSUFF',
'PRESSION_DYN_INSUFF_NC', 'PRESSION_DYN_TROP_ELEVEE',
'DEBIT_INSUFF_NC', 'DEBIT_TROP_ELEVE', 'DEBIT_INSUFF'
)
);

--------------------- Pour les débits
-- DIAM 80
SELECT id into p_diametre_id FROM remocra.type_hydrant_diametre WHERE code LIKE 'DIAM80';

if ((p_rec.debit < 30) AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.debit > 90 AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_TROP_ELEVE';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
end if;

--DIAM 100
SELECT id into p_diametre_id FROM remocra.type_hydrant_diametre WHERE code LIKE 'DIAM100';

if ((p_rec.debit < 30) AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.debit < 60 AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF_NC';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.debit > 130 AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_TROP_ELEVE';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
end if;

--DIAM 150
SELECT id into p_diametre_id FROM remocra.type_hydrant_diametre WHERE code LIKE 'DIAM150';

if ((p_rec.debit < 30) AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.debit < 120 AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF_NC';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.debit > 180 AND p_rec.diametre = p_diametre_id) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_TROP_ELEVE';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
end if;

--------------------- Pour les pressions
if (p_rec.pression_dyn < 1) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_DYN_INSUFF_NC';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.pression_dyn > 8) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_DYN_TROP_ELEVEE';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
end if;

if (p_rec.pression < 1) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.pression > 8) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_TROP_ELEVEE';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.pression is null and p_rec.debit is null) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_DYN_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
elsif (p_rec.pression_dyn is null and p_rec.debit is null) then
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'DEBIT_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
select id into p_anomalie_id from remocra.type_hydrant_anomalie where code = 'PRESSION_DYN_INSUFF';
insert into remocra.hydrant_anomalies (hydrant,anomalies) values (p_rec.id, p_anomalie_id);
end if;

perform remocra.calcul_indispo(p_rec.id);
END;
$function$
;

SELECT remocra.calcul_debit_pression_61(id) FROM remocra.hydrant_pibi;