Skip to content

Commit

Permalink
feat(docs): Update procedure in regards to trailer connection (#81)
Browse files Browse the repository at this point in the history
Add steps to confirm trailer connection and what to do in case of issues
  • Loading branch information
gteufelberger authored Jun 22, 2024
1 parent d7c0d63 commit 3d506e4
Showing 1 changed file with 28 additions and 2 deletions.
30 changes: 28 additions & 2 deletions src/dacs-sw/control-station-installation/sections/installation.tex
Original file line number Diff line number Diff line change
Expand Up @@ -62,8 +62,8 @@

\procedureItem{
Connect the 100m ethernet cable to the ethernet switch in DACS Box and to the mission control PC.
\\
(Check that in the upper right corner when you click on the WLAN symbol it says 'Wired connected')
% \\
% (Check that in the upper right corner when you click on the WLAN symbol it says 'Wired connected')
}

\procedureItem{
Expand All @@ -74,6 +74,20 @@
Grab newest config file from sharepoint
}

\procedureItem{
Ask TC to confirm that it's ok to connect the power cable for the trailer.
\\
Once confirmed, connect it.
}

\procedureItem{
Check that there's a connection to the trailer.
\\
The LED on the switch should light up.
\\
If it does not, check the cables at every connector.
}

\procedureItem{
Launch system by running in terminal:
\\
Expand Down Expand Up @@ -152,4 +166,16 @@
\item set buffer in upper left corner to 600 to set the window size to 10 minutes
\end{itemize}
}

\procedureItem{
Confirm that you get valid data read outs from the trailer.
}

\procedureItem{
Confirm that you get a live camera feed.
}

\procedureItem{
Good luck on your firing $<$3
}
\end{tabularx}

0 comments on commit 3d506e4

Please sign in to comment.