Releases: Trunks1982/Daikin-Rotex-HPSU-CAN-Seriell

2024.11.2

18 Nov 18:33
Compare
Choose a tag to compare

New sensors and settings

energy_cooling:
  name: Energie Kühlung
total_electrical_energy:
  name: Elektrische Energie Gesamt
external_temp_sensor:
  name: SKonfig T-Außen
energy_saving_mode:
  name: ES mode

Features and Fixes

  • Fixed optimized_defrosting when temperature_antifreeze is not used
  • Fixed optimized_defrosting when switching back from Warmwasserbereitung
  • Fixed negative temperature_outside sensor values

2024.11.1

01 Nov 13:41
Compare
Choose a tag to compare

New sensors and settings

temperature_antifreeze:
  name: T-Frostschutz

Features and Fixes

  • Fix WW bereiten when WW Soll is a Number
  • Add misbehavior detection for 3UV-DHW and 3UV-BPV
  • Disable temperature_antifreeze when optimized_defrosting is enabled
  • Disable optimized_defrosting when temperature_antifreeze changes
  • Fix optimized defrosting

New controll settings for misbehavior detection

daikin_rotex_can:
  max_spread_tvbh_tv: 4
  max_spread_tvbh_tr: 4

These settings are required if Tv, Tr or TvBH measure inaccurately, leading to error messages even though the pump itself is functioning well.

2024.09.6

23 Sep 13:46
Compare
Choose a tag to compare

New sensors and settings

project_git_hash:
  name: Project Git Hash
optimized_defrosting:
  name: Abtau-Optimierung
heating_limit_day:
  name: Heizgrenze Tag
heating_limit_night:
  name: Heizgrenze Nacht
flow_temperature_night:
  name: T Vorlauf Nacht
max_target_flow_temp:
  name: Max T-Vorlauf
min_target_flow_temp:
  name: Min T-Vorlauf
max_heating_temperature:
  name: Max Temp Heizung
supply_temperature_adjustment_heating:
  name: Anpassung T-VL Heizen
supply_temperature_adjustment_cooling:
  name: Anpassung T-VL Kühlen
1_dhw:
  name: 1 x Warmwasser
hp_hyst_tdhw:
  name: WPHyst TDHW
delay_time_for_backup_heating:
  name: Wartezeit BOH

Features and Fixes

  • When switching settings on the HP control panel, all sensors now update immediately
  • Fixed an issue where some sensors displayed incorrect values when a RoCon G1 was connected
  • Increased the accuracy of flow_temperature_day and flow_temperature_night settings to 0.1

2024.09.5

19 Sep 09:43
Compare
Choose a tag to compare

New sensors and settings

flow_rate_min:
  name: Durchfluss Min
flow_rate_setpoint:
  name: Durchfluss Soll
flow_rate_calc:
  name: DurchflussBer
flow_rate_hyst:
  name: Durchfluss Hyst

Features and fixes

  • All numerical values can now be changed to combos. See: T-WW-Soll and Raumsoll examples in options.yaml
  • Spreizung HZ and Spreizung WW and Flüsterbetrieb is now adjustable
  • Show --- for Ext when Smart Grid or SG Modus are disabled
  • Fixed device_class and unit_of_measurement warnings in HA log for percent and flow sensors

2024.09.4

15 Sep 14:09
Compare
Choose a tag to compare

Added the following new sensors / numbers / selects:

function_ehs:
  name: Funktion EHS
ch_support:
  name: HZ Unterstützung
power_dhw:
  name: Leistung WW
power_ehs_1:
  name: Leistung EHS Stufe 1
power_ehs_2:
  name: Leistung EHS Stufe 2
power_biv:
  name: Leistung BIV
tdiff_dhw_ch:
  name: TDiff-WW HZU
electric_heater:
  name: Heizstäbe
ext:
  name: Ext

Additional features and fixes:

  • Remove 0x prefix from messages in log
  • Fix esp crash when thermal_power sensor was not used

2024.09.3

15 Sep 14:00
Compare
Choose a tag to compare

Added the following new sensors:

antileg_temp:
    name: AntilegTemp
circulation_interval_on:
    name: ZirkInterval An
circulation_interval_off:
    name: ZirkInterval Aus
tdiff_dhw_ch:
  name: TDiff-WW HZU
dhw_off_time:
  name: WW Sperrzeit
max_dhw_loading:
  name: Max WW Ladezeit
t_dhw_1_min:
  name: Schaltschwelle TDHW
antileg_day:
    name: AntilegTag
circulation_with_dhw_program:
  name: Zirk mit WW-Prog
outdoor_unit:
  name: Aussengerät
indoor_unit:
  name: Innengerät

Additional features and fixes:

  • Added dump button (writes configuration to the log)
  • Fixed handling of messages initiated by RoCon
  • Fixed missing requests at startup

2024.09.2

15 Sep 13:59
Compare
Choose a tag to compare

Breaking changes:

Rename spreizung_mod_hz to delta_temp_ch
Rename spreizung_mod_ww to delta_temp_dhw
Rename water_flow to flow_rate

2024.09.1

15 Sep 13:57
Compare
Choose a tag to compare

Added the following new sensors:

qboh:
  name: EHS für DHW
qch:
  name: Energie Heizung
quiet:
  name: Flüsterbetrieb
t_ext:
  name: T-Aussen
t_hs:
  name: T-WE

Added new text controls (development helpers):

log_filter:  # Allows textual filtering of log outputs
  name: Log Filter
custom_request:  # Allows byte sequences to be sent to the heat pump (facilitates the development of new entities)
  name: Custom Request

kleine Verbesserungen

02 Jun 10:26
16b80c5
Compare
Choose a tag to compare

SG Modus, Smart Grid hinzugefügt

kleine Optimierung

01 Apr 07:30
2fe4242
Compare
Choose a tag to compare

Anzeige der RaumSoll Einstellung, Heizkurven Einstellung und WW Einstellung