Linear Heater Control

This config allows you to linearly control the heating or cooling of a heater in Klipper.

The most common use case would be to control the temperature of the heated bed during cooling to prevent warping in materials such as ABS/ASA/etc. The bed temperature can be slowly/linearly cooled over time allowing the material to release internal stresses and cool uniformly.

Without Linear Heater Control With Linear Heater Control (1°C/min)
36°C Temperature Drop in 10 Minutes 10°C Temperature Drop in 10 Minutes

How To Set-Up

I believe the easiest method to manually copy the config file onto your Klipper host using your front-end:

  • Download Linear_Heater_Control.cfg from this GitHub repository.
  • Open your Klipper Front-End (ie. Fluidd or Mainsail) and navigate to your configuration section.
  • Paste/Upload/Drag-Drop the downloaded file Linear_Heater_Control.cfg into your config folder.
  • Place the following somehwere in an included Klipper cfg file (ie. printer.cfg):
    [include Linear_Heater_Control.cfg]
  • Done! You can now call the macro using LINEAR_HEATER_CONTROL

Macro Information

Macro Name:

LINEAR_HEATER_CONTROL

Macro Arguments:

Argument Unit Type Default Description
HEATER n/a string heater_bed The name of the heater you would like to control (ie. heater_bed or extruder).
TARGET °C float 0 The desired final temperature. This is what the heater will be set to when the macro ends control.
TRANSITION_RATE °C/min float 1.3 The desired rate of temperature change of the heater (if achievable).
COOLING_ABORT_DELTA °C float 1.5 The control will terminate early if TRANSITION_RATE exceeds the natural cooling rate (measured temp - control temp > COOLING_ABORT_DELTA). Only during cooling.
REFRESH_TIME sec. float 5 Duration of time between control actions (ie. 5s --> 12Hz update freq.)

Examples:

Calling the macro with default parameters:

LINEAR_HEATER_CONTROL

Calling the macro with a custom transition rate:

LINEAR_HEATER_CONTROL TRANSITION_RATE=1.0

Calling the macro with a custom heater name and transition rate:

LINEAR_HEATER_CONTROL HEATER="extruder2" TRANSITION_RATE=1.0

Using the macro in your END_GCODE (example):

...
SET_HEATER_TEMPERATURE HEATER=extruder TARGET=0     ;Turn off the extruder heater
LINEAR_HEATER_CONTROL                               ; Controlled Cooldown Bed
M107                                                ; turn off fan
G90                                                 ; absolute positioning
G0 X5 F3600                                         ; park nozzle
M84                                                 ; Turn off steppers
...

Pending Updates:

  • Improved detection/alert for invalid input arguements (ie invalid heater names)
  • Improved Installation instructions using SSH + automatic updates with moonraker

Disclaimer

Warning

Use this macro responsibly.

YOU are responsible for ensuring the safety of your printer and the commanded temperatures.

Do not operate your printer un-attended.