Skip to content

Commit

Permalink
Update README.md
Browse files Browse the repository at this point in the history
  • Loading branch information
mstegen authored Feb 10, 2022
1 parent cf96654 commit b9b10ca
Showing 1 changed file with 11 additions and 10 deletions.
21 changes: 11 additions & 10 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,13 +3,14 @@ Sensorbox2 measures the current(A) and current direction for up to three phases
It can also receive these measurements directly from a (D)SMR5 smart meters P1 port.
These measurements are then sent every two seconds to the connected SmartEVSE(s).

The Sensorbox2 uses a PIC microcontroller which currently does all the processing. It takes the measurements from the CT inputs and P1 port and can send the data over the RS485 bus.
It will be programmed initially by the ESP32 module. At powerup the ESP32 looks for a Sensorbox2.hex file in the /data folder and, when found programs the PIC18F26K40 microcontroller.
The Sensorbox2 uses a PIC microcontroller which does the CT measurements and sends this information to the ESP32.
The ESP32 processes the P1 port (Smart Meter connection) data and RS485 communication to the SmartESVE.
The PIC will be (re)programmed by the ESP32 module. At powerup the ESP32 looks for a PIC18F26K40.hex file in the /data folder and, when found programs the PIC18F26K40 microcontroller.

Please note that this also means that the PIC has control over the RS485 bus. If you want full controll, keep the PIC in reset by holding the PIC reset line low.
This code uses Arduino core 2.0.2 as it has critical bug fixes, and much better Uart drivers.
Modbus handling is done with the eModbus library.
The platformio.ini file should install all necessary libraries automatically.

I'll release a version of the PIC firmware soon that will only do the CT measurements, and will not use the RS485 bus, nor use the P1 port.
On this version the ESP32 will handle everything else.

## Modbus Registers

Expand All @@ -20,10 +21,10 @@ Input Registers (FC=04)(Read Only):

Register Register
Address length (16 bits)
0x0000 1 Sensorbox version 2 = 0x0014 (2 lsb mirror the 3/4 Wire and Rotation configuration data)
0x0015 = 4 wire, CCW rotation
0x0016 = 3 wire, CW rotation
0x0017 = 3 wire, CCW rotation
0x0000 1 Sensorbox version 2 = 0x0114 (2 lsb mirror the 3/4 Wire and Rotation configuration data)
0x0115 = 4 wire, CCW rotation
0x0116 = 3 wire, CW rotation
0x0117 = 3 wire, CCW rotation
0x0001 1 DSMR Version(MSB),CT's or P1(LSB) 0x3283 = DSMR version 50, P1 port connected (0x80) CT's Used (0x03)
0x0002 2 Volts L1 (32 bit floating point), Smartmeter P1 data
0x0004 2 Volts L2 (32 bit floating point), Smartmeter P1 data
Expand All @@ -35,7 +36,7 @@ Input Registers (FC=04)(Read Only):
0x0010 2 Amps L2 (32 bit floating point), CT input 2
0x0012 2 Amps L3 (32 bit floating point), CT input 3
when sensorbox software version >= 0x01xx, the following extra registers are available
with sensorbox software version >= 0x01xx, the following extra registers are available

0x0014 1 WiFi Connection Status xxxxxACL xxxxxxWW = WiFi mode (00=Wifi Off, 01=On, 10=portal started)
||\_ Local Time Set
Expand Down

0 comments on commit b9b10ca