46 changes: 22 additions & 24 deletions docs/electrode_files/Abbott_Active_Tip.rst
Original file line number Diff line number Diff line change
Expand Up @@ -2,53 +2,51 @@
Abbott St. Jude Active Tip
==========================

* Manufacturer: Abbott / St. Jude
* Products: Abbott / St. Jude 6142- 6145, Abbott / St. Jude 6146-6149
* Models: 6142, 6143, 6144, 6145, 6146, 6147, 6148, 6149
* **Manufacturer:** `Abbott <https://www.abbott.com/>`_
* **Products:** Abbott / St. Jude 6142-6145, Abbott / St. Jude 6146-6149
* **Models:** 6142, 6143, 6144, 6145, 6146, 6147, 6148, 6149

Source documentation: `Source <https://manuals.sjm.com/~/media/manuals/product-manual-pdfs/8/6/86a4f8d2-35ab-42f8-9fa3-a53c22dda2dd.pdf>`_.
The source documentation also contains information
about :doc:`Abbot St. Jude Directed <./Abbott_StJude_Directed>`.
Source documentation: `Source <https://manuals.sjm.com/~/media/manuals/product-manual-pdfs/8/6/86a4f8d2-35ab-42f8-9fa3-a53c22dda2dd.pdf>`_.
The source documentation also contains information about :doc:`Abbott St. Jude Directed <./Abbott_StJude_Directed>`.

-----------------------------------
St. Jude Traditional Lead 6142-6145
-----------------------------------

.. image:: electrode_pictures/St-Jude-6142-6145.svg

:alt: Illustration of St. Jude Traditional Lead 6142-6145

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~
* tip_length = 3.0
* contact_length = 1.5
* contact_spacing = 1.5
* lead_diameter = 1.4
* total_length = 400.0

* tip_length = 3.0
* contact_length = 1.5
* contact_spacing = 1.5
* lead_diameter = 1.4
* total_length = 400.0

-----------------------------------
St. Jude Traditional Lead 6146-6149
-----------------------------------

.. image:: electrode_pictures/St-Jude-6146-6149.svg

.. image:: electrode_pictures/St-Jude-6146-6149.svg
:alt: Illustration of St. Jude Traditional Lead 6146-6149

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~
* tip_length = 3.0
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.4
* total_length = 400.0

.. note:: The total length does not influence the computational domain that's why all the above electrodes are modeled at 400mm
* tip_length = 3.0
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.4
* total_length = 400.0

----
Code
----

.. autoclass:: ossdbs.electrodes.abbott_stjude.AbbottStJudeActiveTipModel
:members:
:show-inheritance:
:members:
:show-inheritance:
45 changes: 22 additions & 23 deletions docs/electrode_files/Abbott_StJude_Directed.rst
Original file line number Diff line number Diff line change
@@ -1,53 +1,52 @@
========================
Abbott St. Jude Directed
Abbott St. Jude Directed
========================

* Manufacturer: Abbott / St. Jude
* Products: Abbott / St. Jude 6172, Abbott / St. Jude 6173
* Models: 6172, 6173
* **Manufacturer:** `Abbott <https://www.abbott.com/>`_
* **Products:** Abbott / St. Jude 6172, Abbott / St. Jude 6173
* **Models:** 6172, 6173

Source documentation: `Source <https://manuals.sjm.com/~/media/manuals/product-manual-pdfs/8/6/86a4f8d2-35ab-42f8-9fa3-a53c22dda2dd.pdf>`_.
The source documentation also contains information
about :doc:`Abbot St. Jude Active Tip <./Abbott_Active_Tip>`
Source documentation: `Source <https://manuals.sjm.com/~/media/manuals/product-manual-pdfs/8/6/86a4f8d2-35ab-42f8-9fa3-a53c22dda2dd.pdf>`_.
The source documentation also contains information about :doc:`Abbott St. Jude Active Tip <./Abbott_Active_Tip>`.

-------------------------------------------------
St. Jude Medical Infinity ™ Directional Lead 6172
-------------------------------------------------

.. image:: electrode_pictures/Abott_St_Jude_6172.svg

:alt: Illustration of Abbott St. Jude Infinity Directional Lead 6172

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~

* tip_length = 1.5
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.29
* total_length = 400.0

* tip_length = 1.0
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.29
* total_length = 400.0

-------------------------------------------------
St. Jude Medical Infinity ™ Directional Lead 6173
-------------------------------------------------

.. image:: electrode_pictures/Abott_St_Jude_6173.svg

.. image:: electrode_pictures/Abott_St_Jude_6173.svg
:alt: Illustration of Abbott St. Jude Infinity Directional Lead 6173

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~
* tip_length = 1.5
* contact_length = 1.5
* contact_spacing = 1.5
* lead_diameter = 1.29
* total_length = 400.0

* tip_length = 1.0
* contact_length = 1.5
* contact_spacing = 1.5
* lead_diameter = 1.29
* total_length = 400.0

----
Code
----

.. autoclass:: ossdbs.electrodes.abbott_stjude.AbbottStJudeDirectedModel
:members:
:show-inheritance:
:members:
:show-inheritance:
50 changes: 23 additions & 27 deletions docs/electrode_files/Boston_Scientific_Cartesia.rst
Original file line number Diff line number Diff line change
Expand Up @@ -2,62 +2,58 @@
Boston Scientific Cartesia
==========================

* Manufacturer: Boston Scientific
* Product: Boston Scientific Cartesia
* Serial name: CartesiaX, CartesiaHX
* **Manufacturer:** `Boston Scientific <https://www.bostonscientific.com/en-US/home.html>`_
* **Product:** Boston Scientific Cartesia
* **Serial name:** CartesiaX, CartesiaHX

Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_.
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_.
Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_


The source documentation also contains information about
:doc:`Boston Scientific Directed Lead (DB-2202) <./Boston_Scientific_Vercise_Directed>`.
The source documentation also contains information about :doc:`Boston Scientific Directed Lead (DB-2202) <./Boston_Scientific_Vercise_Directed>`.

---------------------------
Boston Scientific CartesiaX
---------------------------


~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~

* tip_length = 1.1
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.3
* total_length = 450.0
* contacts_skipped = 5.0
* tip_length = 1.1
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.3
* total_length = 450.0
* contacts_skipped = 5.0

----
Code
----

.. autoclass:: ossdbs.electrodes.boston_scientific_cartesia.BostonScientificCartesiaXModel
:members:
:show-inheritance:
:members:
:show-inheritance:

----------------------------
Boston Scientific CartesiaHX
----------------------------


~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
~~~~~~~~~~~~~~~~~~~~~~~

* tip_length = 1.1
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.3
* total_length = 450.0
* contacts_skipped = 7.0
* tip_length = 1.1
* contact_length = 1.5
* contact_spacing = 0.5
* lead_diameter = 1.3
* total_length = 450.0
* contacts_skipped = 7.0

----
Code
----

.. autoclass:: ossdbs.electrodes.boston_scientific_cartesia.BostonScientificCartesiaHXModel
:members:
:show-inheritance:
:members:
:show-inheritance:
21 changes: 10 additions & 11 deletions docs/electrode_files/Boston_Scientific_Vercise.rst
Original file line number Diff line number Diff line change
Expand Up @@ -2,23 +2,22 @@
Boston Scientific Vercise
=========================

* Manufacturer: Boston Scientific
* Product: Boston Scientific Standard Lead
* Serial name: DB-2201
* **Manufacturer:** `Boston Scientific <https://www.bostonscientific.com/en-US/home.html>`_
* **Product:** Boston Scientific Standard Lead
* **Serial name:** DB-2201

Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_.
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_.
Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_

The source documentation also contains information about
:doc:`Boston Scientific Directed Lead (DB-2202) <./Boston_Scientific_Vercise_Directed>`.
The source documentation also contains information about :doc:`Boston Scientific Directed Lead (DB-2202) <./Boston_Scientific_Vercise_Directed>`.

---------------------------------------
Boston Scientific Standard Lead DB-2201
---------------------------------------

.. image:: electrode_pictures/Boston-Scientific-Vercise.svg

:alt: Illustration of Boston Scientific Standard Lead DB-2201

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
Expand All @@ -35,5 +34,5 @@ Code
----

.. autoclass:: ossdbs.electrodes.boston_scientific_vercise.BostonScientificVerciseModel
:members:
:show-inheritance:
:members:
:show-inheritance:
22 changes: 11 additions & 11 deletions docs/electrode_files/Boston_Scientific_Vercise_Directed.rst
Original file line number Diff line number Diff line change
@@ -1,23 +1,23 @@
==================================
Boston Scientific Vercise Directed
==================================
* Manufacturer: Boston Scientific
* Product: Boston Scientific Directional Lead
* Serial name: DB-2202

Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_.
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_.
* **Manufacturer:** `Boston Scientific <https://www.bostonscientific.com/en-US/home.html>`_
* **Product:** Boston Scientific Directional Lead
* **Serial name:** DB-2202

The source documentation also contains information about
:doc:`Boston Scientific Standard Lead (DB-2201) <./Boston_Scientific_Vercise>`.
Source documentation:
`Source PDF <https://www.bostonscientific.com/content/dam/elabeling/nm/92495783-02_Vercis_TM-DBS_Systems_Surgical_Implant_Manual_multi-OUS_s.pdf>`_
`Source Webpage <https://www.bostonscientific.com/en-US/products/deep-brain-stimulation-systems/vercise-genus-dbs-system/leads.html>`_

The source documentation also contains information about :doc:`Boston Scientific Standard Lead (DB-2201) <./Boston_Scientific_Vercise>`.

------------------------------------------
Boston Scientific Directional Lead DB-2202
------------------------------------------

.. image:: electrode_pictures/Boston-Scientific-Vercise-directed.svg

:alt: Illustration of Boston Scientific Directional Lead DB-2202

~~~~~~~~~~~~~~~~~~~~~~~
Default Parameters (mm)
Expand All @@ -34,5 +34,5 @@ Code
----

.. autoclass:: ossdbs.electrodes.boston_scientific_vercise.BostonScientificVerciseDirectedModel
:members:
:show-inheritance:
:members:
:show-inheritance:
Loading
Loading