Provided under MIT license
Supports ClearOne CONVERGE Pro 2 evices
Setting | Value |
---|---|
Delimiter | "\n" |
Default Baud | 57600 |
Data Bits | 8 |
Stop Bits | 1 |
Parity | none |
Flow Control | none |
Telnet Port | 23 |
com
tcpIp
Type: convergepro2dsp
{
"key": "dsp1",
"name": "ClearOne Converge Pro 2",
"type": "convergePro2",
"group": "plugin",
"properties": {
"control": {
"method": "tcpip",
"controlPortDevKey": "processor",
"controlPortNumber": 1,
"comParams": {
"protocol": "RS232",
"baudRate": 57600,
"dataBits": 8,
"stopBits": 1,
"parity": "None",
"hardwareHandshake": "None",
"softwareHandshake": "None"
},
"tcpSshProperties": {
"address": "10.0.0.194",
"port": 23,
"username": "admin",
"password": "password",
"autoReconnect": true,
"autoReconnectIntervalMs": 10000
}
},
"communicationMonitorProperties": {
"pollInterval": 60000,
"timeToWarning": 180000,
"timeToError": 300000
},
"boxName": "DSP1"
}
}
Refers to the end point block corresponding to some functionality of the endpoint, for level control blocks the most commonly used value is:
"blockName": "LEVEL"
Parameter names will vary based on the Block Numbers (BN) used to configure the blockName
property. The most commonly used values are:
"levelParameter": "GAIN"
"muteParameter": "MUTE"
{
"properties": {
"levelControlBlocks": {
"fader-main": {
"label": "Main",
"channelName": "SPKR_ZN_1",
"blockName": "LEVEL",
"levelParameter": "GAIN",
"muteParameter": "MUTE",
"disabled": false,
"hasLevel": true,
"hasMute": true,
"isMic": false,
"useAbsoluteValue": false,
"unmuteOnVolChange": true
}
}
}
}
{
"properties": {
"presets": {
"preset1": {
"label": "System On",
"preset": "1"
},
"preset2": {
"label": "System Off",
"preset": "2"
},
"preset3": {
"label": "Default Levels",
"preset": "3"
}
}
}
}
"preset"
is the name of the macro to run, the name is case sensitive.
{
"properties": {
"dialers": {
"dialer1": {
"label": "Dialer",
"channelName": "VOIP1",
"isVoip": true,
"clearOnHangup": true
}
}
}
}
isVoip
will change the command sent to include the endpointType
UA
.
i.e. EP UA {channelName} KEY KEY_CALL {dialString}
{
"key": "dsp1-bridge",
"name": "DSP Bridge",
"group": "api",
"type": "eiscApiAdvanced",
"properties": {
"control": {
"method": "ipidTcp",
"tcpSshProperties": {
"address": "127.0.0.2",
"port": 0
},
"ipid": "a2"
},
"devices": [
{
"deviceKey": "dsp1",
"joinStart": 1
}
]
}
}
{
"key": "dsp1-bridge",
"name": "DSP Bridge",
"group": "api",
"type": "vcEiscApiAdvanced",
"properties": {
"control": {
"ipid": "d1",
"method": "ipid",
"roomId": "ROOM01SIMPL"
},
"devices": [
{
"deviceKey": "dsp-dialer1",
"joinStart": 1
}
]
}
}
The selection below documents the digital, analog, and serial joins used by the SiMPL EISC. Update the bridge join maps as needed for the plugin being developed.
Join Number | Join Span | Description | Type | Capabilities |
---|---|---|---|---|
1 | 1 | Is Online | Digital | FromSIMPL |
101 | 100 | Preset Recall | Digital | FromSIMPL |
201 | 200 | ControlTag Visible | Digital | FromSIMPL |
401 | 200 | ControlTag Mute Toggle | Digital | ToFromSIMPL |
601 | 200 | ControlTag Mute On | Digital | ToSIMPL |
801 | 200 | ControlTag Mute Off | Digital | ToSIMPL |
1001 | 200 | ControlTag Volume Up | Digital | FromSIMPL |
1201 | 200 | ControlTag Volume Down | Digital | FromSIMPL |
3100 | 1 | Call Incoming | Digital | ToSIMPL |
3106 | 1 | Answer Incoming Call | Digital | FromSIMPL |
3107 | 1 | End Call | Digital | FromSIMPL |
3110 | 10 | Keypad Digits 0-9 | Digital | FromSIMPL |
3120 | 1 | Keypad * | Digital | FromSIMPL |
3121 | 1 | Keypad # | Digital | FromSIMPL |
3122 | 1 | Keypad Clear | Digital | FromSIMPL |
3123 | 1 | Keypad Backspace | Digital | FromSIMPL |
3124 | 1 | Keypad Dial and Feedback | Digital | ToFromSIMPL |
3125 | 1 | Auto Answer On and Feedback | Digital | ToFromSIMPL |
3126 | 1 | Auto Answer Off and Feedback | Digital | ToFromSIMPL |
3127 | 1 | Auto Answer Toggle and On Feedback | Digital | ToFromSIMPL |
3129 | 1 | On Hook Set and Feedback | Digital | ToFromSIMPL |
3130 | 1 | Off Hook Set and Feedback | Digital | ToFromSIMPL |
3132 | 1 | Do Not Disturb Toggle and Feedback | Digital | ToFromSIMPL |
3133 | 1 | Do Not Disturb On Set and Feedback | Digital | ToFromSIMPL |
3134 | 1 | Do Not Disturb Of Set and Feedback | Digital | ToFromSIMPL |
Join Number | Join Span | Description | Type | Capabilities |
---|---|---|---|---|
1 | 1 | Device communication monitor status feedback | Analog | ToSIMPL |
2 | 1 | Device socket status feedback | Analog | ToSIMPL |
201 | 200 | ControlTag Volume | Analog | ToFromSIMPL |
401 | 200 | ControlTag Type | Analog | ToSIMPL |
3100 | 1 | Call State Feedback | Analog | ToSIMPL |
Join Number | Join Span | Description | Type | Capabilities |
---|---|---|---|---|
1 | 1 | Device Name | Serial | ToSIMPL |
101 | 100 | Preset Name | Serial | ToSIMPL |
201 | 200 | Channel Name | Serial | ToSIMPL |
3100 | 1 | Dial String Send and Feedback | Serial | ToFromSIMPL |
3101 | 1 | Dialer Label | Serial | ToSIMPL |
3102 | 1 | Last Number Dialed Feedback | Serial | ToSIMPL |
3104 | 1 | Caller ID Number | Serial | ToSIMPL |
3105 | 1 | Caller ID Name | Serial | ToSIMPL |
3106 | 1 | This Line's Number | Serial | ToSIMPL |
devjson:1 {"deviceKey":"dsp1", "methodName":"SetDebugLevels", "params":[2]}