98 changes: 49 additions & 49 deletions config/aeotec/zw100.xml

Large diffs are not rendered by default.

17 changes: 11 additions & 6 deletions config/aeotec/zw141.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@ Aeotec ZW141 Nano Shutter, based on Engineering Spec 8/22/2019
Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
-->
<Product Revision="7" xmlns="https://github.com/OpenZWave/open-zwave">
<Product Revision="8" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0086:008D:0103</MetaDataItem>
<MetaDataItem name="ProductPic">images/aeotec/zw141.png</MetaDataItem>
Expand Down Expand Up @@ -41,7 +41,8 @@ Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
<Entry author="Justin Hammond - [email protected]" date="02 Jun 2019" revision="4">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2953/xml</Entry>
<Entry author="Justin Hammond - [email protected]" date="03 Jun 2019" revision="5">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3075/xml</Entry>
<Entry author="Duy Nguyen - [email protected]" date="16 Feb 2020" revision="6">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/3693/XML</Entry>
<Entry author="Matej Drobnič - [email protected]" date="02 Oct 2020" revision="7">Fixed timing types, Fixed button list types</Entry>
<Entry author="Matej Drobnič - [email protected]" date="02 Oct 2020" revision="7">Fixed timing types, Fixed button list types</Entry>
<Entry author="Jean-François Auger - [email protected]" date="14 Apr 2021" revision="8">Add missing list item for param 22</Entry>
</ChangeLog>
<MetaDataItem id="008D" name="FrequencyName" type="0103">U.S. / Canada / Mexico</MetaDataItem>
<MetaDataItem id="008D" name="Identifier" type="0103">ZW141-A</MetaDataItem>
Expand All @@ -56,8 +57,12 @@ Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
<Item label="Move to 99%" value="1" />
<Item label="Move to 0%" value="2" />
</Value>
<Value genre="config" index="22" label="Motor direction" size="1" type="list" units="" value="2">
<Value genre="config" index="22" label="Motor direction" size="1" type="list" value="0">
<Help>Set to toggle the motor running direction</Help>
<Item label="Shutter/Venetian: Out 1= Up, Out 2= Down" value="0" />
<Item label="Shutter: Out 1= Down, Out 2= Up. Venetian: Out 1= Up, Out 2= Down" value="1" />
<Item label="Shutter: Out 1= Up, Out 2= Down. Venetian: Out 1= Down, Out 2= Up" value="2" />
<Item label="Shutter/Venetian: Out 1= Down, Out 2= Up" value="3" />
</Value>
<Value genre="config" index="34" label="Blade turn time" size="2" max="32767" min="10" type="short" units="0.01 seconds" value="150">
<Help>Set the blade turn time for Venetian mode. Details can be found in section 4.2 of Advanced information Product Manual.</Help>
Expand All @@ -67,9 +72,9 @@ Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
</Value>
<Value genre="config" index="36" label="Enter/exit calibration mode" size="1" type="list" units="" value="0" write_only="true">
<Help>Set to enter/exit calibration mode</Help>
<Item label="Set: Exit calibration mode/Report: Not in calibration mode" value="0" />
<Item label="Set: Enter shutter mode calibration/Report: in shutter mode calibration" value="1" />
<Item label="Set: Enter Venetian mode calibration/Report: in Venetian mode calibration" value="2" />
<Item label="Exit calibration mode/Report: Not in calibration mode" value="0" />
<Item label="Enter shutter mode calibration/Report: in shutter mode calibration" value="1" />
<Item label="Enter Venetian mode calibration/Report: in Venetian mode calibration" value="2" />
</Value>
<Value genre="config" index="37" label="User confirmation for calibration" size="1" type="list" units="" value="0" write_only="true">
<Help>Set user confirmation for calibration</Help>
Expand Down
157 changes: 157 additions & 0 deletions config/aeotec/zwa011.xml
Original file line number Diff line number Diff line change
@@ -0,0 +1,157 @@
<!-- ZWA008 Door Window Sensor 7 -->
<Product Revision="1" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0371:000B:0002</MetaDataItem>
<MetaDataItem name="ProductPic">images/aeotec/zwa011.png</MetaDataItem>
<MetaDataItem id="000B" name="ZWProductPage" type="0002">https://products.z-wavealliance.org/products/3866/</MetaDataItem>
<MetaDataItem name="Name">Door / Window Sensor 7</MetaDataItem>
<MetaDataItem id="000B" name="FrequencyName" type="0002">CEPT (Europe)</MetaDataItem>
<MetaDataItem id="000B" name="Identifier" type="0002">ZWA011-C</MetaDataItem>
<MetaDataItem name="Description">Aeotec Door/ Window Sensor 7 is built on the 700 series Z-Wave technology.
Its a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened.
It also supports connecting external binary sensors with a dry contact through the dry binary contact of the Door/ Window sensor.
Using the latest technology it supports the highest Z-Wave security level of S2 and SmartStart.
</MetaDataItem>
<MetaDataItem name="WakeupDescription">Press the tamper once</MetaDataItem>
<MetaDataItem name="InclusionDescription">1. Open the housing.
2. Remove the battery protection.
3. Press the tamper on the side of the appliance three times quickly.
</MetaDataItem>
<MetaDataItem name="ExclusionDescription">1. Open the housing.
2. Press the tamper on the side of the appliance three times quickly.
</MetaDataItem>
<MetaDataItem name="ResetDescription">Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED
blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the
GREEN LED blinks once.
</MetaDataItem>
<MetaDataItem name="ProductManual">https://aeotec.freshdesk.com/support/solutions/folders/6000237099</MetaDataItem>
<MetaDataItem name="ProductSupport">https://aeotec.freshdesk.com/support/solutions/folders/6000237099</MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond" date="06 July 2020" revision="1">Initial Config File taken from ZWA012</Entry>
<Entry author="GizMoCuz" date="13 April 2021" revision="1">Initial Config File taken from https://help.aeotec.com/support/solutions/articles/6000218764-door-windows-sensor-7-user-guide</Entry>
</ChangeLog>
</MetaData>
<!-- Basic set as report -->
<CommandClass id="32">
<Compatibility>
<SetAsReport>true</SetAsReport>
</Compatibility>
</CommandClass>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value genre="config" index="1" instance="1" label="Operation mode" max="1" min="0" size="1" type="list" value="0">
<Help>Parameter defines device operation mode.</Help>
<Item label="Built-in hall sensor" value="0"/>
<Item label="External Input" value="1"/>
</Value>
<Value genre="config" index="2" instance="1" label="Door/Window or alarm status" max="1" min="0" size="1" type="list" value="0">
<Help>
Parameter defines state of the sensor when the magnet is close.
If the alarm sensor is connected, it determines the output type.
Parameter inactive in external button mode (parameter Operation Mode set to 1).
</Help>
<Item label="Closed" value="0"/>
<Item label="Opened" value="1"/>
</Value>
<Value genre="config" index="3" instance="1" label="Visual LED indications" max="7" min="0" size="1" type="byte" value="7">
<Help>
This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.
Values of parameters may be combined, e.g. 1+2=3 means opening/closing and wake up will be indicated by the visual indicator.
0 - No indications.
1 - Indication of opening/closing status change (input In).
2 - Indication of wake up (1 x click or periodical).
4 - Indication of device tampering.
</Help>
</Value>
<Value genre="config" index="4" instance="1" label="Range test after double click" max="1" min="0" size="1" type="list" value="0">
<Help>
Allows to enable activation of Z-Wave range test with double click of a Tamper Switch 2.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="5" instance="1" label="2nd Association Group triggers" max="1" min="0" size="1" type="list" value="0">
<Help>
Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group.
These commands are sent alternately to switch the devices On and Off.
Commands represent the values of BASIC SET command frames.
Parameter is inactive in external dry-contact mode (parameter Operation Mode set to 1).
</Help>
<Item label="Switch after opening and closing" value="0"/>
<Item label="Switch after opening" value="1"/>
<Item label="Switch after closing" value="2"/>
</Value>
<Value genre="config" index="6" instance="1" label="Commands sent to 2nd Association Group" max="1" min="0" size="1" type="list" value="2">
<Help>
Command frames sent to devices added to the 2nd association group.
</Help>
<Item label="On" value="0"/>
<Item label="Off" value="1"/>
<Item label="On and Off" value="2"/>
</Value>
<Value genre="config" index="7" instance="1" label="Value of ON command frame sent to 2nd Association Group" max="255" min="0" size="1" type="byte" value="255">
<Help>
The value of 0 turns OFF the device, 255 turns it On.
In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level.
</Help>
</Value>
<Value genre="config" index="8" instance="1" label="Value of OFF command frame sent to 2nd Association Group" max="255" min="0" size="1" type="byte" value="0">
<Help>
The value of 0 turns OFF the device, 255 turns it On.
In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level.
</Help>
</Value>
<Value genre="config" index="9" instance="1" label="Time delay of ON command frame" max="32400" min="0" size="2" type="short" units="seconds" value="0">
<Help>
Time period after which On command frame will be sent.
</Help>
</Value>
<Value genre="config" index="10" instance="1" label="Time delay of OFF command frame" max="32400" min="0" size="2" type="short" units="seconds" value="0">
<Help>
Time period after which Off command frame will be sent.
</Help>
</Value>
<Value genre="config" index="11" instance="1" label="Delay of tamper alarm cancellation" max="32400" min="0" size="2" type="short" units="seconds" value="5">
<Help>
Time period after which a tamper alarm will be cancelled.
</Help>
</Value>
<Value genre="config" index="12" instance="1" label="Reporting tamper alarm cancellation" max="1" min="0" size="1" type="list" value="1">
<Help>
Reporting cancellation of tamper alarm to the controller and 5th Association Group.
</Help>
<Item label="Do not send tamper cancellation report" value="0"/>
<Item label="Send tamper cancellation report" value="1"/>
</Value>
<Value genre="config" index="13" instance="1" label="Scene activation functionality" max="1" min="0" size="1" type="list" value="0">
<Help>
The device can trigger scenes via Dry Input Terminal (external contact) using scene IDs assigned to different events.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="14" instance="1" label="Tilt Sensor functionality" max="1" min="0" size="1" type="list" value="1">
<Help>
The device can report Tilt Window events.
This functionality can be disabled if the device is mounted on a door or windows without tilt functionality.To disable tilt detection set the value to 0.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="15" instance="1" label="Tilt sensitivity" max="100" min="0" size="1" type="byte" units="" value="50">
<Help>You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high.
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" label="Lifeline" max_associations="5"/>
<Group index="2" label="Control" max_associations="5"/>
<Group index="3" label="Alarm sensor" max_associations="5"/>
<Group index="4" label="Alarm tamper" max_associations="5"/>
</Associations>
</CommandClass>