Skip to content

Releases: NanoVNA-Saver/nanovna-saver

Short wires waiting II

10 Dec 12:20
8df0019
Compare
Choose a tag to compare

What's Changed

  • MacOS update script by @nechry
  • improoved TDR math again by @EnPassant123
  • region selection when restoring default bands list by @Patronicssaver
  • INSTALLATION.md updates about automated macos build @Patronics
  • allow Touchstone files for calibration by @EnPassant123
  • Library updates, introducing type hinting, refactoring and code cleanups by @zarath

Big thanks to all new contributors!

New Contributors

Full Changelog: v0.6.5...v0.6.8

v0.6.5

27 Oct 08:54
6bcc5ca
Compare
Choose a tag to compare

Pumpkin time again

What's Changed

New Contributors

Full Changelog: v0.6.4...v0.6.5

v0.6.4

25 Jun 10:18
9f0263b
Compare
Choose a tag to compare

What's Changed

New Contributors

Full Changelog: v0.6.3...v0.6.4

Sorry No Binary

17 Nov 11:09
d3216d2
Compare
Choose a tag to compare

What's Changed

Full Changelog: v0.6.2...v0.6.3

Summer rain again

31 Jul 11:48
21e85bd
Compare
Choose a tag to compare

What's Changed

  • Add an UNIX-style manual page
  • PyQt6 fixes
  • Build of MacOS app bundle NanoVNASaver.app
  • option --auto-connect, connect automatically if one device detected
  • Redesign of the About window
  • Jncradiovna3g - support
  • Added support for devices reporting as SV4401A and SV6301A
  • Simplify the in-source launcher script
  • Correct some inconsistencies in the UI
  • Sweep.py: add getters and setters for private fields
  • 3rd party lib updates

New Contributors

Full Changelog: v0.5.5...v0.6.2

Only 64-Bit Binaries since Qt6

For Linux unzip the file and chmod +x the extracted file

Core is spinning

05 Mar 14:01
Compare
Choose a tag to compare

What's Changed

  • Measuring inductor core permeability
  • Bugfixes for calibration data loading and saving
  • Let V2 Devices more time for usb-serial setup
  • Make some windows scrollable

Known Bugs

  • Resonance Analysys crashes Appliction (fixed in main branch)

New Contributors

Full Changelog: https://github.com/NanoVNA-Saver/nanovna-saver/compare/v0.5.4..v0.5.5

Installation Hint

  • If using binaries on Mac or Linux you have to chmod +x nanovna-saver after
    unzipping as executable flags get lost with zip.

Windows build seems to have trouble, don't know if working as lacking windows....

  • Windows binary for 64Bit systems in NanoVNASaver.x64.zip
  • Windows binary for 32Bit systems in NanoVNASaver.x86.zip

Ronna, Quetta - Yeah!

01 Jan 15:38
Compare
Choose a tag to compare

v0.5.4

What's Changed

New Contributors

Full Changelog: v0.5.3...v0.5.4

Installation Hint

  • If using binaries on Mac or Linux you have to chmod +x nanovna-saver after
    unzipping as executable flags get lost with zip.

Windows build seems to have trouble, don't know if working as lacking windows....

  • Windows binary for 64Bit systems in NanoVNASaver.x64.zip
  • Windows binary for 32Bit systems in NanoVNASaver.x86.zip

SHA256sums

c995732fe4a42c50b585ec403005a9467928700ed452b19b45c0bc8f3c149ecf NanoVNASaver.linux_modern.zip
7cb7d739fe98e504cc976f1b0311b4f3d8c9421720ba6607ca50c2f59d769aa9 NanoVNASaver.linux.zip
0a1100d63abacc2b275358542e0a31eca48806a56b6344419b49cd42edf8c879 NanoVNASaver.macos.zip
94ffa26a5a926e8be80073e9d21fc5d3d6ce3c027c5bc54677b7cb96543c4b5d NanoVNASaver.x64.zip

Fall again and again and ... fixed

08 Sep 08:53
6630568
Compare
Choose a tag to compare

v0.5.3

What's Changed

  • Python 3.10 compatibility. (float -> int castings)
  • Fix crash on open in use serial device
  • Use a Defaults module for all settings -
    ignores old .ini settings
  • Refactoring and unifying Chart classes
  • No more automatic update checks (more privacy)
  • Corrected error handling in NanaVNA_V2 code
  • Fix crash with polar chart on python 3.10
  • More float/int issues with current lib versions fixed

Full Changelog: v0.4.0...v0.5.3

Known Issues

  • Can have some new bugs.
  • Trouble with some Hugen Firmware versions. / The alternative japanese firmware
    for S-A-A-2 isn't supported.

Installation Hint

  • If using binaries on Mac or Linux you have to chmod +x nanovna-saver after
    unzipping as executable flags get lost with zip.

  • Windows binary for 64Bit systems in NanoVNASaver.x64.zip

  • Windows binary for 32Bit systems in NanoVNASaver.x86.zip

SHA256sums

022ce517c63d4c7a0c9d70a521cd69233639fa939a9ee10b2e15d666b2509c16 NanoVNASaver.linux.zip
06851cc4c7adb2e9118faefde4b5138dcd5ab0f3237724b581cde928dbf15628 NanoVNASaver.macos.zip
d19671e9399f0c6abcbd0f8a963df1baeb5776b286f9fbf72be42034685a41ab NanoVNASaver.x64.zip
bca52e9a5b8d99538fa4a9dfed7020d6c791b49d55dd3ce9bad01c7730d35d43 NanoVNASaver.x86.zip

April fools'

01 Apr 15:19
582b442
Compare
Choose a tag to compare

v0.4.0

What's Changed

New Contributors

Full Changelog: v0.3.10...v0.4.0

Known Issues

  • Can have some new bugs.
  • Trouble with some Hugen Firmware versions. / The alternative japanese firmware
    for S-A-A-2 isn't supported.

Installation Hint

  • If using binaries on Mac or Linux you have to chmod +x nanovna-saver after
    unzipping as executable flags get lost with zip.
  • For Darwin with library validation a xattr -rd com.apple.quarantine .
    in the unzip directory is necessary.
  • Windows binary for 64Bit systems in NanoVNASaver.x64.zip
  • Windows binary for 32Bit systems in NanoVNASaver.x86.zip

SHA256sums

9c69683dd89620dab39223974afc0f26d025d64e8d63fe0fad596d4f6938a1aa NanoVNASaver.linux.zip
aabcc74eceb2bcf98e3e9422dea138ea5f607ad7ff4ebc03a0202b35fdd99789 NanoVNASaver.macos.zip
7e9fc26385b66e2077e08dfccc4d4a1fa9e549ea9454b2c2ecf3e4ff8daca44c NanoVNASaver.x64.zip
4981daefa39e9c08b30ae1eba1676b793c56093a4a865b001e836f55f30c87d9 NanoVNASaver.x86.zip

New year - new version

04 Jan 08:03
cbcf61a
Compare
Choose a tag to compare

v0.3.10

What's Changed

  • Add 9 and 5 cm bands by @J72IMS in #402
  • Pull/mag loop analysis by @gaionim in #386
  • smaller gui that fits completely on smaller screen, e.g.HD1280x720 by @Ho-Ro in #406
  • More compact layout window layout by @Ho-Ro in #413
  • Format shrinking and better -H detection by @Ho-Ro in #415
  • Added three types of coax from The Wireman to NanoVNASaver/Windows/TD… by @kzembower in #417
  • Apply offset delays after calibration by @jamesl-dm in #419
  • Some minor fixes in plotting by @rjordans in #428
  • Fixing test runner by @rjordans in #431
  • use python3.9 for coverage by @zarath in #432
  • Change calculation of admittance value and unit in marker plotting code by @rjordans in #446
  • Calibration standarts fix and improve by @DiSlord in #450

New Contributors

Full Changelog: v0.3.9...v0.3.10

Known Issues

  • Can have some new bugs.
  • Trouble with some Hugen Firmware versions. / The alternative japanese firmware
    for S-A-A-2 isn't supported.

Installation Hint

  • If using binaries on Mac or Linux you have to chmod +x nanovna-saver after
    unzipping as executable flags get lost with zip.
  • For Darwin with library validation a xattr -rd com.apple.quarantine .
    in the unzip directory is necessary.
  • Windows binary for 64Bit systems in NanoVNASaver.x64.zip
  • Windows binary for 32Bit systems in NanoVNASaver.x86.zip

SHA256sums

e17203c2c78013d6d1f159b6e49a1446b23d5c76ea9e0e95e996817bbcc4c64d NanoVNASaver.linux.zip
3dddf0515bb2ce5ce8509843bd374bf46ca876c82b13af7e25221bc8100085bb NanoVNASaver.macos.zip
757497b2e855c95187d7d6c23d2288bd7613bbc49098b9bd8d9f2fa20fb3a097 NanoVNASaver.x64.zip
d81b30dd0f2ef96ddc9df0f9a83b67d264c68ab15831fdc6dff51ddae323f9e0 NanoVNASaver.x86.zip