fix noise filtering bug in calo digitisation, and restore defaults #113
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
In the calo digitisation classes, when noise filtering is on, the cells which actually get populated with noise becomes smaller and smaller event after event due to the fact that the filtered cells are removed from the cell map (from e.g. this:
k4RecCalorimeter/RecCalorimeter/src/components/NoiseCaloCellsFromFileTool.cpp
Line 110 in af83315
This PR fixes the problem.
Also, a PR recently merged (#107) changed some default values of the properties of CreateCaloCells. Even though those are configurables and can be modified at python level, for backward compatibility I'd rather restore the original values as mentioned here #107 (comment)
@kjvbrt I think @BrieucF is still on vacation so could you please have a look? Since it's a bug fix this is quite urgent. When merged I can then open a follow-up PR to fix the things mentioned in #107 (comment)
Thanks, Giovanni