How do I add R513A calls to your CSharp example? #635

Open
wenminluo opened this issue Dec 20, 2024 · 3 comments
Open

How do I add R513A calls to your CSharp example? #635

wenminluo opened this issue Dec 20, 2024 · 3 comments

Comments

@wenminluo
Copy link

Dear author,
I tried to directly add R513A selection to the Csharp example you provided for invocation test, but the error, the detailed error message is shown in the figure, what is wrong, please take a look:
屏幕截图 2024-12-20 100356-11
屏幕截图 2024-12-20 100549-22

Thanks!

@ianhbell
Copy link
Contributor

That's just a warning. For the more updated parameters, see https://pages.nist.gov/REFPROP-docs/#new-refrigerant-models-2023

@wenminluo
Copy link
Author

That's just a warning. For the more updated parameters, see https://pages.nist.gov/REFPROP-docs/#new-refrigerant-models-2023

Ok,Thank you! If there is a result, does this mean that the warning can be ignored and the calculation can be used directly?

@ianhbell
Copy link
Contributor

You get a result, but it is based on an estimation scheme for interaction parameters, so you need to treat the value with caution.