function magia_input_qc(subject,input,study_specs)
if(isnan(study_specs.dose) || study_specs.dose <= 0)
fprintf('Could not create input QC figure because the dose has not been specified for %s.\n',subject);
return;
end
if(isnan(study_specs.weight) || study_specs.weight <= 0)
fprintf('Could not create input QC figure because the weight has not been specified for %s.\n',subject);
return;
end
if(strcmp(study_specs.tracer,'unknown'))
fprintf('Could not create input QC figure for %s because the tracer has not been specified.\n',subject);
return;
end
switch study_specs.input_type
case {'plasma','blood'}
t = input(:,1);
input = input(:,2);
p = 1;
case {'ref' 'sca_ref'}
t = mean(study_specs.frames,2);
p = 0;
end
% Convert to kBq
if(max(input) > 1000)
input = input*0.001;
end
% Convert to SUV
c = study_specs.dose/study_specs.weight;
suv_input = input/c;
try
fig = magia_calculate_input_boundaries(study_specs.tracer,p);
title('Input function inspection');
hold on; plot(t,suv_input,'k','LineWidth',1.5);
xlim([0 t(end)]);
add_to_qc_pic(subject,fig)
close(fig);
catch
warning('Could not create input qc figure.');
end
end