Please ensure to use BART at least in version
v0.8.00-188-g2619016
The visualization is based on python3. You need to have the packages
numpy, matplotlib, mpl_toolkits, sys, os
installed.
A non-prepared IR bSSFP is no standard sequence in BARTs simulation interface. Please comment out
diff --git a/src/simu/simulation.c b/src/simu/simulation.c
index 6fe627cd4..13397c4d2 100644
--- a/src/simu/simulation.c
+++ b/src/simu/simulation.c
@@ -901,9 +901,9 @@ void bloch_simulation(const struct sim_data* _data, int R, float (*m_state)[R][3
// Alpha/2 and TR/2 signal preparation
- if ( (SEQ_BSSFP == data.seq.seq_type)
- || (SEQ_IRBSSFP == data.seq.seq_type))
- alpha_half_preparation(&data, h, tol, N, P, xp);
+ // if ( (SEQ_BSSFP == data.seq.seq_type)
+ // || (SEQ_IRBSSFP == data.seq.seq_type))
+ // alpha_half_preparation(&data, h, tol, N, P, xp);
float mtr[M][M];
float mte[2][M][M];
All simulations run with ./run.sh
.
To run the simulations AND create figures execute: ./run_figs.sh
.