ergoCub 1.1 S/N:001 β Fingers cannot reach the upper limits and have jerky motions #1703
Comments
Hi @PasMarra, thanks for the feedback. |
Thanks, @PasMarra for the detailed analysis. it's interesting to see also the motor position, the PWM output and the current while performing the movements. |
@maggia80 it is not a problem for us to run the experiments again - but it seems the problem is already known and under investigation from iCub Tech. are you sure you need additional data? |
@lornat75 yes, as @AntonioConsilvio mentioned we know that there are some problems in the fingers and we are working on it. In the experiments above I see different issues and some more data could help iCub Tech and @PasMarra too to have more awareness of the system. |
Hi guys, just an update to say that |
Robot Name π€
ergoCub 1.1 S/N:001
Request/Failure description
While testing the aperture and closure of the fingers, I've noticed the following:
thumb_add
maximum reachable value is90 deg
, but for the documentation is100 deg
.Detailed context
I'll provide some plots, each one shows the desired trajectory vs the joint actual trajectory for both the hands, the joints values are in radian.
Additional context
thumb_add
thumb_add
thumb_oc
thumb_oc
index_add
index_add
index_oc
index_oc
middle_oc
middle_oc
ring_pinky_oc
ring_pinky_oc
How does it affect you?
No response
The text was updated successfully, but these errors were encountered: