Robot Name πŸ€–

ergoCub 1.1 S/N:001

Request/Failure description

While testing the aperture and closure of the fingers, I've noticed the following:

  • Jerky movements when there is a zero position reference.
  • thumb_add maximum reachable value is 90 deg, but for the documentation is 100 deg.
  • several fingers cannot reach maximum value.

Detailed context

I'll provide some plots, each one shows the desired trajectory vs the joint actual trajectory for both the hands, the joints values are in radian.

Additional context

thumb_add

thumb_add

thumb_add_zoom
thumb_add

thumb_oc

thumb_oc
thumb_oc

index_add

index_add
index_add

index_oc

index_oc
index_oc

middle_oc

middle_oc
middle_oc

ring_pinky_oc

ring_pinky_oc
ring_pinky_oc

How does it affect you?

No response

@github-actions github-actions bot changed the title Fingers cannot reach the upper limits and have jerky motions ergoCub 1.1 S/N:001 – Fingers cannot reach the upper limits and have jerky motions Dec 13, 2023
@github-actions github-actions bot added the ergoCub 1.1 S/N:001 ergoCub1.1 platform label Dec 13, 2023
@AntonioConsilvio
Copy link
Contributor

Hi @PasMarra, thanks for the feedback.
We are already aware of the problems present on the fingers and have an internal issue where we are planning how to take corrective action.

@maggia80
Copy link
Contributor

Thanks, @PasMarra for the detailed analysis. it's interesting to see also the motor position, the PWM output and the current while performing the movements.

@lornat75
Copy link
Member

lornat75 commented Dec 14, 2023

@maggia80 it is not a problem for us to run the experiments again - but it seems the problem is already known and under investigation from iCub Tech. are you sure you need additional data?

@maggia80
Copy link
Contributor

@lornat75 yes, as @AntonioConsilvio mentioned we know that there are some problems in the fingers and we are working on it. In the experiments above I see different issues and some more data could help iCub Tech and @PasMarra too to have more awareness of the system.
But of course, those are data we can collect and report here in this issue.

@sgiraz sgiraz moved this from Triage to Backlog in iCub Tech Support Jan 4, 2024
@sgiraz sgiraz moved this from Backlog to In Progress in iCub Tech Support Mar 6, 2024
@sgiraz sgiraz assigned Miche19 and unassigned simeonedussoni Mar 6, 2024
@sgiraz
Copy link
Contributor

sgiraz commented Mar 6, 2024

Hi guys,

just an update to say that team-dev w/ the support of @PasMarra is working on finding a solution to fix this issue.

cc @AntonioConsilvio @Fabrizio69 @fbiggi @fiorisi