Skip to content

Latest commit

 

History

History
93 lines (72 loc) · 4.85 KB

README.md

File metadata and controls

93 lines (72 loc) · 4.85 KB

Hikvision to MQTT

Start-up

  1. Download the project:

     git clone https://github.com/zoilomora/hikvision-to-mqtt.git
     # or
     wget https://github.com/zoilomora/hikvision-to-mqtt/archive/master.zip
    
  2. Check the docker-compose.yml to see if there are any conflicts with the ports.

  3. Start the whole environment:

     make start
    
  4. Once started you will be in a shell inside the php container, check the correct functioning of the system:

     /var/app $ console about
      -------------------- ---------------------------------------- 
       Symfony                                                      
      -------------------- ---------------------------------------- 
       Version              5.0.2                                   
       Long-Term Support    No                                      
       End of maintenance   07/2020                                 
       End of life          07/2020                                 
      -------------------- ---------------------------------------- 
       Kernel                                                       
      -------------------- ---------------------------------------- 
       Type                 ZoiloMora\HikvisionCommunicator\Kernel  
       Environment          dev                                     
       Debug                true                                    
       Charset              UTF-8                                   
       Cache directory      ./var/cache/dev (674 KiB)               
       Log directory        ./var/log (0 B)                         
      -------------------- ---------------------------------------- 
       PHP                                                          
      -------------------- ---------------------------------------- 
       Version              7.4.1                                   
       Architecture         64 bits                                 
       Intl locale          n/a                                     
       Timezone             UTC (2020-01-06T12:39:19+00:00)         
       OPcache              false                                   
       APCu                 false                                   
       Xdebug               false                                   
      -------------------- ---------------------------------------- 
       Environment (.env)                                           
      -------------------- ---------------------------------------- 
       APP_ENV              dev                                     
       APP_SECRET           154543ee90e00d4cb8d63fe74bd73a60        
       TIMEZONE             Europe/Madrid                           
       FAKE_SMTP_API_URI    http://fake-smtp-server:1080            
       MQTT_CLIENT_ID       hikvision                               
       MQTT_BROKER          mqtt                                    
       MQTT_PORT            1883                                    
       MQTT_TOPIC           alerts                                  
      -------------------- ----------------------------------------
    
  5. Now leave the container:

     /var/app $ exit
    
  6. You can leave the system connected:

     docker-compose up -d
    

DVR settings

  1. Use the iVMS-4200 Client to access the remote configuration of the device.

  2. Go to Event > Email and configure the fake-smpt-server as SMTP Server (default port 1025). You can enter any source and destination address, for example:

     Sender Address: <hikvision> [email protected]
     Receiver Address: <server> [email protected]
    
  3. Activate in the events that the Linkage Action: Email Linkage.

Check operation

Run a MQTT Client to monitor the topic (replace <server_id> with the IP Address of your MQTT Server):

docker run --init -it --rm efrecon/mqtt-client sub -h <server_ip> -t "alerts" -v

# Result
alerts {"type":"Motion Detected","device":{"name":"Embedded Net DVR","serial_number":"******"},"camera":{"name":"Camera 1","number":"A1"},"occurred_on":{"date":"2020-01-06 14:51:02.000000","timezone_type":3,"timezone":"Europe\/Madrid"}}

You can also see the logs of the docker containers to see what is happening:

docker-compose logs -f

# Result
mqtt_1 | 1578318663: New connection from 10.10.12.4 on port 1883.
mqtt_1 | 1578318663: New client connected from 10.10.12.4 as hikvision (p2, c1, k60).
php_1  | Published message: {"type":"Motion Detected","device":{"name":"Embedded Net DVR","serial_number":"******"},"camera":{"name":"Camera 1","number":"A1"},"occurred_on":{"date":"2020-01-06 14:51:02.000000","timezone_type":3,"timezone":"Europe\/Madrid"}}
mqtt_1 | 1578318663: Client hikvision disconnected.