Device 9a:02:57:1e:8f:01, *** Make *** *** Model ***

Test Roles

Role Name Status
Operator *** Operator Name ***
Approver *** Approver Name ***

Test Iteration

Test parameter Value
Test report start date XXX
Test report end date XXX

| | Attempt number | 1 |

Device Identification

Device Entry
Name *** Name ***
GUID *** GUID ***
MAC addr 9a:02:57:1e:8f:01
Hostname *** Network Hostname ***
Type *** Type ***
Make *** Make ***
Model *** Model ***
Serial Number *** Serial ***
Firmware Version *** Firmware Version ***

Device Description

![Image of device](*** Device Image URL ***)

*** Device Description ***

Device documentation

[Device datasheets](*** Device Datasheets URL ) [Device manuals]( Device Manuals URL ***)

Report summary

Overall device result FAIL

Some tests report as GONE. Please check for possible misconfiguration

Category Total Tests Result Required Pass Required Pass for PoE Devices Required Pass for BACnet Devices Required Pass for IoT Devices Recommended Pass Other
Base 2 FAIL 1/0/1 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0
Connection 12 FAIL 3/5/4 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0
Security 13 FAIL 2/1/7 0/0/0 0/0/1 0/0/0 0/0/2 0/0/0
NTP 2 PASS 2/0/0 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0
DNS 1 SKIP 0/0/1 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0
Communication 2 PASS 2/0/0 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0
Protocol 2 FAIL 0/0/0 0/0/0 0/1/1 0/0/0 0/0/0 0/0/0
PoE 1 SKIP 0/0/0 0/0/1 0/0/0 0/0/0 0/0/0 0/0/0
IoT 1 SKIP 0/0/0 0/0/0 0/0/0 0/0/1 0/0/0 0/0/0
Other 2 GONE 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0 0/2/0
Syntax: Pass / Fail / Skip
Expectation pass fail skip gone
Required Pass 10 1 13 5
Required Pass for PoE Devices 0 0 1 0
Required Pass for BACnet Devices 0 1 2 0
Required Pass for IoT Devices 0 0 1 0
Recommended Pass 0 0 2 0
Other 1 0 4 2
Result Test Category Expectation Notes
pass base.startup.dhcp Base Required Pass
skip base.switch.ping Base Required Pass No local IP has been set, check system config
skip cloud.udmi.event_pointset IoT Required Pass for IoT Devices No device id
skip cloud.udmi.event_system Other Other No device id
skip cloud.udmi.provision Other Other No device id
skip cloud.udmi.state_pointset Other Other No device id
skip cloud.udmi.state_system Other Other No device id
pass communication.network.min_send Communication Required Pass ARP packets received. Data packets were sent at a frequency of less than 5 minutes
pass communication.network.type Communication Required Pass Broadcast packets received. Unicast packets received.
pass connection.base.target_ping Connection Required Pass target reached
gone connection.ipaddr.dhcp_disconnect Connection Required Pass
gone connection.ipaddr.disconnect_ip_change Connection Required Pass
gone connection.ipaddr.ip_change Connection Required Pass
gone connection.ipaddr.private_address Connection Required Pass
pass connection.manual.comms_down Connection Required Pass Manual test - Device passed this manual test
skip connection.manual.sec_eth_port Connection Required Pass Manual test - Test results not inputted into module_config
pass connection.network.mac_address Connection Required Pass Device MAC address is 9a:02:57:1e:8f:01
fail connection.network.mac_oui Connection Required Pass Manufacturer prefix not found!
skip connection.switch.port_duplex Connection Required Pass No local IP has been set, check system config
skip connection.switch.port_link Connection Required Pass No local IP has been set, check system config
skip connection.switch.port_speed Connection Required Pass No local IP has been set, check system config
skip dns.network.hostname_resolution DNS Required Pass Device did not send any DNS requests
pass dot1x.dot1x Other Other Authentication for 9a:02:57:1e:8f:01 succeeded.
pass ntp.network.ntp_support NTP Required Pass Using NTPv4.
pass ntp.network.ntp_update NTP Required Pass Device clock synchronized.
skip poe.switch.power PoE Required Pass for PoE Devices No local IP has been set, check system config
fail protocol.bacext.pic Protocol Required Pass for BACnet Devices PICS file defined however a BACnet device was not found.
skip protocol.bacext.version Protocol Required Pass for BACnet Devices Bacnet device not found.
skip security.discover.firmware Security Required Pass for BACnet Devices Could not retrieve a firmware version with nmap. Check bacnet port.
pass security.nmap.http Security Required Pass No running http servers have been found.
pass security.nmap.ports Security Required Pass Only allowed ports found open.
skip security.password.http Security Required Pass Port 80 not open on target device.
skip security.password.https Security Required Pass Port 443 not open on target device.
skip security.password.ssh Security Required Pass Port 22 not open on target device.
skip security.password.telnet Security Required Pass Port 23 not open on target device.
gone security.ssh.version Security Required Pass
skip security.tls.v1_2_client Security Required Pass No client initiated TLS communication detected
skip security.tls.v1_2_server Security Required Pass IOException unable to connect to server.
skip security.tls.v1_3_client Security Recommended Pass No client initiated TLS communication detected
skip security.tls.v1_3_server Security Recommended Pass IOException unable to connect to server.
skip security.tls.v1_server Security Required Pass IOException unable to connect to server.
gone unknown.fake.llama Other Other
gone unknown.fake.monkey Other Other

Module pass

Module Config

Attribute Value
enabled True

Module fail

Module Config

Attribute Value
enabled True

Module ping

Report

--------------------
Baseline ping test report

LOCAL_IP not configured, assuming no network switch

Done with basic connectivity tests

--------------------
base.startup.dhcp
--------------------
Check the base DHCP startup exchange
--------------------
See log above
--------------------
RESULT pass base.startup.dhcp

--------------------
base.switch.ping
--------------------
Attempt to ping access switch (if configured)
--------------------
See log above
--------------------
RESULT skip base.switch.ping No local IP has been set, check system config

--------------------
connection.base.target_ping
--------------------
Attempt to ping the Device Under Test
--------------------
See log above
--------------------
RESULT pass connection.base.target_ping target reached

Module Config

Attribute Value
enabled True

Module nmap

Report

--------------------
security.nmap.ports
--------------------
Automatic TCP/UDP port scan using nmap
--------------------
# Nmap XXX scan initiated XXX as: nmap -v -n -T5 -sT -sU --host-timeout=4m --open -pU:47808,T:23,443,80, -oG XXX/tmp/nmap.log X.X.X.X
# Ports scanned: TCP(3;23,80,443) UDP(1;47808) SCTP(0;) PROTOCOLS(0;)
Host: X.X.X.X () Status: Up
Host: X.X.X.X () Ports: 47808/closed/udp//bacnet///
# Nmap done at XXX -- 1 IP address (1 host up) scanned in XXX
No invalid ports found.
--------------------
RESULT pass security.nmap.ports Only allowed ports found open.

--------------------
security.nmap.http
--------------------
Check that the device does not have open ports exposing an unencrypted web interface using HTTP
--------------------
# Nmap XXX scan initiated XXX as: nmap -v -n -T5 -A --script http-methods --host-timeout=4m --open -p- -oG XXX/tmp/http.log X.X.X.X
# Ports scanned: TCP(65535;1-65535) UDP(0;) SCTP(0;) PROTOCOLS(0;)
Host: X.X.X.X () Status: Up
Host: X.X.X.X () Ports: 10000/open/tcp//snet-sensor-mgmt?///
# Nmap done at XXX -- 1 IP address (1 host up) scanned in XXX
No running http servers have been found.
--------------------
RESULT pass security.nmap.http No running http servers have been found.

Module Config

Attribute Value
timeout_sec 600
enabled True

Module discover

Report

--------------------
security.discover.firmware
--------------------
Automatic bacnet firmware scan using nmap
--------------------
PORT      STATE  SERVICE
47808/udp closed bacnet
MAC Address: 9A:02:57:1E:8F:01 (Unknown)
--------------------
RESULT skip security.discover.firmware Could not retrieve a firmware version with nmap. Check bacnet port.

Module Config

Attribute Value
enabled True

Module switch

Report

--------------------
connection.switch.port_link
--------------------
Connect the device to the network switch. Check the device and the switch for the green connection light & no errors
--------------------
LOCAL_IP not configured, assuming no network switch.
--------------------
RESULT skip connection.switch.port_link No local IP has been set, check system config

--------------------
connection.switch.port_speed
--------------------
Verify the device auto-negotiates connection speed
--------------------
LOCAL_IP not configured, assuming no network switch.
--------------------
RESULT skip connection.switch.port_speed No local IP has been set, check system config

--------------------
connection.switch.port_duplex
--------------------
Verify the device supports full duplex
--------------------
LOCAL_IP not configured, assuming no network switch.
--------------------
RESULT skip connection.switch.port_duplex No local IP has been set, check system config

--------------------
poe.switch.power
--------------------
Verify that the device draws less than the maximum power allocated by the port. This is 15.4W for 802.3af and 30W for 802.3at
--------------------
LOCAL_IP not configured, assuming no network switch.
--------------------
RESULT skip poe.switch.power No local IP has been set, check system config

Module Config

Attribute Value
enabled True
timeout_sec 0
poe {'enabled': True}

Module bacext

Report

--------------------
protocol.bacext.version
--------------------
Verify and record version of Bacnet used by the device
--------------------
 Bacnet device not found.
--------------------
RESULT skip protocol.bacext.version Bacnet device not found.

--------------------
protocol.bacext.pic
--------------------
Verify BACnet traffic is compliant to the PIC statement
--------------------
PICS file defined however a BACnet device was not found.
--------------------
RESULT fail protocol.bacext.pic PICS file defined however a BACnet device was not found.

Module Config

Attribute Value
enabled True

Module tls

Report

--------------------
Collecting TLS cert from target address

Gathering TLS 1 Server Information....
TLS 1Server Implementation Skipping Test, could not open connection
TLS 1 Server Information Complete.


Gathering TLS 1.2 Server Information....
TLS 1.2Server Implementation Skipping Test, could not open connection
TLS 1.2 Server Information Complete.


Gathering TLS 1.3 Server Information....
TLS 1.3Server Implementation Skipping Test, could not open connection
TLS 1.3 Server Information Complete.


Gathering TLS Client X.X.X.X Information....
TLS Client Information Complete.
Gathering TLS Client X.X.X.X Information....
TLS Client Information Complete.

--------------------
security.tls.v1_2_client
--------------------
Verify the device supports at least TLS 1.2 (as a client)
--------------------
See log above
--------------------
RESULT skip security.tls.v1_2_client No client initiated TLS communication detected

--------------------
security.tls.v1_2_server
--------------------
Verify the device supports TLS 1.2 (as a server)
--------------------
See log above
--------------------
RESULT skip security.tls.v1_2_server IOException unable to connect to server.

--------------------
security.tls.v1_3_client
--------------------
Verify the device supports at least TLS 1.3 (as a client)
--------------------
See log above
--------------------
RESULT skip security.tls.v1_3_client No client initiated TLS communication detected

--------------------
security.tls.v1_3_server
--------------------
Verify the device supports TLS 1.3 (as a server)
--------------------
See log above
--------------------
RESULT skip security.tls.v1_3_server IOException unable to connect to server.

--------------------
security.tls.v1_server
--------------------
Verify the device supports at least TLS 1.0 (as a server)
--------------------
See log above
--------------------
RESULT skip security.tls.v1_server IOException unable to connect to server.

Module Config

Attribute Value
enabled True
timeout_sec 0
ca_file CA_Faux.pem

Module password

Report

--------------------
security.admin.password.http
--------------------
Verify all device manufacturer default passwords are changed for protocol: http, and new passwords are set.
--------------------

Starting Nmap 7.60 ( https://nmap.org ) at XXX
Nmap scan report for daq-faux-1 (X.X.X.X)
Host is up (XXX).

PORT   STATE  SERVICE
80/tcp closed http
MAC Address: 9A:02:57:1E:8F:01 (Unknown)

Nmap done: 1 IP address (1 host up) scanned in XXX
Could not connect to specified port on host.
--------------------
RESULT skip security.password.http Port 80 not open on target device.

--------------------
security.admin.password.https
--------------------
Verify all device manufacturer default passwords are changed for protocol: https, and new passwords are set.
--------------------

Starting Nmap 7.60 ( https://nmap.org ) at XXX
Nmap scan report for daq-faux-1 (X.X.X.X)
Host is up (XXX).

PORT    STATE  SERVICE
443/tcp closed https
MAC Address: 9A:02:57:1E:8F:01 (Unknown)

Nmap done: 1 IP address (1 host up) scanned in XXX
Could not connect to specified port on host.
--------------------
RESULT skip security.password.https Port 443 not open on target device.

--------------------
security.admin.password.ssh
--------------------
Verify all device manufacturer default passwords are changed for protocol: ssh, and new passwords are set.
--------------------

Starting Nmap 7.60 ( https://nmap.org ) at XXX
Nmap scan report for daq-faux-1 (X.X.X.X)
Host is up (XXX).

PORT   STATE  SERVICE
22/tcp closed ssh
MAC Address: 9A:02:57:1E:8F:01 (Unknown)

Nmap done: 1 IP address (1 host up) scanned in XXX
Could not connect to specified port on host.
--------------------
RESULT skip security.password.ssh Port 22 not open on target device.

--------------------
security.admin.password.telnet
--------------------
Verify all device manufacturer default passwords are changed for protocol: telnet, and new passwords are set.
--------------------

Starting Nmap 7.60 ( https://nmap.org ) at XXX
Nmap scan report for daq-faux-1 (X.X.X.X)
Host is up (XXX).

PORT   STATE  SERVICE
23/tcp closed telnet
MAC Address: 9A:02:57:1E:8F:01 (Unknown)

Nmap done: 1 IP address (1 host up) scanned in XXX
Could not connect to specified port on host.
--------------------
RESULT skip security.password.telnet Port 23 not open on target device.

Module Config

Attribute Value
enabled True
timeout_sec 0
dictionary_dir resources/faux

Module udmi

Report

--------------------
cloud.udmi.provision
--------------------
Validates device provision payload.
--------------------
No device id
--------------------
RESULT skip cloud.udmi.provision No device id

--------------------
cloud.udmi.state_system
--------------------
Validates device state_system payload.
--------------------
No device id
--------------------
RESULT skip cloud.udmi.state_system No device id

--------------------
cloud.udmi.state_pointset
--------------------
Validates device state_pointset payload.
--------------------
No device id
--------------------
RESULT skip cloud.udmi.state_pointset No device id

--------------------
cloud.udmi.event_system
--------------------
Validates device event_system payload.
--------------------
No device id
--------------------
RESULT skip cloud.udmi.event_system No device id

--------------------
cloud.udmi.event_pointset
--------------------
Validates device event_pointset payload.
--------------------
No device id
--------------------
RESULT skip cloud.udmi.event_pointset No device id

Module Config

Attribute Value
enabled True

Module manual

Report

--------------------
connection.manual.comms_down
--------------------

--------------------
No additional information provided
--------------------
RESULT pass connection.manual.comms_down Manual test - Device passed this manual test

--------------------
connection.manual.sec_eth_port
--------------------

--------------------
No additional information provided
--------------------
RESULT skip connection.manual.sec_eth_port Manual test - Test results not inputted into module_config

Module Config

Attribute Value
enabled True

Module network

Report

--------------------
communication.network.min_send
--------------------
Device sends data at a frequency of less than 5 minutes.
--------------------











RESULT pass communication.network.min_send ARP packets received. Data packets were sent at a frequency of less than 5 minutes
--------------------
communication.network.type
--------------------
Device sends unicast or broadcast packets.
--------------------


RESULT pass communication.network.type Broadcast packets received. Unicast packets received.
--------------------
ntp.network.ntp_support
--------------------
Device supports NTP version 4.
--------------------
RESULT pass ntp.network.ntp_support Using NTPv4.
--------------------
ntp.network.ntp_update
--------------------
Device synchronizes its time to the NTP server.
--------------------
RESULT pass ntp.network.ntp_update Device clock synchronized.
--------------------
connection.network.mac_oui
--------------------
Check Physical device address OUI against IEEE registration and verify it is registered with the correct manufacturer
--------------------
Using the host hardware address 9a:02:57:1e:8f:01
Mac OUI Test
--------------------
RESULT fail connection.network.mac_oui Manufacturer prefix not found!

--------------------
connection.network.mac_address
--------------------
Reports device MAC address
--------------------
Device MAC address is 9a:02:57:1e:8f:01
--------------------
RESULT pass connection.network.mac_address Device MAC address is 9a:02:57:1e:8f:01

--------------------
dns.network.hostname_resolution
--------------------
Check device uses the DNS server from DHCP and resolves hostnames
--------------------
RESULT skip dns.network.hostname_resolution Device did not send any DNS requests

Module Config

Attribute Value
enabled True

Module dot1x

Report

--------------------
dot1x.dot1x
--------------------
Dot1x authentication tests
--------------------
n/a
--------------------
RESULT pass dot1x.dot1x Authentication for 9a:02:57:1e:8f:01 succeeded.

Module Config

Attribute Value
enabled True

Report complete