influxdb:
host: 127.0.0.1
port: 8086
# this obviously has to match your setup, these are just placeholders
database: homeassistant
username: homeassistant
password: homeassistant
max_retries: 3
default_measurement: units
# this is recommended to save space, there is no point to save solar data with nanosecond precision
precision: ms
tags:
source: HA
# for easier navigation, I would not use this for selection in the dashboard, use entity_id
tags_attributes:
- friendly_name
include:
# this will include the sun data for the dashboard, alternatively leave this out and
# use Grafanas Sun&Moon plugin
domains:
- sun
entity_globs:
- "*.hm800_*"
entities:
- weather.home
- sensor.hichi_gth_sml_total_in
- sensor.hichi_gth_sml_total_out
- sensor.hichi_gth_sml_power_curr
# if you use tasmota for reading out your smart meter you will have to attach the correct
# attributes to the MQTT entities, otherwise it will not be recognized by HomeAssitants
# energy dashboard and it will not land in the correct unit bucket within InfluxDB
homeassistant:
customize:
sensor.hichi_gth_sml_volt_p1:
device_class: voltage
unit_of_measurement: V
state_class: measurement
sensor.hichi_gth_sml_volt_p2:
device_class: voltage
unit_of_measurement: V
state_class: measurement
sensor.hichi_gth_sml_volt_p3:
device_class: voltage
unit_of_measurement: V
state_class: measurement
sensor.hichi_gth_sml_amperage_p1:
device_class: current
unit_of_measurement: A
state_class: measurement
sensor.hichi_gth_sml_amperage_p2:
device_class: current
unit_of_measurement: A
state_class: measurement
sensor.hichi_gth_sml_amperage_p3:
device_class: current
unit_of_measurement: A
state_class: measurement
sensor.hichi_gth_sml_phase_angle_p1:
device_class: phase_angle
unit_of_measurement: °
state_class: measurement
sensor.hichi_gth_sml_phase_angle_p2:
device_class: phase_angle
unit_of_measurement: °
state_class: measurement
sensor.hichi_gth_sml_phase_angle_p3:
device_class: phase_angle
unit_of_measurement: °
state_class: measurement
sensor.hichi_gth_sml_frequency:
device_class: frequency
unit_of_measurement: Hz
state_class: measurement
sensor.hichi_gth_sml_total_in:
device_class: energy
unit_of_measurement: kWh
state_class: total
sensor.hichi_gth_sml_total_out:
device_class: energy
unit_of_measurement: kWh
state_class: total
sensor.hichi_gth_sml_power_curr:
device_class: power
unit_of_measurement: "W"
state_class: measurement