-
Notifications
You must be signed in to change notification settings - Fork 24
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Create piezometric_database_ver2.yaml
- Loading branch information
1 parent
c7ee3e9
commit 65f7a28
Showing
1 changed file
with
205 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,205 @@ | ||
# =================================================================== # | ||
# Save this file in the same directory as GrainSizeTools # | ||
# =================================================================== # | ||
|
||
--- | ||
database_version: 2024.05.21 | ||
|
||
metadata: | ||
author: Marco A. Lopez-Sanchez | ||
contact_email: marcoalopez (at) outlook.com | ||
description: Piezometric database from GrainSizeTools script | ||
created_at: 2024-05-21 | ||
license: Open Database License (ODbL) - version 1.0 | ||
usage_terms: https://opendatacommons.org/licenses/odbl/summary/ | ||
contributors: | ||
|
||
data: | ||
## quartz piezometers ###################################################################### | ||
quartz: | ||
Stipp_Tullis: | ||
year: 2003 | ||
reference: https://doi.org/10.1029/2003GL018444 | ||
B: 669.0 | ||
m: 0.79 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to recrystallization regimes 2 and 3 (SGR, GBM) | ||
|
||
Stipp_Tullis_BLG: | ||
year: 2003 | ||
reference: https://doi.org/10.1029/2003GL018444 | ||
B: 1264.1 | ||
m: 1.64 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to recrystallization regime 1 (BLG) | ||
|
||
Holyoke: | ||
year: 2010 | ||
reference: https://doi.org/10.1016/j.tecto.2010.08.001 | ||
B: 490.3 | ||
m: 0.79 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to recrystallization regimes 2 and 3 (SGR, GBM) | ||
|
||
Holyoke_BLG: | ||
year: 2010 | ||
reference: https://doi.org/10.1016/j.tecto.2010.08.001 | ||
B: 883.9 | ||
m: 1.85 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to recrystallization regimes 2 and 3 (SGR, GBM) | ||
|
||
Cross: | ||
year: 2017 | ||
reference: https://doi.org/10.1002/2017GL073836 | ||
B: 593.0 | ||
m: 0.71 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: None | ||
|
||
Cross_HR: | ||
year: 2017 | ||
reference: https://doi.org/10.1002/2017GL073836 | ||
B: 450.9 | ||
m: 0.63 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS). | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: None | ||
|
||
Shimizu: | ||
year: 2008 | ||
reference: https://doi.org/10.1016/j.jsg.2008.03.004 | ||
B: 352.0 | ||
m: 0.8 | ||
warn: Please ensure that you have entered the apparent grain size as the median in log (base e) scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: | | ||
The Shimizu (2008) piezometer requires entering the grain size as the | ||
logarithm of the median apparent grain size calculated using equivalent | ||
circular diameters with no stereological correction. It uses a different | ||
piezometer model to the Twiss model in which the stress estimation is | ||
temperature-dependent. | ||
Twiss: | ||
year: 1977 | ||
reference: https://www.doi.org/10.1007/BF01637105 | ||
B: 550.0 | ||
m: 0.68 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean grain size. | ||
linear_intercepts: false | ||
correction_factor: 1.5 | ||
notes: | | ||
Twiss (1977) piezometer was calibrated using the linear intercepts (LI) multiplied | ||
by 1.5 (correction factor). Equivalent circular diameters (ECD) without stereological | ||
correction must be converted to LIs using the empirical equation of De Hoff and | ||
Rhines (1968) as follows LI = (1.5 / sqrt(4/pi)) * ECD | ||
## olivine piezometers ###################################################################### | ||
olivine: | ||
VanderWal_wet: | ||
year: 1993 | ||
reference: https://doi.org/10.1029/93GL01382 | ||
B: 1355.4 | ||
m: 0.75 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean in linear scale. | ||
linear_intercepts: true | ||
correction_factor: 1.5 | ||
notes: | | ||
The Van der Wal (1993) piezometer was calibrated using the linear intercept (LI) grain size | ||
multiplied by 1.5 (correction factor). ECDs without stereological correction will be converted | ||
to LIs using the empirical equation of De Hoff and Rhines (1968) LI = (1.5 / sqrt(4/pi)) * ECD | ||
Jung_Karato: | ||
year: 2001 | ||
reference: https://doi.org/10.1016/S0191-8141(01)00005-0 | ||
B: 5461.03 | ||
m: 0.85 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean in linear scale. | ||
linear_intercepts: true | ||
correction_factor: 1.5 | ||
notes: | | ||
The Jung & Karato (2001) piezometer was calibrated using the linear intercept (LI) grain size | ||
multiplied by 1.5 (correction factor). ECDs without stereological correction will be converted | ||
to LIs using the empirical equation of De Hoff and Rhines (1968) LI = (1.5 / sqrt(4/pi)) * ECD | ||
## calcite piezometers ###################################################################### | ||
calcite: | ||
Rutter_SGR: | ||
year: 1995 | ||
reference: https://doi.org/10.1029/95JB02500 | ||
B: 812.83 | ||
m: 0.88 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean in linear scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to subgrain rotation recrystallization | ||
|
||
Rutter_GBM: | ||
year: 1995 | ||
reference: https://doi.org/10.1029/95JB02500 | ||
B: 2691.53 | ||
m: 0.89 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean in linear scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: Only applies to grain boundary migration recrystallization | ||
|
||
Barnhoorn: | ||
year: 2003 | ||
reference: https://doi.org/10.1016/j.jsg.2003.11.024 | ||
B: 537.03 | ||
m: 0.82 | ||
warn: Please ensure that you have entered the apparent grain size as the arithmetic mean in linear scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: None | ||
|
||
Platt_Bresser: | ||
year: 2017 | ||
reference: https://doi.org/10.1016/j.jsg.2017.10.012 | ||
B: 538.40 | ||
m: 0.82 | ||
warn: Please ensure that you have entered the apparent grain size as the root mean square (RMS) in linear scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: | | ||
Contrary to other calcite piezometers, this one was calibrated using the RMS mean | ||
instead of the arithmetic mean. | ||
Valcke: | ||
year: 2015 | ||
reference: https://doi.org/10.1144/SP409.4 | ||
B: 1467.92 | ||
m: 1.67 | ||
warn: Please ensure that you have entered the apparent grain size the arithmetic mean in linear scale. | ||
linear_intercepts: false | ||
correction_factor: false | ||
notes: None | ||
|
||
## feldspar piezometers ##################################################################### | ||
feldspar: # feldspar piezometers | ||
Post_Tullis_BLG: | ||
year: 1999 | ||
reference: https://doi.org/10.1016/S0040-1951(98)00260-1 | ||
B: 433.4 | ||
m: 1.52 | ||
warn: Please ensure that you have entered the apparent grain size as the median in linear scale. | ||
linear_intercepts: true | ||
correction_factor: false | ||
notes: | | ||
The Post and Tullis (1999) piezometer was calibrated using the median of the | ||
equivalent circular diameters (ECD) grain size with no stereological correction. | ||
## End of file ############################################################################## |