Parametric EQs

In case of using parametric equalizer, apply preamp of -5.3dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -5.3 dB.

Type Fc Q Gain
Peaking 22 Hz 0.6 -3.8 dB
Peaking 60 Hz 1.52 -1.5 dB
Peaking 187 Hz 1.46 -3.9 dB
Peaking 3092 Hz 2.76 2.6 dB
Peaking 20198 Hz 0.16 5.1 dB
Peaking 654 Hz 1.64 1.5 dB
Peaking 1518 Hz 3.36 -2.5 dB
Peaking 4083 Hz 0.22 0.5 dB
Peaking 5022 Hz 3.69 -2.0 dB
Peaking 6285 Hz 3.53 2.5 dB

Fixed Band EQs

In case of using fixed band (also called graphic) equalizer, apply preamp of -6.3dB (if available) and set gains manually with these parameters.

Type Fc Q Gain
Peaking 31 Hz 1.41 -4.1 dB
Peaking 62 Hz 1.41 -1.6 dB
Peaking 125 Hz 1.41 -1.8 dB
Peaking 250 Hz 1.41 -3.4 dB
Peaking 500 Hz 1.41 2.0 dB
Peaking 1000 Hz 1.41 0.0 dB
Peaking 2000 Hz 1.41 -0.2 dB
Peaking 4000 Hz 1.41 1.5 dB
Peaking 8000 Hz 1.41 2.0 dB
Peaking 16000 Hz 1.41 6.0 dB

Graphs