forked from denniseptian/ZTE-C300
-
Notifications
You must be signed in to change notification settings - Fork 0
/
00. Perintah Dasar OLT
572 lines (512 loc) · 19.3 KB
/
00. Perintah Dasar OLT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
1. Cek Detail Config di Interface ke arah ONT
OLT-ZTE_C320#show run interface gpon-onu_1/2/5:4
Building configuration...
!
interface gpon-onu_1/2/5:4
name Customer-1
description Internet-Customer-1
tcont 1 name acsata profile UP-50M
gemport 1 name Internet unicast tcont 1 dir both
gemport 1 traffic-limit upstream DOWN-50M downstream DOWN-50M
switchport mode hybrid vport 1
service-port 1 vport 1 user-vlan 1247 vlan 1247 svlan 1402
!
end
OLT-ZTE_C320#show run interface gpon-onu_1/2/5:5
Building configuration...
!
interface gpon-onu_1/2/5:5
name Customer-2
description Internet-Customer-2
tcont 1 name acsata profile UP-60M
tcont 1 gap mode2
gemport 1 name Internet unicast tcont 1 dir both
gemport 1 traffic-limit upstream DOWN-60M downstream DOWN-60M
switchport mode hybrid vport 1
service-port 1 vport 1 user-vlan 1245 vlan 1245 svlan 1402
!
end
2. Cek Status Interface ONT
OLT-ZTE_C320#show gpon onu state gpon-olt_1/2/5 4
OnuIndex Admin State OMCC State O7 State Phase State
----------------------------------------------------------------------------
gpon-onu_1/2/5:4 enable disable unknown LOS <----- Tanda Link Down
ONU Number: 0/1
OLT_ZTE_C320#show gpon onu state gpon-olt_1/2/5 5
OnuIndex Admin State OMCC State O7 State Phase State
----------------------------------------------------------------------------
gpon-onu_1/2/5:5 enable enable operation working <----- Tanda Link UP
ONU Number: 1/1
3. Cek Nilai Optik ONT
OLT-ZTE_C320#show pon power attenuation gpon-onu_1/2/5:4
OLT ONU Attenuation
--------------------------------------------------------------------------
up Rx :no signal Tx:N/A N/A
down Tx :4.200(dbm) Rx:N/A N/A
OLT-ZTE_C320#show pon power attenuation gpon-onu_1/2/5:5
OLT ONU Attenuation
--------------------------------------------------------------------------
up Rx :-20.850(dbm) Tx:2.868(dbm) 23.718(dB)
down Tx :4.230(dbm) Rx:-18.210(dbm) 22.440(dB)
4. Cek Utilisasi Bandwith Link ONT Real Time
OLT-ZTE_C320#show interface gpon-onu_1/2/5:4
ONU statistic:
Input rate : 1471 Bps 12 pps
Output rate: 2212 Bps 13 pps
Input bandwidth throughput :0.0%
Output bandwidth throughput: N/A
OLT-ZTE_C320#show interface gpon-onu_1/2/5:5
ONU statistic:
Input rate : 1411 Bps 9 pps
Output rate: 1423 Bps 9 pps
Input bandwidth throughput :0.0%
Output bandwidth throughput: N/A
5. Cek ONT Uptime dan History:
OLT-ZTE_C320#show gpon onu detail-info gpon-onu_1/2/5:5
ONU interface: gpon-onu_1/2/5:5
Name: Customer-2
Type: ZTEG-F660
State: ready
Admin state: enable
Phase state: working
Authentication mode: sn
SN Bind: enable with SN check
Serial number: ZTEGC1192DD7
Password:
Device ID:
Description: Internet-Customer-2
Vport mode: gemport
DBA Mode: Hybrid
ONU Status: enable
OMCI BW Profile: enable
Line Profile: N/A
Service Profile: N/A
Alarm Profile: N/A
Performance Profile: N/A
ONU Distance: 3540m
Online Duration: 10h 42m 07s
FEC: none
------------------------------------------
Authpass Time OfflineTime Cause
1 2018-07-28 04:49:02 2018-07-28 04:49:02 LOS
2 2018-07-28 05:08:31 2018-07-28 05:08:32 LOS
3 2018-07-28 05:13:42 2018-07-28 05:13:42 LOS
4 2018-07-28 05:51:33 2018-07-28 05:51:33 LOS
5 2018-07-28 07:23:11 2018-07-28 07:23:12 LOS
6 2018-07-28 08:14:14 2018-07-28 08:14:14 LOS
7 2018-07-29 11:28:39 2018-07-29 11:30:22 LOS
8 2018-07-29 11:33:33 2018-07-29 11:34:36 LOS
9 2018-07-29 11:36:01 2018-07-29 11:54:32 LOSi
10 2018-07-29 11:56:31 0000-00-00 00:00:00
6. Cek Mac Address Perangkat yang terkoneksi ke ONT
OLT-ZTE_C320#show mac gpon onu gpon-onu_1/2/5:5
Total mac address : 2
Mac address Vlan Type Port Vc
------------------------------------------------------------------------
6c3b.6b51.cc09 1402 Dynamic gpon-onu_1/2/5:5 vport 1
6c3b.6b61.d257 1402 Dynamic gpon-onu_1/2/5:5 vport 1
7. Cek ONT Version
OLT-ZTE_C320#show gpon remote-onu equip gpon-onu_1/2/5:5
Vendor ID: ZTEG
Version: V5.0
SN: ZTEGc1192dd7
Admin status: unlock
Battery backup: false
Security Mode: aes
Product code: 0
TotalPrioQueueNum: 56
TotalTrafficSchNum: 7
TrafficMgmtOption: priority-controlled
OperState: enable
EquipID: F620V5.0
OMCC Version: a0
Security Capability: aes
Model: F620V5.0
Survival time: N/A
TotalGemPortNum: 256
SysUpTime: 0
8. Cek Status Port di ONT
OLT-ZTE_C320#show gpon remote-onu interface eth gpon-onu_1/2/5:5
Interface: eth_0/1
Speed status: full-100
Operate status:enable
Admin status: unlock
Arc: 0
Arc-interval 0
Expect-type: 0
Speed config: auto
Eth-loop: disable
Max-frame: 1632
Pause-time: 0
Wiring : dce
BridgeOrIP: either
PPPOE-filter: disable
Power-control: disable
9. Reboot/Restart ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/2/5:5
OLT-ZTE_C320(gpon-onu-mng)#reboot
10. Shutdown Port 1 di ONT
OLT-ZTE_C320#config t
Enter configuration commands, one per line. End with CTRL/Z.
OLT-ZTE_C320(config)#pon-onu
OLT-ZTE_C320(config)#pon-onu-mng gpon-onu_1/2/5:5
OLT-ZTE_C320(gpon-onu-mng)#interface eth eth_0/1 state lock
11. Cek Konfigurasi PON ONU
JKT-OLT-RO#show onu running config gpon-onu_1/2/11:8
pon-onu-mng gpon-onu_1/2/11:8
service Internet-Customer1 gemport 1 vlan 671
service OAM gemport 2 vlan 1450
service Internet-Customer2 gemport 3 vlan 1490
vlan port eth_0/1 mode tag vlan 671
vlan port eth_0/3 mode tag vlan 1490
CHECKING OLT UPTIME
OL01#show system-group
System Description: ZX Version V4.
Started before: 47484 days, 5 hours, 25 minutes
OL01#
CHECKING OLT BOARD
GTGOE = 8 Port (O = Octal)
GTGH = 16 Port (H = Hexa)
OL01#sho card
Rack Shelf Slot CfgType RealType Port HardVer SoftVer Status
——————————————————————————-
1 1 0 PRWG PRWG N/A INSERVICE
1 1 1 PRWG PRWG N/A INSERVICE
1 1 2 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 3 GTGH GTGHG 16 120700 V1. INSERVICE
1 1 4 GTGO GTGOE 8 110301 V1.2 INSERVICE
1 1 5 GTGO GTGOE 8 110301 V1.2 INSERVICE
1 1 6 GTGO GTGOE 8 110301 V1 INSERVICE
1 1 7 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 8 GTGO GTGOE 8 110301 V1 INSERVICE
1 1 9 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 10 SCXN SCXN N/A 120902 V1. STANDBY –> Control Module
1 1 11 SCXN SCXN N/A 120902 V1. INSERVICE –> Control Module
1 1 12 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 13 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 14 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 15 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 16 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 17 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 18 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 19 GTGO GTGOE 8 110301 V1. INSERVICE
1 1 21 HUTQ HUTQ 4 100101 V1. INSERVICE –> Uplink Module
1 1 22 HUTQ HUTQ 4 100101 V1. INSERVICE –> Uplink Module
OL01#
CHECKING OLT PROCESSOR AND MEMORY
OL01#show processor
Rack Shelf Slot CPU(5s) CPU(1m) CPU(5m) PhyMem(MB) Memory
——————————————————————————-
1 1 2 14% 13% 13% 256 55%
1 1 3 19% 21% 21% 1024 16%
1 1 4 14% 12% 12% 256 55%
1 1 5 10% 9% 10% 256 55%
1 1 6 11% 11% 11% 256 55%
1 1 7 9% 11% 11% 256 55%
1 1 8 11% 10% 10% 256 55%
1 1 9 10% 9% 10% 256 55%
1 1 10 1% 1% 1% 1024 26%
1 1 11 2% 1% 1% 1024 27%
1 1 12 11% 10% 10% 256 55%
1 1 13 9% 10% 10% 256 55%
1 1 14 9% 11% 11% 256 55%
1 1 15 9% 11% 11% 256 55%
1 1 16 9% 11% 11% 256 55%
1 1 17 12% 11% 11% 256 55%
1 1 18 9% 11% 11% 256 55%
1 1 19 12% 11% 11% 256 55%
1 1 21 13% 12% 12% 32 21%
1 1 22 13% 12% 12% 32 21%
OL01#
CHECKING OLT TEMPERATURE
OL01#show temperature
Card Temperature:
——————————————-
Slot Temperature(Celsius scale)
——————————————-
0 N/A.
1 N/A.
2 35
3 32
4 33
5 35
6 36
7 35
8 34
9 37
10 20
11 20
12 34
13 35
14 36
15 36
16 35
17 35
18 35
19 32
20 N/A.
21 N/A.
22 N/A.
——————————————-
OL01#
CHECKING OLT PER SLOT
OL01#show card slotno 12
Config-Type : GTGO Status : INSERVICE
Real-Type : GTGOE Serial-Number : 272
Port-Number : 8 BootROM-VER : V1.2.024 14:17:00
PCB-VER : 11 Software-VER : V1.2.:52:53
Cpld-VER : V1
Phy-Mem-Size : 256MB Main-CPU : PowerPC Processor
Cpu-Usage : 10% Cpu-Alarm-Threshold : 100%
Mem-Usage : 55% Mem-Alarm-Threshold : 100%
Uptime : 259 Day , 11 Hours , 16 Minutes , 57 Second
OL01#
FINDING ONT BY SN NUMBER
OL01#sho gpon onu by sn ABCDEFGHIJ
SearchResult
—————–
gpon-onu_1/4/1:2
OL01#
CHECKING ONT STATUS
OL01#sho gpon onu sta gpon-olt_1/4/1 2
OnuIndex Admin State OMCC State O7 State Phase State
—————————————————————————-
gpon-onu_1/4/1:2 enable enable operation working –> modem normal
ONU Number: 1/1
OL01#
CHECKING ONT UPTIME AND ONT HISTORY LOGS
OL01#sho gpon onu detail-info gpon-onu_1/4/1:2
ONU interface: gpon-onu_1/4/1:2
Name: ONU-1:2
Type: ZTEG-F660 –> ONT type 4 ports
State: ready
Admin state: enable
Phase state: working
Authentication mode: sn
SN Bind: enable with SN check
Serial number: ABCDEFGHIJ
Password:
Device ID:
Description: IRONMAN
Vport mode: gemport
DBA Mode: Hybrid
ONU Status: enable
OMCI BW Profile: enable
Line Profile: N/A
Service Profile: N/A
Alarm Profile: N/A
Performance Profile: N/A
ONU Distance: 2510m
Online Duration: 17h 28m 14s –> Online Duration
FEC: none
——————————————
Authpass Time OfflineTime Cause
1 2016-12-31 16:16:25 2017-01-04 03:34:37 DyingGasp –> ont Off
2 2017-01-04 03:35:51 2017-01-04 23:25:01 DyingGasp
3 2017-01-04 23:30:09 2017-01-05 11:08:53 DyingGasp
4 2017-01-05 11:11:17 2017-01-08 08:12:27 DyingGasp
5 2017-01-08 08:13:39 2017-01-10 10:42:57 LOS –> physical problem
6 2017-01-10 10:43:44 2017-01-11 00:25:41 DyingGasp
7 2017-01-11 00:27:11 2017-03-09 11:46:17 DyingGasp
8 2017-03-09 11:54:12 2017-03-15 18:53:03 DyingGasp
9 2017-03-15 19:28:56 2017-03-29 01:29:10 DyingGasp
10 2017-03-29 01:30:18 0000-00-00 00:00:00
OL01#
CHECKING ONT MAC ADDRESS
OL01#sho mac gpon onu gpon-onu_1/4/1:2
Total mac address : 2
Mac address Vlan Type Port Vc
————————————————————————
KEREN.KEREN.KEREN 212 Dynamic gpon-onu_1/4/1:2 vport 1
BEKEN.BEKEN.BEKEN 121 Dynamic gpon-onu_1/4/1:2 vport 2
OL01#
CHECKING ONT POWER
OL01#sho pon power attenuation gpon-onu_1/4/1:2
OLT ONU Attenuation
————————————————————————–
up Rx :-19.153(dbm) Tx:2.728(dbm) 21.881(dB)
down Tx :3.769(dbm) Rx:-18.890(dbm) 22.659(dB)
OL01#
CHECKING ONT VERSION
OL01#sho gpon remote-onu equip gpon-onu_1/4/1:2
Vendor ID: ZTEG
Version: V5.2
SN: ABCDEFGHIJ
Admin status: unlock
Battery backup: false
Security Mode: aes
Product code: 0
TotalPrioQueueNum: 64
TotalTrafficSchNum: 8
TrafficMgmtOption: priority-rate-controlled
OperState: enable
EquipID: F63.2 –> vERSION
OMCC Version: a0
Security Capability: aes
Model: F6
Survival time: N/A
TotalGemPortNum: 256
SysUpTime: 0
OL01#
CHECKING ONT IP (ROUTING MODE)
In This case, We used ip-host 1
in one ONT we can create 4 IP-HOST management
OL01#sho gpon remote-onu ip-host gpon-onu_1/4/1:2
Host ID: 1
HostName: omci_ipv4_dhcp_1
Identify:
IP: 0.0.0.0
Mask: 0.0.0.0
Gateway: 0.0.0.0
Primary DNS: 0.0.0.0
Second DNS: 0.0.0.0
DHCP-enable: true
Ping-response: true
Traceroute-response:true
MAC: KEREN.KEREN.KEREN
CurIP: 1.2.3.4
CurMask: 255.255.255.0
CurGateway: 1.2.3.4
CurPriDNS: 6.6.6.6
CurSecDNS: 7.7.7.7
CHECKING ONT PORT STATUS
OL01#sho gpon remote-onu interface eth gpon-onu_1/4/1:2
Interface: eth_0/1
Speed status: auto
Operate status:disable
Admin status: unlock –> should be unlock
Arc: 0
Arc-interval 0
Expect-type: 0
Speed config: auto
Eth-loop: disable
Max-frame: 1632
Pause-time: 0
Wiring : dce
BridgeOrIP: either
PPPOE-filter: disable
Power-control: disable
CHECKING ONT CONFIGURATION
OL01#sho run int gpon-onu_1/4/1:2
Building configuration…
!
interface gpon-onu_1/4/1:2
descriptionIRONMAN
tcont 1 profile share
gemport 1 name ngenet unicast tcont 1 dir both
gemport 1 traffic-limit downstream 300m
gemport 2 name nontonfelm unicast tcont 1 dir both
gemport 2 traffic-limit downstream 300m
gemport 3 name tilpun unicast tcont 1 dir both
gemport 3 traffic-limit downstream 300m
switchport mode hybrid vport 1
switchport vlan 212 tag vport 1
switchport mode hybrid vport 2
switchport vlan 121 tag vport 2
switchport mode hybrid vport 3
switchport vlan 122 tag vport 3
!
end
OL01#sho onu run con gpon-onu_1/4/1:2
pon-onu-mng gpon-onu_1/4/1:2
flow 2 switch switch_0/1
flow 3 switch switch_0/1
flow mode 1 tag-filter vid-filter untag-filter discard
flow mode 2 tag-filter vid-filter untag-filter discard
flow mode 3 tag-filter vid-filter untag-filter discard
flow 1 priority 0 vid 212
flow 2 priority 0 vid 121
flow 3 priority 0 vid 122
gemport 1 flow 1
gemport 2 flow 2
gemport 3 flow 3
switchport-bind switch_0/1 iphost 1
ip-host 1 dhcp-enable true ping-response true traceroute-response true
vlan-filter-mode iphost 1 tag-filter vid-filter untag-filter discard
vlan-filter iphost 1 priority 0 vid 212
vlan port eth_0/2 mode tag vlan 121
vlan port eth_0/3 mode tag vlan 122
dhcp-ip ethuni eth_0/2 from-internet –> bridging mode
dhcp-ip ethuni eth_0/3 from-internet –> bridging mode
!
OL01#
REBOOT ONT
OL01#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#reboot
RESET FACTORY ONT
OL01#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#restore factory
HOW TO LOCK / SHUTDOWN THIRD PORT ONT
OL01#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#interface eth eth_0/3 state lock
HOW TO UNLOCK PORT ONT
OL01#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#interface eth eth_0/3 state unlock
HOW TO RELEASE RENEW ONT AS DHCP CLIENT
OL01#config t
Enter configuration commands, one per line. End with CTRL/Z.
OL01(config)#pon-onu
OL01(config)#pon-onu-mng gpon-onu_1/4/1:2
OL01(gpon-onu-mng)#ip-host 1 dhcp-enable false ping-response false traceroute-response false
OL01(gpon-onu-mng)#ip-host 1 dhcp-enable true ping-response true traceroute-response true
CHECKING RX LEVEL FOR OLT UPLINK
Make Sure , There is no CRC Counting at your Uplink Interface :p
OL01#sho int optical-module-info xgei_1/21/1
Optical module information:xgei_1/21/1
Basic-info:
Vendor-Name : SOU Vendor-Pn : SPP1
Vendor-Sn : D9 Version-Lev : 10
Production-Date: 13 Module-Type : 10GBASE-LR
Wavelength : 1310 (nm) Connector : LC
Diagnostic-info:
RxPower : -10.1(dbm) TxPower : -1.7(dbm)
Bias-Current : 25.724 (mA) Laser-Rate : 103(100Mb/s)
Temperature : 24.184 (c) Supply-Vol : 3.324(v)
Alarm-thresh: –> Threshold
RxPower-Upper : 3 (dbm) RxPower-Lower : -34(dbm)
TxPower-Upper : 9 (dbm) TxPower-Lower : -14(dbm)
Bias-Upper : 131(mA) Bias-Lower : 0 (mA)
Voltage-Upper : 7 (v) Voltage-Lower : 0 (v)
Temperature-Upper: 90 (c) Temperature-Lower: -45(c)
OL01#
RESET SLOT
OL01#reset-card slotno 12
SWAP
Use This for First Level Handling when you get Anomaly Process.
sometimes it can help you, but sometime isn’t.
OL01#swap
CHECKING VLAN SUMMARY
OL01#sho vlan sum
All created vlan num: 3
Details are following:
111, 222 , 333
OL01#
OL01#sho vlan 111
vlanid :111
name :VLAN00111
description :N/A
multicast-packet:flood-unknown
tpid:0x8100
port(untagged):
port(tagged):
gpon-onu_1/2/8:128:1
xgei_1/22/1
sg1
OL01#
If U want to Explore More about other, My advice is using “?” symbol.