Skip to content

Latest commit

 

History

History
277 lines (243 loc) · 10.3 KB

api.md

File metadata and controls

277 lines (243 loc) · 10.3 KB

API and Resource Definitions

BareMetalHost

Metal³ introduces the concept of BareMetalHost resource, which defines a physical host and its properties. The BareMetalHost embeds two well differentiated sections, the bare metal host specification and its current status.

BareMetalHost spec

The BareMetalHost's spec defines the desire state of the host. It contains mainly, but not only, provisioning details.

Spec fields

  • bmc -- The connection information for the BMC (Baseboard Management Controller) on the host.

    • address -- The URL for communicating with the BMC controller, based on the provider being used, the URL will look as follows:

      • IPMI
        • ipmi://<host>:<port>, an unadorned <host>:<port> is also accepted and the port is optional, if using the default one (623).
      • Dell iDRAC
        • idrac:// (or idrac+http:// to disable TLS).
      • Fujitsu iRMC
        • irmc://<host>:<port>, where <port> is optional if using the default.
      • Redfish
        • redfish:// (or redfish+http:// to disable TLS), the hostname or IP address, and the path to the system ID are required, for example redfish://myhost.example/redfish/v1/Systems/MySystemExample
    • credentialsName -- A reference to a secret containing the username and password for the BMC.

  • online -- A boolean indicating whether the host should be powered on (true) or off (false). Changing this value will trigger a change in power state on the physical host.

  • consumerRef -- A reference to another resource that is using the host, it could be empty if the host is not being currently used. For example, a Machine resource when the host is being used by the machine-api.

  • externallyProvisioned -- A boolean indicating whether the host provisioning and deprovisioning are managed externally. When set, the host's power status and hardware inventory will be monitored but no provisioning or deprovisioning operations are performed on the host.

  • image -- Holds details for the image to be deployed on a given host.

    • url -- The URL of an image to deploy to the host.
    • checksum -- The actual checksum or a URL to a file containing the checksum for the image at image.url.
  • userData -- A reference to the Secret containing the cloudinit user data and its namespace, so it can be attached to the host before it boots for configuring different aspects of the OS (like networking, storage, ...).

  • description -- A human-provided string to help identify the host.

BareMetalHost status

Moving onto the next block, the BareMetalHost's status which represents the host's current state. Including tested credentials, current hardware details, etc.

Status fields

  • goodCredentials -- A reference to the secret and its namespace holding the last set of BMC credentials the system was able to validate as working.

  • triedCredentials -- A reference to the secret and its namespace holding the last set of BMC credentials that were sent to the provisioning backend.

  • lastUpdated -- The timestamp of the last time the status of the host was updated.

  • operationalStatus -- The status of the server. Value is one of the following:

    • OK -- Indicates all the details for the host are known and working, meaning the host is correctly configured and manageable.
    • discovered -- Implies some of the host's details are either not working correctly or missing. For example, the BMC address is known but the login credentials are not.
    • error -- Indicates the system found some sort of irrecuperable error. Refer to the errorMessage field in the status section for more details.
  • errorMessage -- Details of the last error reported by the provisioning backend, if any.

  • hardware -- The details for hardware capabilities discovered on the host. These are filled in by the provisioning agent when the host is registered.

    • nics -- List of network interfaces for the host.
      • name -- A string identifying the network device, e.g. nic-1.
      • mac -- The MAC address of the NIC.
      • ip -- The IP address of the NIC, if one was assigned when the discovery agent ran.
      • speedGbps -- The speed of the device in Gbps.
      • vlans -- A list holding all the VLANs available for this NIC.
      • vlanId -- The untagged VLAN ID.
      • pxe -- Whether the NIC is able to boot using PXE.
    • storage -- List of storage (disk, SSD, etc.) available to the host.
      • name -- A string identifying the storage device, e.g. disk 1 (boot).
      • rotational -- Either true or false, indicates whether the disk is rotational.
      • sizeBytes -- Size of the storage device.
      • serialNumber -- The device's serial number.
    • cpu -- Details of the CPU(s) in the system.
      • arch -- The architecture of the CPU.
      • model -- The model string.
      • clockMegahertz -- The speed in GHz of the CPU.
      • flags -- List of CPU flags, e.g. 'mmx','sse','sse2','vmx', ...
      • count -- Amount of these CPUs available in the system.
    • firmware -- Contains BIOS information like for instance its vendor and version.
    • systemVendor -- Contains information about the host's manufacturer, the productName and serialNumber.
    • ramMebibytes -- The host's amount of memory in Mebibytes.
  • hardwareProfile -- The name of the hardware profile that matches the hardware discovered on the host. These details are saved to the Hardware section. If the hardware does not match any known profile, the value unknown will be set on this field and is used by default. In practice, this only affects which device the OS image will be written to. The following are the current supported hardwareProfile settings and their corresponding root devices.

    hardwareProfile Root Device
    unknown /dev/sda
    libvirt /dev/vda
    dell HCTL: 0:0:0:0
    dell-raid HCTL: 0:2:0:0

    NOTE: These are subject to change.

  • poweredOn -- Boolean indicating whether the host is powered on. See online on the BareMetalHost's Spec.

  • provisioning -- Settings related to deploying an image to the host.

    • state -- The current state of any ongoing provisioning operation. The following are the currently supported ones:
      • <empty string> -- There is no provisioning happening, at the moment.
      • registration error -- The details for the host's BMC are either incorrect or incomplete therfore the host could not be managed.
      • registering -- The host's BMC details are being checked.
      • match profile -- The discovered hardware details on the host are being compared against known profiles.
      • ready -- The host is available to be consumed.
      • provisioning -- An image is being written to the host's disk(s).
      • provisioning error -- The image could not be written to the host.
      • provisioned -- An image has been completely written to the host's disk(s).
      • externally provisioned -- Metal³ does not manage the image on the host.
      • deprovisioning -- The image is being wiped from the host's disk(s).
      • inspecting -- The hardware details for the host are being collected by an agent.
      • power management error -- An error was found while trying to power the host either on or off.

BareMetalHost Example

The following is a complete example from a running cluster of a BareMetalHost resource (in YAML), it includes its specification and status sections:

apiVersion: metal3.io/v1alpha1
kind: BareMetalHost
metadata:
  creationTimestamp: "2019-09-20T06:33:35Z"
  finalizers:
  - baremetalhost.metal3.io
  generation: 2
  name: bmo-master-0
  namespace: bmo-project
  resourceVersion: "22642"
  selfLink: /apis/metal3.io/v1alpha1/namespaces/bmo-project/baremetalhosts/bmo-master-0
  uid: 92b2f77a-db70-11e9-9db1-525400764849
spec:
  bmc:
    address: ipmi://10.10.57.19
    credentialsName: bmo-master-0-bmc-secret
  bootMACAddress: 98:03:9b:61:80:48
  consumerRef:
    apiVersion: machine.openshift.io/v1beta1
    kind: Machine
    name: bmo-master-0
    namespace: bmo-project
  externallyProvisioned: true
  hardwareProfile: default
  image:
    checksum: http://172.16.1.100/images/myOSv1/myOS.qcow2.md5sum
    url: http://172.16.1.100/images/myOSv1/myOS.qcow2
  online: true
  userData:
    name: bmo-master-user-data
    namespace: bmo-project
status:
  errorMessage: ""
  goodCredentials:
    credentials:
      name: bmo-master-0-bmc-secret
      namespace: bmo-project
    credentialsVersion: "5562"
  hardware:
    cpu:
      arch: x86_64
      clockMegahertz: 2000
      count: 40
      flags: []
      model: Intel(R) Xeon(R) Gold 6138 CPU @ 2.00GHz
    firmware:
      bios:
        date: 12/17/2018
        vendor: Dell Inc.
        version: 1.6.13
    hostname: bmo-master-0.localdomain
    nics:
    - ip: 172.22.135.105
      mac: "00:00:00:00:00:00"
      model: unknown
      name: eno1
      pxe: true
      speedGbps: 25
      vlanId: 0
    ramMebibytes: 0
    storage: []
    systemVendor:
      manufacturer: Dell Inc.
      productName: PowerEdge r460
      serialNumber: ""
  hardwareProfile: ""
  lastUpdated: "2019-09-20T07:03:23Z"
  operationalStatus: OK
  poweredOn: true
  provisioning:
    ID: a4438010-3fc6-4c5c-b570-900bbe85da57
    image:
      checksum: ""
      url: ""
    state: externally provisioned
  triedCredentials:
    credentials:
      name: bmo-master-0-bmc-secret
      namespace: bmo-project
    credentialsVersion: "5562"

And here it is the secret bmo-master-0-bmc-secret holding the host's BMC credentials:

---
apiVersion: v1
kind: Secret
metadata:
  name: bmo-master-0-bmc-secret
type: Opaque
data:
  username: YWRtaW4=
  password: cGFzc3dvcmQ=

Triggering Provisioning

Several conditions must be met in order to initiate provisioning.

  1. The host spec.image.url field must contain a URL for a valid image file that is visible from within the cluster and from the host receiving the image.
  2. The host must have online set to true so that the operator will keep the host powered on.

To initiate deprovisioning, clear the image URL from the host spec.