Model | 064882 |
Vendor | Legrand |
Description | Cable outlet with pilot wire and consumption measurement |
Exposes | device_mode, cable_outlet_mode, switch (state, state), power, power_apparent, power_on_behavior, linkquality |
Picture |
Step 1 - Reset the device, press the reset button for 8 seconds (it's the hole on the device). The light will be static red when the reset is complete. Step 2 - Allow join on your coordinator and simple press (not a long press) the reset button. The light blinks green in pairing mode. Troobleshooting: The Legrand bridge shall be power off if you have one. If it is on, the interview will complete with zigbee2MQTT, but the device won't communicate after that.
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
-
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
Value can be found in the published state on the device_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"device_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"device_mode": NEW_VALUE}
.
If value equals pilot_on
device mode is ON, if pilot_off
OFF.
Value can be found in the published state on the cable_outlet_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"cable_outlet_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"cable_outlet_mode": NEW_VALUE}
.
The possible values are: comfort
, comfort-1
, comfort-2
, eco
, frost_protection
, off
.
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It's not possible to write (/set
) this value.
The unit of this value is W
.
Instantaneous measured apparent power.
Value can be found in the published state on the power_apparent
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is VA
.
Controls the behavior when the device is powered on. Works only when the pilot wire is deactivated.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, previous
, on
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.