DobsonFlagOz.ini Version: 02.09.2021 [Header line, version maybe read]
[Period]
dd.mm.yyyy [Period Begin (dd.mm.yyyy)] (1)
dd.mm.yyyy [Period End (dd.mm.yyyy)] (1)
auto [Type of flagging/unflagging (auto/manu/reset)] (2)
[Instruments]
101,062,051 [Instrument Identifier(s) 'iii'] (3)
Cal21a,Cal21a,Cal21a [Calibration(s)] (3)
C:\PMOD\Dobson\Data\AE\iii\Calxxx\yyyy\ [Path Input Datafile(s)] (4)
C:\PMOD\Dobson\Data\AE\iii\Calxxx\yyyy\ [Path Output Datafile(s)] (4)
SgCorLst_Diii_yyyy_auto.txt [Name of auto flaglist output file] (4)
SgCorLst_Dobs_yyyy_manu.txt [Name of manu flaglist input file] (4)
C:\PMOD\Ozone\Flagging [Path name of flaglist input/output files] (4)
[Filters]
3 [Number of Wavelengths (1..3)]
C-D-A [Wavelength Sequence]
drval+poly4+consec [Auto flagging input data] (5)
poly4 [Diff Reference (dayoz/polyN/consec/none)]
1.60,2.50,1.25 [RelDiff Dayoz Limit [%] for C-D-A]
0.15,0.12,0.25 [AbsDiff dRval Limit [dR] for C-D-A]
0.80,2.00,1.00 [RelDiff polyN Limit [%] for C-D-A]
1.00,2.00,1.00 [RelDiff consecutive Ozone Limit [%] for C-D-A
10.0 [Delta T for consecutive measurements [min]] (6)
22 [Minimal sun intensity]
3.800 [Maximal airmass]
# 'DobsonFlagOz.R' flags the total ozone measurements of a Dobson, reading the data
# from the 'AEyyyymmdd.iii' files, results are written to an equal named file located
# in the same or annother directory
(1) If 'Period Begin' and/or 'Period End' is "dd.mm.yyyy" the proper dates are read from file
"DataPeriod.ini" (located in the same directory as the calling program)
(2) Type of flagging/unflagging: 0 or reset reset all flags
1 or auto set automatic flags, values are written to
the flaglist file (output)
2 or manu set/reset manual flags/unflags accordingly to
the flaglist file (input)
standard filenames of flaglist-files:
- auto SgCorLst_Diii_yyyy_auto.txt (output-file)
- manu SgCorLst_Dobs_yyyy_manu.txt (input-file)
(3) More than one instrument possible, separated by comma, e.g.: 062,101,051;
in the latter case 'Calxxx' must be written as e.g.: 'Calxx1,Calxx2,Calxx3'
(4) If a instrument identifier in the path or the filename is written as 'iii' the
Instrument identifier string will replace the 'iii' string
If a year number in the path is written as 'yyyy' the appropriate year will be
set in a single or multiple year proceeding at this position
If a calibration identifier in the path or the filename is written as 'Calxxx' the
Calibration info string from line 8 will replace the 'Calxxx' string
(5) combination of 'drval' and 'consec' with any other type of rel diff also possible:
e.g. 'drval+poly4+consec'
Standard RelDiff Limits [%] from D051 2016 01-06 RDnarrow
C D A
1.60 2.50 1.25 RelDiff Dayoz Limit [%]
0.80 2.00 0.50 RelDiff polyN Reg Limit [%]
0.80 2.00 0.50 RelDiff Ozone consecut. Limit [%]
(6) time in minutes, e.g. 8.0; 0 if no test of consecutive measurements is required