raise error and quit sampling if actual sampling rate deviates too far from requested #19

Open
neuromusic opened this issue Feb 25, 2016 · 0 comments

Comments

@neuromusic
Copy link
Member

I ran into a bug where the sampling configuration was returning 625Hz despite the 20,000Hz requested rate, but I had no idea until I went to look at the data.

FML

We should check the returned rate and shut it down if it deviates more than 10%