You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This property indicates the ON/OFF status. If the ON/OFF status is ON, this value is true, otherwise false.
Operation power-saving
EPC: 0x8F
Property
Type
Description
mode
Boolean
This property indicates the power-saving operation mode. If in power-saving mode, this value is true, otherwise false.
Operation mode setting
EPC: 0xB0
Property
Type
Description
mode
Number
This property indicates the operation mode as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Automatic
自動
2
Cooling
冷房
3
Heating
暖房
4
Dehumidification
除湿
5
Air circulator
送風
0
Other
その他
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Automatic temperature control setting
EPC: 0xB1
Property
Type
Description
mode
Boolean
This property indicates the power-saving operation mode. If in power-saving mode, this value is true, otherwise false.
Normal/highspeed/silent operation setting
EPC: 0xB2
Property
Type
Description
mode
Number
This property indicates the type of operation as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Normal operation
通常運転
2
High-speed operation
急速
3
Silent operation
静音
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Set temperature value
EPC: 0xB3
Property
Type
Description
temperature
Number
This property indicates the current temperature setting in the units of Celsius.
The value of the temperature must be an integer in the range of 0 to 50 (Celsius).
Set value of relative humidity in dehumidifying mode
EPC: 0xB4
Property
Type
Description
humidity
Number
This property indicates the relative humidity setting for the "dehumidification" mode in the units of %.
The value of the humidity must be an integer in the range of 0 to 100 (%).
Set temperature value in cooling mode
EPC: 0xB5
Property
Type
Description
temperature
Number
This property indicates the temperature setting for the "cooling" mode in the units of Celsius.
The value of the temperature must be an integer in the range of 0 to 50 (Celsius).
Set temperature value in heating mode
EPC: 0xB6
Property
Type
Description
temperature
Number
This property indicates the temperature setting for the "heating" mode in the units of Celsius.
The value of the temperature must be an integer in the range of 0 to 50 (Celsius).
Set temperature value in dehumidifying mode
EPC: 0xB7
Property
Type
Description
temperature
Number
This property indicates the temperature setting for the "dehumidification" mode in the units of Celsius.
The value of the temperature must be an integer in the range of 0 to 50 (Celsius).
Rated power consumption
EPC: 0xB8
Property
Type
Description
cooling
Number
This property indicates the rated power consumption in operation mode of "cooling" in the units of Watt (W).
heating
Number
This property indicates the rated power consumption in operation mode of "heating" in the units of Watt (W).
dehumidifying
Number
This property indicates the rated power consumption in operation mode of "dehumidifying" in the units of Watt (W).
blast
Number
This property indicates the rated power consumption in operation mode of "blast" in the units of Watt (W).
The value of each property must be an integer in the range of 0 to 65533 (W).
Measured value of current consumption
EPC: 0xB9
Property
Type
Description
current
Number
This property indicates the measured value of current consumption in the units of A.
The value of the current must be an float in the range of 0 to 6553.3 (A).
Measured value of room relative humidity
EPC: 0xBA
Property
Type
Description
humidity
Number
This property indicates the measured value of room relative humidity in the units of %.
The value of the humidity must be an integer in the range of 0 to 100 (%).
Measured value of room temperature
EPC: 0xBB
Property
Type
Description
temperature
Number
This property indicates the measured value of room temperature in the units of Celsius.
The value of the temperature must be an integer in the range of -127 to 125 (Celsius).
Set temperature value of user remote control
EPC: 0xBC
Property
Type
Description
temperature
Number
This property indicates the set temperature value of user remote control in the units of Celsius.
The value of the temperature must be an integer in the range of 0 to 50 (Celsius).
Measured cooled air temperature
EPC: 0xBD
Property
Type
Description
temperature
Number
This property indicates the measured cooled air temperature at the outlet in the units of Celsius.
The value of the temperature must be an integer in the range of -127 to 125 (Celsius).
Measured cooled air temperature
EPC: 0xBE
Property
Type
Description
temperature
Number
This property indicates the measured outdoor air temperature in the units of Celsius.
The value of the temperature must be an integer in the range of -127 to 125 (Celsius).
Relative temperature setting
EPC: 0xBF
Property
Type
Description
temperature
Number
This property indicates the relative temperature relative to the target temperature for an air conditioner operation mode in the units of Celsius.
The value of the temperature must be an float in the range of -12.7 to 12.5 (Celsius).
Air flow rate setting
EPC: 0xA0
Property
Type
Description
level
Number
This property indicates the air flow rate as a number in the range of 1 to 8. If this value is 0, it means that the function to automatically control the air flow rate is used.
The value of the level must be an integer in the range of 0 to 8.
Automatic control of air flow direction setting
EPC: 0xA1
Property
Type
Description
mode
Number
This property indicates whether or not to use the automatic air flow direction control and the plane(s) (vertical and/or horizontal) in which the automatic air flow direction control function is to be used function as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Automatic
AUTO
2
Non-automatic
非AUTO
3
Automatic (vertical)
上下AUTO
4
Automatic (horizontal)
左右AUTO
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Automatic swing of air flow setting
EPC: 0xA3
Property
Type
Description
mode
Number
This property indicates whether or not to use the automatic air flow swing function and the plane(s) (vertical and/or horizontal) in which the automatic air flow swing function is to be used as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
0
OFF
OFF
1
Vertical
上下
2
Horizontal
左右
3
Vertical and horizontal
上下左右
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Air flow direction (vertical) setting
EPC: 0xA4
Property
Type
Description
mode
Number
This property indicates the air flow direction in the vertical plane by selecting a pattern from among the 5 predefined patterns as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Uppermost
上
2
Lowermost
下
3
Central
中央
4
Midpoint between uppermost and central
上中
5
Midpoint between lowermost and central
下中
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Air flow direction (horizontal) setting
EPC: 0xA5
Property
Type
Description
directions
Array
This property indicates the air flow direction(s) in the horizontal plane by selecting a pattern from among the 31 predefined patterns.
desc
String
See the description below.
The ECHONET Lite specification defines 5 directions for this EPC: "left", "middle between left and center", "center", "middle between center and right", and "right". The value of the directions is an Array consisting of 5 boolean values (true or false) corresponding to each direction.
[true,true,false,false,false]
If the value is an Array described above, the air flow directions are 2 directions: "left" and "middle between left and center".
The value of the desc is a text representation of the directions property. The value of the value above is expressed as "||---".
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Special state
EPC: 0xAA
Property
Type
Description
state
Number
This property indicates if the air conditioner is in a "special" state (i.e. the "defrosting", "preheating" or "heat removal" state) as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
0
Normal operation
通常状態
1
Defrosting
除霜状態
2
Preheating
予熱状態
3
Heat removal
排熱状態
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Non-priority state
EPC: 0xAB
Property
Type
Description
state
Boolean
This property indicates whether the air conditioner is in a "non-priority" state or not. If the air conditioner is in "non-priority" stat, this value is true. Otherwise, it is false.
Ventilation function setting
EPC: 0xC0
Property
Type
Description
mode
Number
This property indicates whether or not to use the ventilation function as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
ON (outlet direction)
ON(排気方向)
2
OFF
OFF
3
ON (intake direction)
ON(吸気方向)
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Humidifier function setting
EPC: 0xC1
Property
Type
Description
mode
Boolean
This property indicates whether or not to use the humidifier function. If the humidifier function is used, this value is true. Otherwise, it is false.
Ventilation air flow rate setting
EPC: 0xC2
Property
Type
Description
level
Number
This property indicates the ventilation air flow rate by selecting a level from among the predefined levels in the range of 1 to 8. If this value is 0, it means that the automatic control of ventilation air flow rate is used.
The value of the level must be an integer in the range of 0 to 8.
Ventilation air flow rate setting
EPC: 0xC4
Property
Type
Description
level
Number
This property indicates the degree of humidification to achieve by selecting a level from among the predefined levels in the range of 1 to 8. If this value is 0, it means that the automatic control of the degree of humidification is used.
The value of the level must be an integer in the range of 0 to 8.
Mounted air cleaning method
EPC: 0xC6
Property
Type
Description
dust
Boolean
This property indicates whether the electrical dust collection method is mounted or not as an air cleaning method. If it is mounted, this value is true. Otherwise, this value is false.
ion
Boolean
This property indicates whether the cluster ion method is mounted or not as an air cleaning method. If it is mounted, this value is true. Otherwise, this value is false.
Air purifier function setting
EPC: 0xC7
Property
Type
Description
dust_mode
Boolean
This property indicates whether or not to use the electrical dust collection-based air purifier function. If it is used, this value is true. Otherwise, this value is false.
dust_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the electrical dust collection-based air purification. If it is automatic, this value is true. If it is non-automatic, this value is false.
dust_level
Number
This property indicates the electrical dust collection-based air purification level as an integer in the range of 0 to 7.
ion_mode
Boolean
This property indicates whether or not to use the cluster ion-based air purifier function. If it is used, this value is true. Otherwise, this value is false.
ion_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the cluster ion-based air purification. If it is automatic, this value is true. If it is non-automatic, this value is false.
ion_level
Number
This property indicates the cluster ion-based air purification level as an integer in the range of 0 to 7.
Mounted air refresh method
EPC: 0xC8
Property
Type
Description
minus
Boolean
This property indicates whether the minus ion method is mounted or not as an air refresh method. If it is mounted, this value is true. Otherwise, this value is false.
cluster
Boolean
This property indicates whether the cluster ion method is mounted or not as an air cleaning method. If it is mounted, this value is true. Otherwise, this value is false.
Air refresher function setting
EPC: 0xC9
Property
Type
Description
minus_mode
Boolean
This property indicates whether or not to use the minus ion-based air refresher function. If it is used, this value is true. Otherwise, this value is false.
minus_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the minus ion-based air refresher. If it is automatic, this value is true. If it is non-automatic, this value is false.
minus_level
Number
This property indicates the minus ion-based air refreshing level as an integer in the range of 0 to 7.
cluster_mode
Boolean
This property indicates whether or not to use the cluster ion-based air refresher function. If it is used, this value is true. Otherwise, this value is false.
cluster_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the cluster ion-based air refresher. If it is automatic, this value is true. If it is non-automatic, this value is false.
cluster_level
Number
This property indicates the cluster ion-based air refreshing level as an integer in the range of 0 to 7.
Mounted self-cleaning method
EPC: 0xCA
Property
Type
Description
ozone
Boolean
This property indicates whether the ozone cleaning method is mounted or not as an self-cleaning method. If it is mounted, this value is true. Otherwise, this value is false.
drying
Boolean
This property indicates whether the drying cleaning method is mounted or not as an self-cleaning method. If it is mounted, this value is true. Otherwise, this value is false.
Air refresher function setting
EPC: 0xCB
Property
Type
Description
ozone_mode
Boolean
This property indicates whether or not to use the ozone-based self-cleaning function. If it is used, this value is true. Otherwise, this value is false.
ozone_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the ozone-based self-cleaning. If it is automatic, this value is true. If it is non-automatic, this value is false.
ozone_level
Number
This property indicates the ozone-based self-cleaning level as an integer in the range of 0 to 7.
drying_mode
Boolean
This property indicates whether or not to use the ozone-based self-cleaning function. If it is used, this value is true. Otherwise, this value is false.
drying_state
Boolean
This property indicates whether or not to use the function to automatically control the degree of the drying-based self-cleaning. If it is automatic, this value is true. If it is non-automatic, this value is false.
drying_level
Number
This property indicates the drying-based self-cleaning level as an integer in the range of 0 to 7.
Special function setting
EPC: 0xCC
Property
Type
Description
mode
Number
This property indicates whether or not to use the "special function" as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
0
No setting
設定なし
1
Clothes dryer function
衣類乾燥
2
Condensation suppressor function
結露抑制
3
Mite and mold control function
ダニカビ抑制
4
Active defrosting function
強制除霜
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Operation status of components
EPC: 0xCD
This property indicates the operation status of components of the air conditioner in a bitmap format.
Property
Type
Description
compressor
Boolean
This property indicates whether the compressor is operating or not. If it is operating, this value is true. Otherwise, this value is false.
thermostat
Boolean
This property indicates whether the thermostat is in the state of "ON" or not ("OFF"). If it is in the state of "ON", this value is true. If it is in the state of "OFF", this value is false.
Thermostat setting override function
EPC: 0xCE
Property
Type
Description
mode
Number
This property indicates whether or not to allow the air conditioner to operate ignoring its thermostat setting as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
0
Normal setting
通常設定
1
ON
ON
2
OFF
OFF
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Air purification mode setting
EPC: 0xCF
Property
Type
Description
mode
Boolean
This property indicates the air purification mode setting (ON or OFF). If it is set to "ON", this value is true. If it is set to "OFF", this value is false.
Buzzer
EPC: 0xD0
Property
Type
Description
mode
Boolean
This property is used to make the buzzer sound. If this property is set to true, the buzzer will sound. This property is allowed only true for the value.
ON timer-based reservation setting
EPC: 0x90
Property
Type
Description
mode
Number
This property indicates whether or not to use the ON timer (time-based reservation function, relative time-based reservation function or both) as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Both the time- and relative time-based reservation functions are ON
時刻予約,相対時間予約共に入
2
Both reservation functions are OFF
予約切
3
Time-based reservation function is ON
時刻予約のみ入り
4
Relative time-based reservation function is ON
相対時刻予約のみ入り
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
ON timer setting (time)
EPC: 0x91
Property
Type
Description
time
String
This property indicates the time for the time-based reservation function in the "HH:MM" format in the range of "00:00" to "23:59".
ON timer setting (relative time)
EPC: 0x92
Property
Type
Description
time
String
This property indicates the relative time for the relative time-based reservation function in the "HHH:MM" format in the range of "00:00" to 255:59".
OFF timer-based reservation setting
EPC: 0x94
Property
Type
Description
mode
Number
This property indicates whether or not to use the OFF timer (time-based reservation function, relative time-based reservation function or both) as a code.
desc
String
The description of the code.
The code map is as follows. Each code is shown as decimal representation:
Code
Description (English)
Description (Japanese)
1
Both the time- and relative time-based reservation functions are ON
時刻予約,相対時間予約共に入
2
Both reservation functions are OFF
予約切
3
Time-based reservation function is ON
時刻予約のみ入り
4
Relative time-based reservation function is ON
相対時刻予約のみ入り
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
OFF timer setting (time)
EPC: 0x95
Property
Type
Description
time
String
This property indicates the time for the time-based reservation function in the "HH:MM" format in the range of "00:00" to "23:59".
OFF timer setting (relative time)
EPC: 0x96
Property
Type
Description
time
String
This property indicates the relative time for the relative time-based reservation function in the "HHH:MM" format in the range of "00:00" to 255:59".
This property indicates the ON/OFF status. If the ON/OFF status is ON, this value is true, otherwise false.
Filter change notice
EPC: 0xE1
Property
Type
Description
notice
Boolean
Filter change time notice found/not found. If found, this value is true, otherwise false.
Air flow rate setting
EPC: 0xA0
Property
Type
Description
level
Number
This property indicates the air flow rate as a number in the range of 1 to 8. If this value is 0, it means that the function to automatically control the air flow rate is used.
The value of the level must be an integer in the range of 0 to 8.
Smoke (cigarette) detection status
EPC: 0xC1
Property
Type
Description
smoke
Boolean
This property indicates smoke (cigarette) detection status. If found, this value is true, otherwise false.
Optical catalyst operation setting
EPC: 0xC2
Property
Type
Description
catalyst
Boolean
This property indicates the Optical catalyst ON/OFF status. If the ON/OFF status is ON, this value is true, otherwise false.
Air pollution detection status
EPC: 0xC0
Property
Type
Description
pollution
Boolean
This property indicates air pollution detection status. If detected, this value is true, otherwise false.