-
Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathxapid.err
executable file
·59 lines (59 loc) · 2.69 KB
/
xapid.err
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
o socket:(:port:"PSTA"):10 e d logMessage("Cannot open socket",0,port) s stop=1 q
^-----
At column 12, line 55, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
. u socket:"PSTA"
^-----
At column 13, line 59, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
. j sub01^serverLink(port,logLevel):(:4:socket:socket):10 e d logMessage("Cannot spawn sub-process",1,port) q
^-----
At column 39, line 62, source module /xapi/scripts/serverLink.m
%GTM-E-JOBPARUNK, Job parameter unknown
o device:("TCP":"":port):10 e d logMessage("Cannot open socket",0,port) s stop=1 q
^-----
At column 12, line 75, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
. s socket=$zsocket(device)
^-----
At column 14, line 82, source module /xapi/scripts/serverLink.m
%GTM-E-INVFCN, Invalid function name
. u device:(::::::socket) ; Detach socket
^-----
At column 14, line 84, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
. c device:socket
^-----
At column 19, line 86, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARVALREQ, A value is required for this device parameter
s $et="i $estack=0 znspace """_$znspace_""" g error^serverLink"
^-----
At column 34, line 184, source module /xapi/scripts/serverLink.m
%GTM-E-INVSVN, Invalid special variable name
u socket:(::"STP")
^-----
At column 12, line 190, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
. u socket:(::"STP")
^-----
At column 14, line 200, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
s ucivol=$zu(0)
^-----
At column 12, line 230, source module /xapi/scripts/serverLink.m
%GTM-E-INVFCN, Invalid function name
s ucivolno=$zu(uci,vol)
^-----
At column 14, line 233, source module /xapi/scripts/serverLink.m
%GTM-E-INVFCN, Invalid function name
o device:("TCP":""::::socket) ; Attach socket
^-----
At column 12, line 241, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
u device:(:::$c(10))
^-----
At column 12, line 287, source module /xapi/scripts/serverLink.m
%GTM-E-DEVPARUNK, Deviceparameter unknown
150374122,start+7^serverLink,%GTM-E-ZGBLDIRACC, Cannot access global directory /data/xapi/scripts/xapi.gld. Cannot continue.,%SYSTEM-E-ENO2, No such file or directory
-sh: /xapi/scripts/xapid: No such file or directory
-sh: /xapi/scripts/xapid: No such file or directory