Add decoding of characteristics values for known BT SiG Assigned Numbers. #9
Comments
The hex numbers in your screenshot are non-printable characters and hence get displayed as square blocks (placeholder) when switched to ASCII. Only printable characters like letters, numbers, some special symbols get (can be) displayed as text. See readme.md under "Scan Data Panel". |
(HEX) CD00 =(HEX) 00CD = (DEC) 205 = 20.5 °C This is a standard format for transmitting numbers from thermometers. |
The ASCII checkbox is just about switching from raw hex numbers to (printable) ascii characters but will not take any specific encoding for service/characteristic assigned numbers into account. There exist gazillions of BT SiG Assigned Numbers for various sensor or other data, but this would be an endless job to implement all these. I could consider adding the most common ones (temperature likely would be one of those) in a future release. Thanks for raising this. |
Thanks. |
We keep this open since not yet implemented. |
Some data is not displayed correctly. (ASCII)
Example in the screenshot.
The text was updated successfully, but these errors were encountered: