I joined my RaspBee to the ZigBee network created by my Hue bridge. This page provides an overview per manufacturer of the ZigBee Devices connected to my Hue bridge, as reported by deCONZ. It lists the endpoints and clusters per device. Server clusters are in boldface.

TODO:

  • Try an make the RaspBee join a ZigBee network created by an Osram Lightify gateway.
  • Double check that the Lightify Gateway has FC0F and 0B04 client clusters for Device Setup and Electrical Measurement.
  • Try and make the RaspBee join a ZigBee network created by an innr gateway.

Philips

Hue Bridge

Here's the configuration for a second-generation Hue bridge:

Endpoint Profile Cluster Name
F2 ZGP 0061 unknown
0021 ZigBee Green Power Proxy
40 ZLL Control Bridge
1000 ZLL Commissioning
0019 OTAU
1000 ZLL Commissioning
0004 Groups
0005 Scenes
0000 Basic
0300 Color Control
0008 Level Control
0006 On/Off
41 ZHA Combined Interface
000F Binary Input (Basic)
0406 Occupancy Sensing
0402 Temperature Measurement
0405 Humidify Measurement
FC00 ? Device Setup
0400 Illuminance Measurement

Notes:

  • So the Hue bridge does talk ZHA?!
  • I suspect the Binary Input (Basic) is used for the buttonevent of the Hue dimmer switch.
  • Apparently they planned for a ZigBee version of the CLIPHumidity sensor? Then why no ZigBee version of the CLIPOpenClose sensor?
  • The Hue dimmer switch has a corresponding server for the FC00 cluster. Could it be for keeping track which lights are connected to the dimmer switch using touchlink? When connecting a previously standalone dimmer switch to a Hue bridge (using the Hue app), the bridge seems to "inherit" the lights from the dimmer switch.

Hue Lights

Here's the configuration for a Hue Extended Color Light:

Endpoint Profile Cluster Name
02 ZLL Extended Color Light
0000 Basic
0003 Identify
0004 Groups
0005 Scenes
0006 On/Off
0008 Level Control
0300 Color Control
1000 ZLL Commissioning
0019 OTAU
F2 ZGP 0061 unknown
0021 ZigBee Green Power Sink
0021 ZigBee Green Power Proxy

Notes:

  • A Hue Color Light and a Hue Color Temperature Lights have the same configuration. So does a Hue Dimmable Light, except that, of course, it misses the Color Control cluster.

Hue Motion Sensor

Here's the configuration for a Hue motion sensor:

Endpoint Profile Cluster Name
02 ZHA Occupancy Sensor
0000 Basic
0001 Power Configuration
0003 Identify
0406 Occupancy Sensing
0400 Illuminance Measurement
0402 Temperature Measurement
0019 OTAU
01 ZLL On/Off Sensor
0000 Basic
0000 Basic
0003 Identify
0004 Groups
0006 On/Off
0008 Level Control
0300 Color Control
0005 Scenes

Notes:

  • So the Hue motion sensor does talk ZHA?!
  • The 01 endpoint seems to suggest it could work standalone, without a Hue bridge, like the Hue dimmer switch?!

Hue Dimmer Switch

Here's the configuration for a Hue dimmer switch:

Endpoint Profile Cluster Name
01 ZLL Non-Color-Scene Controller
0000 Basic
0000 Basic
0003 Identify
0004 Groups
0006 On/Off
0008 Level Control
0005 Scenes
02 ZHA 000C
0000 Basic
0001 Power Configuration
0003 Identify
000F Binary Input (Basic)
FC00 ? Device Setup
0019 OTAU

Notes:

  • So the Hue dimmer switch does talk ZHA?!
  • deCONZ has troubles connecting to the dimmer switches. Of my six dimmer switches, only two are reporting in the web interface, and two show red.
  • The Scenes cluster is missing from one of my dimmers, which reports as a Non-Color Controler device. Not sure if this is due to a deCONZ communication error or different firmware?
  • I suspect the Binary Input (Basic) is used for buttonevent.
  • The Hue bridge has a corresponding client for the FC00 cluster.

Hue tap

The Hue tap doesn't show in the deCONZ gui.

Osram

Lightify Light

Here's the configuration for an Osram E14 bulb:

Endpoint Profile Cluster Name
03 ZLL Color Temperature Light
1000 ZLL Commissioning
0000 Basic
0003 Identify
0004 Groups
0005 Scenes
0006 On/Off
0008 Level Control
0300 Color Control
FC0F ? Device Setup
0019 OTAU

Notes:

  • No support for ZGP proxy.
  • I suspect OSRAM use the FC0F cluster for setting the power-on default.

Lightify Plug

Here's the configuration for an Osram plug:

Endpoint Profile Cluster Name
03 ZLL On/Off Plug-In Unit
1000 ZLL Commissioning
0000 Basic
0003 Identify
0004 Groups
0005 Scenes
0006 On/Off
0B04 ? Electrical Measurement
0019 OTAU

Notes:

  • I don't remember seeing some Electrical Measurement features in the OSRAM Lightly app.

innr

innr Bulbs

Here's the configuration for an innr RB 162 dimmable light:

Endpoint Profile Cluster Name
01 ZLL Dimmable Light
0000 Basic
0004 Groups
0003 Identify
0006 On/Off
0008 Level Control
0005 Scenes
02 ZLL 1000 unknown
1000 ZLL Commissioning

Notes:

  • Indeed, no over-the-air update for the firmware as innr support had indicated.
  • ZLL Commissioning is in a separate endpoint, but otherwise no surprises.
  • These lights show red after a while in the deCONZ gui. When trying to send a command (from cluster info), deCONZ reports sending failed.

innr Control Board

Here's the configuration for an innr PL 110 or UC 110, which use the same control box:

Endpoint Profile Cluster Name
01 ZLL Dimmable Light
0000 Basic
0004 Groups
0003 Identify
0006 On/Off
0008 Level Control
0005 Scenes
FFFF ?
0019 OTAU
0000 Basic
0004 Groups
0003 Identify
0006 On/Off
0008 Level Control
0005 Scenes
0019 OTAU
  • Huh, support for over-the-air update for the firmware?
  • Huh, no ZLL Commissioning? Maybe that's why these aren't listed under certified devices on the ZigBee alliance website?
  • I've no clue about the FFFF cluster.
  • The box seems to be configurable as a ZigBee control device as well. It does contain an unused header. Maybe innr uses the same board for their gateway?