C47 not connected to ground. Incorrect net. #3

Open
Bedz01 opened this issue Feb 5, 2021 · 0 comments
Open

C47 not connected to ground. Incorrect net. #3

Bedz01 opened this issue Feb 5, 2021 · 0 comments

Comments

@Bedz01
Copy link

Bedz01 commented Feb 5, 2021

I was testing a PCB that I just put together and noticed the capacitor C47 is not connected to ground.
I looked the the schematic and it turns out that the "GND" symbol is not assigned to the GND net, but rather to N0165.