Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmappings_1.h
358 lines (353 loc) · 10.8 KB
/
mappings_1.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
#include "keyValuePairs.h"
// Input from here:
//. https://github.com/TomasWallflower/Tech-CS-505/blob/master/CODES.txt
//. https://dzien.net/tech/index.php?baza=slownik
keyValuePairs<int, String> nameMapping1 {
// [0000] => None
// [0001] => Test
// [0002] => Run
// [0003] => Break
// [0004] => Run support
// [0005] => Break support
// [0006] => Manual run
// [0007] => Feeder delay
// [0008] => Blower delay
// [0009] => Temperature does not increase
// [000A] => Central heating sensor damaged
// [000B] => Central heating temperature too high
// [000C] => Hot water temperature too high
// [000D] => Damaged hot water sensor
// [000E] => Damaged feeder sensor
// [000F] => Too high feeder temperature
// [0010] => Grate
// [0011] => Failed ignition
// [0012] => Damaged exhaust gas outlet sensor
// [0013] => Damaged return sensor
// [0014] => Engine thermal
// [0015] => No communication
// [0016] => No fuel
// [0017] => Reed switch
// [0018] => Thermal protection
// [0019] => Transition phase failed
// [001A] => Extinguished
// [001B] => Floor sensor damaged
// [001C] => Fan short circuit
// [001D] => Valve sensor damaged
// [001E] => Manual operation [
// [001F] => Ignition
// [0020] => Charging
// [0021] => Disabled
// [0022] => Extinguishing
// [0023] => Ignition
// [0024] => Ignition
// [0025] => Cleaning the grate [
// [0026] => Switching off the addition
// [0027] => Initial shutdown of the grate
// [0028] => Second phase of switching off
// [0029] => Waiting to disable refilling
// [002A] => Standby
// [002B] => Transition phase
// [002C] => Transition phase
// [002D] => Ignition delay
// [002E] => Modulation operation
// [002F] => Modulation break
// [0030] => Test feeder - waiting
// [0031] => Feeder test
// [0032] => Blowing test
// [0033] => Central heating pump test
// [0034] => Hot water pump test
// [0035] => Recording test - waiting
// [0036] => Test recording
// [0037] => Setting the service code
// [0038] => Adding - waiting
// [0039] => Switching off the addition
// [003A] => Extinguishing
// [003B] => Exhaust
// [003C] => Exhaust
// [003D] => Fire test
// [003E] => 62
// [003F] => Softstart
// [0040] => Soft start
// [0041] => Work - waiting
// [0042] => Fan calibration
// [0043] => Exhaust gas sensor test
// [0044] => 68
// [0045] => T2 maintenance interval
// [0046] => T2 maintenance operation
// [0047] => Feeder delay
// [0048] => Delay airflow
// [0049] => Operation without PID
// [004A] => Maintenance break without PID
// [004B] => Maintenance operation without PID
// [004C] => Snail pre-alarm
// [004D] => Incorrect fan selection
// [004E] => Ignition
// [004F] => Ignition
// [0050] => Maintain
// [0051] => Message
// [0052] => Supervision
// [0053] => Manual Burn
// [0054] => Manual Burn
// [0055] => Manual Burn
// [0056] => Fire Test
// [0057] => Fire test
// [0058] => Fire test
// [0059] => Feeder advance
// [005A] => Feeder return
// [005B] => Blowing operation in supervision
// [005C] => Blowing pause in supervision
// [005D] = > Soft start
// [005E] => Transition phase
// [005F] => Support disabled
// [0060] => Pause
// [0061] => Fuel consumption measurement
// [00C8] => Fan control sensor defective
// [00C9] => Hall effect sensor
// [00CA] => Additional pump sensor damaged
// [00CB] => Fan control temperature too high
// [00CC] => 204
// [00CD] => No communication with the valve
// [00CE] => Weather sensor damaged
// [00CF] => Floor temperature too high
// [00D0 ] => Second buffer sensor damaged
// [00D1] => Maid sensor damaged
// [00D2] => Buffer sensor damaged
// [00D3] => Feeder hall effect sensor
// [00D4] => Solar sensor 1 damaged
// [00D5] => Solar sensor 2 damaged
// [00D6 ] => Solar sensor 3 damaged
// [00D7] => Solar sensor 4 damaged
{500, "Driver status"},
{501, "Temperature measured CO"},
{502, "Demanded central heating temperature (from the regulator)"},
{503, "503"},
// [0000] => inactive
// [0001] => active
{505, "Regulator status"},
{509, "Version"},
// [0000] => no
// [0001] => yes
{510, "hand work"},
// [0000] => not working
// [0001] => working
{511, "Feeder operation"},
// [0000] => stop
// [0001] => run
{512, "Fan operation"},
// [0000] => stop
// [0001] => run
{513, "Central heating pump operation"},
// [0000] => stop
// [0001] => run
{515, "Hot water pump operation"},
// [0000] => stop
// [0001] => run
{521, "Lighting"},
// [0000] => stop
// [0001] => start
{522, "Fade out"},
{531, "Fan speed percentage"},
{536, "FRAME: end (checksum)"},
{543, "Driver type"},
// [0000] => stop
// [0001] => run
{546, "Circulation pump operation"},
// [0000] => stop
// [0001] => run
{547, "Floor pump operation"},
{548, "Valve opening percentage"},
{549, "Cancel Alarm"},
// [0000] => to-> all devices
// [FFF4] => to-> ethernet module
// [FFFA] => to-> Tech room controller
// [FFF8] => to-> GSM module
{550, "FRAME: beginning"},
{559, "Temp. exhaust gases measured"},
// [0000] => house heating
// [0001] => boiler priority
// [0002] => parallel pumps
// [0003] => summer mode
{581, "Pump mode"},
// [0000] => Off
// [0001] => On
{648, "Standby"},
{652, "Valve temperature"},
{654, "Set hot water temperature (from the regulator)"},
{664, "Regulator time"},
// [0000] => Sunday
// [0001] => Monday
// [0002] => Tuesday
// [0003] => Wednesday
// [0004] => Thursday
// [0005] => Friday
// [0006] => Saturday
{665, "Day of the week of the regulator"},
// [0001] => CO
// [0002] => floor
{668, "Valve type"},
{742, "Temperature measured hot water"},
{759, "Valve setting (from the regulator)"},
// [0001] => enabled
// [0000] => disabled
{760, "Valve function"},
{761, "Temperture outside"},
{764, "Changing the set central heating temperature"},
{769, "RC"},
{785, "Temp. peaceful measured"},
{786, "Set room temperature"},
// [5A2D] => 45-90 degrees
{790, "minMax CO"},
{791, "minMax hot water"},
{802, "There is fuel"},
{806, "Operation of the additional pump"},
// [0001] => floor
// [0004] => circulating
{808, "Type of additional pump"},
// [0001] => on
// [0000] => off
// [] => firing up
{817, "Valve pump"},
// [FFF0] => Built-in valve 2
// [FFF1] => Built-in valve 1
{826, "Valve address"},
// [] => 10-55
{827, "minMax of the valve"},
// [0000] => with reheating
{835, "A type of summer mode"},
{867, "867"},
{869, "869"},
{871, "871"},
{873, "Fuel level"},
{874, "Fuel remaining hours"},
{880, "Temperature feeder measured"},
{887, "887"},
{898, "Changing the valve setting"},
// [0000] => connection active
// [0001] => internet module is disconnected
{899, "Status of the web module"},
// [0000] => connection active
// [0001] => main controller is disconnected
{903, "Main controller status"},
{1028,"Set room temperature min-max"},
{1029,"Users set room temperature"},
{1030,"Set room temperature correction"},
{2440,"2440"},
{2540,"2540"},
// [0002] => operation
// [0082] => supervision
// [0009] => alarm: Temperature does not rise
// [000E] => alarm: CO sensor damaged
// [000A] => alarm: Feeder sensor damaged
// [0031] => firing up
// [0027] => alarm: Floor sensor damaged
// [0029] => alarm: Valve sensor damaged
// [0052] => supervision mode
// [0050] => support (operation without PID), ST-755 controller with PID Stalmark
{5500,"Driver status (1)"},
{5501,"Measured central heating temperature"},
{5502,"Set central heating temperature"},
// [0001] => enabled
// [0000] => disabled
{5503,"TECH room regulator"},
// [0000] => stop
// [0001] => run
{5511,"Feeder"},
// [0000] => stop
// [0001] => run
{5512,"Blowing fan"},
// [0000] => stop
// [0001] => run
{5513,"Central heating pump"},
// [0000] => stop
// [0001] => run
{5515,"Hot water pump"},
{5531,"Blower fan speed"},
// [0016] => ST-730zPID / ST-755 zPid / ST-450 STALMARK? without PID? / ST-500
// [0007] => AG LUX (without PID) / K1PRv4PZ / ST-755 / K1PRv2
// [0013] => ST-450zPID
// [0015] => ST-480
// [0009] => ST-37rs
// [0008] => ST-709
// [0020] => ST-402
// [002C] => ST
// [0005] => ST- 48
// [0006] => TECH / AG LUX
// [000A] => TECH i3
{5543,"Driver type"},
{5545,"Temp. underfloor heating (from the underfloor sensor)"},
// [0000] => stop
// [0001] => run
{5546,"Hot water circulation pump"},
// [0000] => stop
// [0001] => run
{5547,"Floor pump"},
// [0000] => valve (mixing)
// [0001] => central heating valve (mixing)
// [0002] => floor valve (mixing)
{5548,"Percentage opening of the built-in valve"},
{5559,"Exhaust gas temperature"},
// [0000] => house heating
// [0001] => boiler priority
// [0002] => parallel pumps
// [0003] => summer mode
{5581,"Pump operating mode"},
{5623,"Temp. turning on the floor pump"},
{5647,"Temp. max floors"},
{5648,"Standby"},
{5652,"Valve temperature (1)"},
{5654,"Set hot water temperature "},
{5668,"Valve type"},
// [0000] => stop
// [0001] => run
{5664,"Controller time set"},
// [0000] => Sunday
// [0001] => Monday
// [0002] => Tuesday
// [0003] => Wednesday
// [0004] => Thursday
// [0005] => Friday
// [0006] => Saturday
{5665,"The set day of the week for the controller"},
{5668,"5668"},
{5742,"Measured hot water temperature"},
// [0001] => On
// [0000] => Off
{5759,"Valve setting entered"},
{5760,"Valve condition"},
{5761,"Measured outdoor temperature"},
{5785,"5785"},
{5790,"minMax CO"},
{5791,"minMax hot water"},
// [0000] => stop
// [0001] => run
{5806,"Additional pump state"},
// [0005] => disabled
// [0003] => enabled
{5808,"Additional pump operation"},
// [0000] => stop
// [0001] => run
{5814,"Circulation pump"},
// [0003] => AG-LUXbezPID
// [0005] => ST-730zPID
// [0008] => ST-450zPID
// [0006] => ST-480
{5817,"5817"},
{5887,"Driver type"},
{5880,"Feeder temperature"},
{5825,"Hot water return temperature"},
{5826,"Valve address"},
{5827,"minMax of the valve"},
{5857,"5857"},
{5868,"5868"},
{5871,"Data set number for the valve (from the controller)"},
{5873,"percentage of fuel in the tank"},
{5874,"approximate fuel supply time in hours (updated every 5 minutes)"},
{5881,"Parameter for the previous value"},
// [0000] => stop
// [0001] => run
{5898,"5898"},
{6001,"Buffer pump"},
{6024,"6024"},
{6204,"6204"},
{7014,"Setting the maximum collector operating temperature"},
};