import math
class IAQTracker:
def __init__(self, burn_in_cycles=300, gas_recal_period=3600, ph_slope=0.03):
self.slope = ph_slope
self.burn_in_cycles = burn_in_cycles
self.gas_cal_data = []
self.gas_ceil = 0
self.gas_recal_period = gas_recal_period
self.gas_recal_step = 0
def waterSatDensity(self, temp):
rho_max = (6.112 * 100 * math.exp((17.62 * temp) / (243.12 + temp))) / (461.52 * (temp + 273.15))
return rho_max
def getIAQ(self, bme_data):
temp = bme_data.temperature
hum = bme_data.humidity
R_gas = bme_data.gas_resistance
rho_max = self.waterSatDensity(temp)
hum_abs = hum * 10 * rho_max
comp_gas = R_gas * math.exp(self.slope * hum_abs)
if self.burn_in_cycles > 0:
self.burn_in_cycles -= 1
if comp_gas > self.gas_ceil:
self.gas_cal_data = [comp_gas]
self.gas_ceil = comp_gas
return None
else:
if comp_gas > self.gas_ceil:
self.gas_cal_data.append(comp_gas)
if len(self.gas_cal_data) > 100:
del self.gas_cal_data[0]
self.gas_ceil = sum(self.gas_cal_data) / len(self.gas_cal_data)
AQ = min((comp_gas / self.gas_ceil) ** 2, 1) * 100
self.gas_recal_step += 1
if self.gas_recal_step >= self.gas_recal_period:
self.gas_recal_step = 0
self.gas_cal_data.append(comp_gas)
del self.gas_cal_data[0]
self.gas_ceil = sum(self.gas_cal_data) / len(self.gas_cal_data)
return AQ