Values are ASCII-HEX, Packet must end with LF or CRLF
Field name | Bytes | Value |
---|---|---|
Start of Heading | 1 | 0x01 |
Type | 1 | 0x00 = Broadcast, 0x01 = Multicast, 0x02 = Unicast |
Unit Separator | 1 | 0x1F |
Target | 1-4 | Target address (0x0001-0x07FF for Unicast, 0x0001-0xFFFF for other Types) |
Unit Separator | 1 | 0x1F |
Soruce | 1-3 | Source address (0x000-0x7FF) |
Unit Separator | 1 | 0x1F |
Port | 1 | 0x01-0x1F for Unicast, 0xFF for other types |
Unit Separator | 1 | 0x1F |
Length | 1 | Length of following payload in bytes, 0-8 |
Start of Text | 1 | 0x02 |
Payload | 1 | Data (if length>0) |
Unit Separator | 1 | 0x1F (if length>0) - Repeat Payload/Separator for len bytes |
End of transmission | 1 | 0x04 |