Status Packets

All Outback devices provide Status packets in response to a Status command:

        Port (00: No Hub)
        |  Command (04: Status)
        |  | Address (01: Status Page 01)
        |  | |     Value (Unused)
        |  | |     |     Checksum
        |  | |………| |………| |………|
  TX: 100 02 00 01 00 00 00 03                           (Command)
  RX: 102 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF   (Response)
        | |………………………………………………………………………………………………| |………|
        | |                                      Checksum
        | Status page
        Device Type

Status responses are always 13 bytes long, but unlike other commands the first byte indicates the type of device (and therefore the type of status packet) that is being transmitted.

Checksum is a simple sum of all bytes (not including the 9th bit)

The MATE asks for a status page once per second, except for the FLEXnet DC status pages 0D..0F which are only queried when a particular screen is shown.

MX/CC

81 22 33 44 55 66 77 88 99 AA BB CC DD
||  |  |  |  |  |  |  |  | |---| |---|  
||  |  |  |  |  |  |  |  |     |     +- in_voltage      (uint16 / 10.0)
||  |  |  |  |  |  |  |  |     +------- out_voltage     (uint16 / 10.0)
||  |  |  |  |  |  |  |  +------------- kwh             (int16 / 10.0, lower byte)
||  |  |  |  |  |  |  +---------------- error           (bit field)
||  |  |  |  |  |  +------------------- status          (01..04)
||  |  |  |  |  +---------------------- aux mode / state
||  |  |  |  +------------------------- AH lower byte   (int12)
||  |  |  +---------------------------- kwh             (int16 / 10.0, upper byte)
||  |  +------------------------------- out_amps_dc     (int8, 0x80=0.0)
||  +---------------------------------- in_amps_dc      (int8, 0x80=0.0)
|+------------------------------------- out_amps_dc     (tenths, 0x01=0.1A, 0x0F=1.5A)  FM80/FM60 only
+-------------------------------------- AH upper nibble (int12, 0x800=0.0)

This status packet is quite tightly packed, and the signed integers are not your typical 2's complement.

Also, the LCD cannot display all possible values and will truncate the top digit. In practice these undisplayable values should never be encountered.

If bit7 in byte[0] is 0, then AH is not displayed in CC TOTALS screen. Presumably this is because the LCD can't display negative AmpHours, but the value is signed? Either that or there is a flag jammed into the upper nibble.

Aux Mode is bits 0..5 (0x3F), Aux State is bit 6 (0x40)

Sample values:

Mode: (blank)
In 244.5 vdc (?)62 adc
Out 70.7 vdc (?)79 adc

FX

11 22 33 44 55 66 77 88 99 AA BB CC DD
 |  |  |  |  |  |  |  |  | |---|  |  |
 |  |  |  |  |  |  |  |  |     |  |  +- warnings
 |  |  |  |  |  |  |  |  |     |  +---- misc_byte       (bit0: 230V, bit7: Aux State)
 |  |  |  |  |  |  |  |  |     +------- battery_voltage (int16 / 10.0)
 |  |  |  |  |  |  |  |  +------------- ac_mode         (0: No AC, 1: AC Drop, 2: AC Use)
 |  |  |  |  |  |  |  +---------------- errors          
 |  |  |  |  |  |  +------------------- operational_mode
 |  |  |  |  |  +---------------------- sell_current    (uint8*)
 |  |  |  |  +------------------------- output_voltage  (uint8*)
 |  |  |  +---------------------------- input_voltage   (uint8*)
 |  |  +------------------------------- buy_current     (uint8*)
 +------------------------------------- chg_current     (uint8*)

NOTE: When misc.230V == 1, you must multiply voltages by 2, and divide currents by 2

FLEXnet DC

The FLEXnet DC power monitor has multiple status pages, which are queried and combined. Pages 0A..0C are queried once per second, while pages 0D..0F are queried only every ~13 seconds.

Pages 0A..0C should be combined before parsing, as some values straddle adjacent pages.

TODO: The following is unaccounted for:

  • Shunt A/B/C enabled flag
  • Battery temperature
  • Status flags
  • Charge factor corrected battery AH/KWH

PAGE 0A

ff c8 00 5b 00 00 01 00 4c ff f2 00 17 (Capture from real device)
11 22 33 44 55 66 77 88 99 AA BB CC DD
|---| |---| |---| |---|  | |---| |---|
    |     |     |     |  |     |     +- shuntb_kw  (int16 / 100.0)
    |     |     |     |  |     +------- shunta_kw  (int16 / 100.0)
    |     |     |     |  +------------- soc        (uint8) %
    |     |     |     +---------------- bat_v      (int16 / 10.0)
    |     |     +---------------------- shuntc_cur (int16 / 10.0)
    |     +---------------------------- shuntb_cur (int16 / 10.0)
    +---------------------------------- shunta_cur (int16 / 10.0)

Sample values:

DC NOW 60.0V 153%
DC BAT 60.0V 153%

Shunt A 438.6A -18.290kW
Shunt B 1312.4A -30.910kW
Shunt C 2186.2A  0.000kW

PAGE 0B

00 00 00 21 00 5b 00 38 00 23 00 17 00 (Capture from real device)
11 22 33 44 55 66 77 88 99 AA BB CC DD
|---|  |  | |---| |---| |---| |---|  +- now_out_kw   (upper byte / 100.0)
    |  |  |     |     |     |     +---- now_in_kw    (int16 / 100.0)
    |  |  |     |     |     +---------- now_bat_cur  (int16 / 10.0)
    |  |  |     |     +---------------- now_out_cur  (int16 / 10.0)
    |  |  |     +---------------------- now_in_cur   (int16 / 10.0)
    |  |  +---------------------------- flags
    |  +------------------------------- unknown
    +---------------------------------- shuntc_kw    (int16 / 100.0)

Sample values:

DC NOW
In   2186.2A -74.600kW
Out  3060.0A -89.600kW
Bat -2619.8A -0.000kW

flags:

  • bit7 : Full settings met
  • bit6 : Unknown
  • bit5 : Unknown
  • bit0 : Unknown

PAGE 0C

0e 00 09 00 51 00 6a ff e7 00 cf 01 02 (Capture from real device)
11 22 33 44 55 66 77 88 99 AA BB CC DD
 | |---| |---| |---| |---| |---| |---|
 |     |     |     |     |     |     +- today_out_kwh (int16 / 100.0)
 |     |     |     |     |     +------- today_in_kwh  (int16 / 100.0)
 |     |     |     |     +------------- today_bat_ah  (int16)
 |     |     |     +------------------- today_out_ah  (int16)
 |     |     +------------------------- today_in_ah   (int16)
 |     +------------------------------- now_bat_kw    (int16 / 100.0)
 +------------------------------------- now_out_kw    (lower byte / 100.0)

Sample values:

DC NOW BAT KW : 87.550kW
DC NOW OUT KW : .170kW  DC TODAY IN AH : 7493AH -18.29kWH
DC TODAY OUT AH : 6231AH -30.91kWH
DC TODAY BAT AH : -567AH 0.00kWH  

DC TODAY OUT KWH : FF FF : 26.39kWH

PAGE 0D

ff cd 00 13 fe fa 02 76 01 70 ff 91 00 (Capture from real device)
11 22 33 44 55 66 77 88 00 00 00 00 00
|---| |---|     |
    |     |     +---------------------- unknown (0x01)
    |     +---------------------------- days_since_full (int16 / 10.0)
    +---------------------------------- today_bat_kwh   (int16 / 100.0)

Sample values:

DC TODAY BAT KWH : 43.86kWH

Days since full charge: 12.4

PAGE 0E

ff 00 90 fd 90 01 6a 00 00 ff 05 00 8c (Capture from real device)
11 22 33 44 55 66 77 88 99 AA BB CC DD
         |---| |---| |---| |---| |---|
             |     |     |     |     +- shuntb_ah  (int16)
             |     |     |     +------- shunta_ah  (int16)
             |     |     +------------- shuntc_kwh (int16 / 100.0)
             |     +------------------- shuntb_kwh (int16 / 100.0)
             +------------------------- shunta_kwh (int16 / 100.0)

Sample values:

Shunt A -1829AH 74.93kWH
Shunt B -3091AH 62.31kWH
Shunt C     0AH -5.67kWH

PAGE 0F

00 00 47 ff 88 fe e4 0f 00 00 00 00 00 (Capture from real device)
55 66 62 11 22 33 44 0f 00 00 00 00 00
|---|  | |---| |---|  |
    |  |     |     |  +---------------- unknown (0x0F)
    |  |     |     +------------------- bat_net_kwh   (int16 / 100.0)
    |  |     +------------------------- bat_net_ah    (int16)
    |  +------------------------------- min_soc_today (uint8)
    +---------------------------------- shuntc_ah     (int16)

Sample values:

0x1122 : 4386AH
0x3344 : (6)31.24kWH  (Note: 5th digit truncated)
0xFFFF : -1AH
0x5566 : (2)1862AH