No t2m output #543

Open
meteorids opened this issue Nov 8, 2024 · 3 comments
Open

No t2m output #543

meteorids opened this issue Nov 8, 2024 · 3 comments

Comments

@meteorids
Copy link

I am running CCPP v7, arm_sgp_summer_1997_A and B, bomex, and twice cases with GFS17_p8 and GFS16 on Hera.
For the ARM and bomex cases I get no t2m output, only for the twpice case.
Please advise.

@hertneky
Copy link
Collaborator

Thanks for bringing this to our attention. I would think t2m "should" in theory be able to be output by all these cases.

The common difference I see in the forcing file for the 3 cases that do not output t2m vs the twpice case which does output t2m, is the surface_forcing_temp. For the 3 cases that do not output t2m, the kinematic sfc flux (wpthetap) is prescibed, while twpice uses prescribed surface temperature (ts_forc).

t2m is not computed within the SCM, but rather comes from the physics from what I see. I can look more at it, but perhaps @grantfirl or @dustinswales can comment more on this.

@meteorids
Copy link
Author

meteorids commented Nov 18, 2024

Thank you for your response!
After further experimentation, I am still encountering the same issue.

@meteorids
Copy link
Author

meteorids commented Nov 20, 2024

I ran the SGP-A case with the GFS16 and GFS_v17_p8_ugwpv1 suits and the the issue persists.

@meteorids meteorids reopened this Nov 20, 2024