Hi, As far as I know, the standard resp fit schedule need two steps fit. Here only one step was performed, is that enough?
The text was updated successfully, but these errors were encountered:
See #40
Sorry, something went wrong.
Sorry for my rate reply and thanks for your question. I'll check your PR ASAP.
Though two stage fit was enforced now, there were some bugs in the code, see cdsgroup/resp#16 . And another important issue was, I don't know how to VERIFY the calculated value. I calculated the charge for ethanol, and the referenced charge was, https://pubs.acs.org/doi/suppl/10.1021/ja00074a030/suppl_file/ja00074a030_si_001.pdf There deviation ranged from 0.1 to 0.5, is that huge? @iwatobipen