\mainpage Main Page
Charger Click is a compact add-on board providing a standalone battery charger and monitor. This board features Microchip's MCP73831, a miniature single-cell, fully integrated Li-Ion, Li-Polymer charge management controller. The charge voltage of the MCP73831 is set to 4.20V, and a charge current to 250mA with an external resistor. In addition, this Click board™ features the DS2438, a smart battery monitor that monitors the total amount of current going into and out of the battery.
- Author : Stefan Filipovic
- Date : Feb 2024.
- Type : One Wire type
We provide a library for the Charger Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
This library contains API for Charger Click driver.
charger_cfg_setup
Config Object Initialization function.
void charger_cfg_setup ( charger_cfg_t *cfg );
charger_init
Initialization function.
err_t charger_init ( charger_t *ctx, charger_cfg_t *cfg );
charger_default_cfg
Click Default Configuration function.
err_t charger_default_cfg ( charger_t *ctx );
charger_read_temperature
This function reads the chip internal temperature measurement in degrees Celsius.
err_t charger_read_temperature ( charger_t *ctx, float *temperature );
charger_read_batt_vdd
This function reads the battery input voltage.
err_t charger_read_batt_vdd ( charger_t *ctx, float *voltage );
charger_read_current
This function reads the battery charging current.
err_t charger_read_current ( charger_t *ctx, float *current );
This example demonstrates the use of Charger Click board by monitoring the battery charging status.
The demo application is composed of two sections :
Initializes the driver, performs the Click default configuration, calibrates the zero current charging offset, and resets the elapsed time counter.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
charger_cfg_t charger_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
charger_cfg_setup( &charger_cfg );
CHARGER_MAP_MIKROBUS( charger_cfg, MIKROBUS_1 );
if ( ONE_WIRE_ERROR == charger_init( &charger, &charger_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( CHARGER_ERROR == charger_default_cfg ( &charger ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_printf( &logger, "\r\n Zero current calibration process\r\n" );
log_printf( &logger, " Keep the battery disconnected in the next 5 seconds\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
if ( CHARGER_ERROR == charger_calibrate_current ( &charger ) )
{
log_error( &logger, " Calibration." );
for ( ; ; );
}
log_printf( &logger, " Calibration done!\r\n\n" );
if ( CHARGER_OK == charger_write_elapsed_time ( &charger, 0 ) )
{
log_printf( &logger, " Elapsed time reset done!\r\n\n" );
}
log_info( &logger, " Application Task " );
}
Reads the chip internal temperature, battery and system VDD, battery charging current, and the elapsed time counter, approximately once per second. All data are displayed on the USB UART where you can track their changes.
void application_task ( void )
{
float temperature = 0;
float batt_vdd = 0;
float system_vdd = 0;
float current = 0;
uint32_t elapsed_time = 0;
if ( CHARGER_OK == charger_read_temperature ( &charger, &temperature ) )
{
log_printf( &logger, " Temperature: %.2f degC\r\n", temperature );
}
if ( CHARGER_OK == charger_read_batt_vdd ( &charger, &batt_vdd ) )
{
log_printf( &logger, " Battery VDD: %.3f V\r\n", batt_vdd );
}
if ( CHARGER_OK == charger_read_system_vdd ( &charger, &system_vdd ) )
{
log_printf( &logger, " System VDD: %.3f V\r\n", system_vdd );
}
if ( CHARGER_OK == charger_read_current ( &charger, ¤t ) )
{
log_printf( &logger, " Charging current: %.3f A\r\n", current );
}
if ( CHARGER_OK == charger_read_elapsed_time ( &charger, &elapsed_time ) )
{
log_printf( &logger, " Elapsed time: %lu s\r\n\n", elapsed_time );
}
Delay_ms ( 1000 );
}
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.Charger
Additional notes and informations
Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.