trim the performance measurement data to remove artifacts of "startup" and "cooldown" while reporting and evaluating #243
Comments
Just one more note, that for IperfFlowMeasurement it is not possible to do that on the reported CPU usage samples, because these are not sampled per second. Only throughput samples can be trimmed that way. |
Do we want to cut just some constant number of samples? There is also way to detect the warmup and cut just these samples. |
detection could be difficult so i think a constant cut is probably going to be fine, however if you have a good proposal for how to detect this i'd be interested in that version as well |
I'd like to have a deterministic way first, so cutting specific number of samples is ok atm. Some automated detection could be prone to unexpected behaviour of a test, so I'm a bit sceptic about it. Still, if you have a proposal, create a separate issue and you can work on that once the simple cut mechanism is implemented and merged. |
From our experience, cutting 2-3 samples from start/end of a test is a good starting point. |
Implemented in #248 |
When an ENRT recipe measures performance, for example
Recipes.ENRT.SimpleNetworkRecipe
, there are two artifacts that can impact the reported and eventually evaluation of both the CPUStatMeasurement and IperfFlowMeasurement results.For example, the following graph on the left side shows CPUStatMeasurement samples (1 sample/second) from 5 iterations. Each iteration differs in the beginning and end of the measurement - this is the source of variance when the recipe is ran and makes comparison of these runs complicated.
The solution could be to add specified time to both beginning and end of the measurement and then trim the measured samples from the beginning and end when reporting and evaluating.
For example the added time would be specified by
perf_duration_warmup
parameter. The total iperf duration then would beperf_duration + perf_duration_warmup*2
. Once the measurement completes, the samples would be trimmed to matchperf_duration_warmup, perf_duration
timestamps.The text was updated successfully, but these errors were encountered: