Winter2023: Incorrect beamspot parameter in wzp6_*_ecm240 cards #89

Open
portalesHEP opened this issue Jan 19, 2023 · 0 comments
Open

Comments

@portalesHEP
Copy link

sigma_t parameter is set to PARP(154)=1.937, while this value correspond to ecm365. Correct ecm240 value should be PARP(154)=4.243

This should not have any impact as this timing information is not propagated to the edm4hep files, but it should however be fixed if new production rounds with Whizard+Pythia6 are considered.