sigma_t parameter is set to PARP(154)=1.937, while this value correspond to ecm365. Correct ecm240 value should be PARP(154)=4.243
This should not have any impact as this timing information is not propagated to the edm4hep files, but it should however be fixed if new production rounds with Whizard+Pythia6 are considered.
The text was updated successfully, but these errors were encountered:
sigma_t parameter is set to
PARP(154)=1.937
, while this value correspond to ecm365. Correct ecm240 value should bePARP(154)=4.243
This should not have any impact as this timing information is not propagated to the edm4hep files, but it should however be fixed if new production rounds with Whizard+Pythia6 are considered.