Repeated failure of Boron wind direction pin #3

Open
thespitz opened this issue May 26, 2022 · 0 comments
Open

Repeated failure of Boron wind direction pin #3

thespitz opened this issue May 26, 2022 · 0 comments

Comments

@thespitz
Copy link
Collaborator

The analog pin for wind direction has failed and only reports 0-10 degrees. This has happened repeatedly to our station (once or twice per year) and necessitates buying a new boron or jumping to a different pin.

A pilot with EE background suggests "sounds like over-voltage on the pin, either from the sensor or from static electricity buildup. Try adding a capacitor from the analog line to ground and a TVS diode rated at the max voltage for that input."

There was no lightning at the time it failed but we do have very low humidity here and static electricity / grounding issues would be more likely than at your coastal sites