An Arduino compatible, non-blocking, I2C/SPI library for the Bosch BMP388 barometer.

NOTE: This Library is a copy from https://github.com/MartinL1/BMP388_DEV, which became unavailable in mid-2023.

alt text

© Copyright, image courtesy of Adafruit Industries lisensed under the terms of the Create Commons Attribution-ShareAlike 3.0 Unported.

This BMP388_DEV library offers the following features:

  • Returns temperature in degrees celcius (°C), pressure in hectoPascals/millibar (hPa) and altitude in metres (m)
  • NORMAL or FORCED modes of operation
  • I2C or hardware SPI communications with configurable clock rates
  • Non-blocking operation
  • In NORMAL mode barometer returns results at the specified standby time interval
  • Highly configurable, allows for changes to pressure and temperature oversampling, IIR filter and standby time
  • Polling or interrupt driven measurements (using the BMP388's external INT pin)
  • Storage and burst reading of up to 72 temperature and pressure measurements using the BMP388's internal 512 byte FIFO memory

Contents

Version

  • Version 1.0.11 -- Fixed uninitialised "Wire" pointer for ESP8266/ESP32 with user defined I2C pins
  • Version 1.0.10 -- Removed default parameter causing ESP32 compilation error with user defined I2C pins
  • Version 1.0.9 -- Fix compilation issue for STM32 Blue Pill
  • Version 1.0.8 -- Allow for additional TwoWire instances
  • Version 1.0.7 -- Fix compilation issue with Arduino Due
  • Version 1.0.6 -- Include getErrorReg() and getStatusReg() functions
  • Version 1.0.5 -- Modification to allow ESP8266 SPI operation, thanks to Adam9850 for the generating the pull request
  • Version 1.0.4 -- Fix incorrect oversampling definition for x1, thanks to myval for raising the issue
  • Version 1.0.3 -- Initialise "device" constructor member variables in the same order they are declared
  • Version 1.0.2 -- Modification to allow user-defined pins for I2C operation on the ESP32
  • Version 1.0.1 -- Fix uninitialised structures, thanks to David Jade for investigating and flagging up this issue
  • Version 1.0.0 -- Intial version

Arduino Compatibility

  • All Arduino boards, but for 5V Arduino boards (such as the Uno, Nano, Mega, Leonardo, etc...), please check if the BMP388 breakout board requires a 5V to +3.3V voltage level shifter

Installation

The BMP388_DEV library can be installed using the Arduino IDE's Library Manager. To access the Library Manager, in the Arduino IDE's menu select Sketch->Include Library->Manage Libraries.... In the Library Manager's search bar type BMP388 then select the "Install" button in the BMP388_DEV entry.

Alternatively simply download BMP388_DEV from this Github repository, un-zip or extract the files and place the BMP388_DEV directory in your .../Arduino/libraries/... folder. The .../Arduino/... folder is the one where your Arduino IDE sketches are usually located.

Usage

BMP388_DEV Library

Simply include the BMP388_DEV.h file at the beginning of your sketch:

#include <BMP388_DEV.h>

For I2C communication the BMP388_DEV object is created (instantiated) without any parameters:

BMP388_DEV bmp388;	// Set up I2C communications

Alternatively an auxiliary or secondary I2C (Wire) port can be specified:

BMP388_DEV bmp388(Wire1);  // Set up I2C communications on a secondary port

By default the library uses the BMP388's I2C address 0x77. (To use the alternate I2C address: 0x76, see the begin() function below.

The ESP8266 and ESP32 also offer the option of selecting the I2C SDA and SDA pins as parameters:

BMP388_DEV bmp388(A6, A7);	// Set up I2C communications on ESP32 pins A6 (SDA) and A7 (SCL): bmp388(SDA, SCL);

If no parameters are selected, the ESP32 uses its default SDA and SCL pins.

For SPI communication the chip select (CS) Arduino digital output pin is specified as an argument, for example digital pin 10:

BMP388_dev bmp388(10);	// Set up SPI communications on digital pin D10

The library also supports the ESP32 HSPI operation on pins: SCK 14, MOSI 13, MISO 27 and user defined SS (CS):

SPIClass SPI1(HSPI);							    // Create the SPI1 HSPI object
BMP388_DEV bmp388(21, HSPI, SPI1);		// Set up HSPI port communications on the ESP32

By default the I2C runs in fast mode at 400kHz and SPI at 1MHz. However it is possible to change either the I2C or SPI clock speed using the set clock function:

bmp388.setClock(4000000);			// Set the SPI clock to 4MHz

Device Initialisation

To initialise the BMP388 it is necessary to call the begin() function with or without arguments. The parameters specify the starting mode, pressure/temperature oversampling, IIR filter and standby time options respectively:

bmp388.begin(SLEEP_MODE, OVERSAMPLING_X16, OVERSAMPLING_X2, IIR_FILTER_4, TIME_STANDBY_5MS);

Alternatively simply call the begin function without any arguments, this sets up the default configuration: SLEEP_MODE, pressure oversampling X16, temperature oversampling X2, IIR filter OFF and a standby time of 5ms:

bmp388.begin();	// Initialise the BMP388 with default configuration

Another alternative is to pass the BMP388's mode as an argument:

bmp388.begin(NORMAL_MODE);	// Initialise the BMP388 in NORMAL_MODE with default configuration

Or, specifying mode and alternate I2C address:

bmp388.begin(FORCED_MODE, BMP388_I2C_ALT_ADDR);	// Initialise the BMP388 in FORCED_MODE with the alternate I2C address (0x76)

Or even just the alternate I2C address, (BMP388 initialised in SLEEP_MODE by default):

bmp388.begin(BMP388_I2C_ALT_ADDR);	// Initialise the BMP388 with the alternate I2C address (0x76)

Note that the begin() functions return the value 1 upon successful initialisation, otherwise it returns 0 for failure.


Device Configuration

After initialisation it is possible to change the BMP388 configuration with the following functions:

bmp388.setPresOversampling(OVERSAMPLING_X4);	// Options are OVERSAMPLING_SKIP, _X1, _X2, _X4, _X8, _X16, _32
bmp388.setTempOversampling(OVERSAMPLING_X4);	// Options are OVERSAMPLING_SKIP, _X1, _X2, _X4, _X8, _X16, _X32
bmp388.setIIRFilter(IIR_FILTER_16);	// Options are IIR_FILTER_OFF, _2, _4, _8, _16, _32
bmp388.setTimeStandby(TIME_STANDBY_2000MS);	// Options are TIME_STANDBY_5MS, _10MS, _20MS, _250MS, _40MS, _80MS, 160MS, 320MS, 640MS, 1280MS, 2560MS, 5120MS, 10240MS, 20480MS, 40960MS, 81920MS, 163840MS, 327680MS, 655360MS

Modes Of Operation

The BMP388 has 3 modes of operation: SLEEP_MODE, NORMAL_MODE and FORCED_MODE:

  • SLEEP_MODE: puts the device into an inactive standby state

  • NORMAL_MODE: performs continuous conversions, separated by the standby time

  • FORCED_MODE: performs a single conversion, returning to SLEEP_MODE upon completion

To kick-off conversions in NORMAL_MODE:

bmp388.startNormalConversion();	// Start continuous conversions, separated by the standby time

To perform a single oneshot conversion in FORCED_MODE:

bmp388.startForcedConversion();	// Start a single oneshot conversion

To stop the conversion at anytime and return to SLEEP_MODE:

bmp388.stopConversion();	// Stop conversion and return to SLEEP_MODE

Results Acquisition

The BMP388 barometer library acquires temperature in degrees celcius (°C), pressure in hectoPascals/millibar (hPa) and altitude in metres (m). The acquisition functions scan the BMP388's status register and return 1 if the barometer results are ready and have been successfully read, 0 if they are not; this allows for non-blocking code implementation. The temperature, pressure and altitude results themselves are float variables by passed reference to the function and are updated upon a successful read.

Here are the results acquisition functions:

bmp388.getMeasurements(temperature, pressure, altitude);	// Acquire temperature, pressue and altitude measurements
bmp388.getTempPres(temperature, pressure);	// Acquire both the temperature and pressure
bmp388.getTemperature(temperature);	// Acquire the temperature only
bmp388.getPressure(pressure);	// Acquire the pressure only, (also calculates temperature, but doesn't return it)
bmp388.getAltitude(altitude);	// Acquire the altitude only

Code Implementation

Here is an example sketch of how to use the BMP388 library for non-blocking I2C operation, default configuration with continuous conversion in NORMAL_MODE, but with a standby sampling time of 1 second:

#include <BMP388_DEV.h>                           // Include the BMP388_DEV.h library

float temperature, pressure, altitude;            // Create the temperature, pressure and altitude variables
BMP388_DEV bmp388;                                // Instantiate (create) a BMP388_DEV object and set-up for I2C operation (address 0x77)

void setup() 
{
  Serial.begin(115200);                           // Initialise the serial port
  bmp388.begin();                                 // Default initialisation, place the BMP388 into SLEEP_MODE 
  bmp388.setTimeStandby(TIME_STANDBY_1280MS);     // Set the standby time to 1280ms
  bmp388.startNormalConversion();                 // Start NORMAL conversion mode
}

void loop() 
{
  if (bmp388.getMeasurements(temperature, pressure, altitude))    // Check if the measurement is complete
  {
    Serial.print(temperature);                    // Display the results    
    Serial.print(F("*C   "));
    Serial.print(pressure);    
    Serial.print(F("hPa   "));
    Serial.print(altitude);
    Serial.println(F("m"));
  }
}

A second sketch example for I2C operation, default configuration in FORCED conversion mode:

#include <BMP388_DEV.h>                           // Include the BMP388_DEV.h library

float temperature, pressure, altitude;            // Create the temperature, pressure and altitude variables
BMP388_DEV bmp388;                                // Instantiate (create) a BMP388_DEV object and set-up for I2C operation (address 0x77)

void setup() 
{
  Serial.begin(115200);                           // Initialise the serial port
  bmp388.begin();                                 // Default initialisation, place the BMP388 into SLEEP_MODE 
}

void loop() 
{
  bmp388.startForcedConversion();                 // Start a forced conversion (if in SLEEP_MODE)
  if (bmp388.getMeasurements(temperature, pressure, altitude))    // Check if the measurement is complete
  {
    Serial.print(temperature);                    // Display the results    
    Serial.print(F("*C   "));
    Serial.print(pressure);    
    Serial.print(F("hPa   "));
    Serial.print(altitude);
    Serial.println(F("m"));
  }
}

The sketches for SPI operation are identical except that the line:

BMP388_DEV bmp388;	// Instantiate (create) a BMP388_DEV object and set-up for I2C operation (address 0x77)

...should be replaced with the line:

BMP388_DEV bmp388(10);	// Instantiate (create) a BMP388_DEV object and set-up for SPI operation with chip select on D10

For more details see code examples provided in the .../examples/... directory.


Additional Features

Interrupts

The BMP388 barometer has an interrupt (INT) output pin that enables measurements to be interrupt driven instead of using polling. Interrupts function in both in NORMAL and FORCED modes of operation.

Interrupts are configured by calling the enable interrupt function with or without arguments. The parameters specify whether the INT pin output drive is: PUSH_PULL or OPEN_COLLECTOR, the signal is: ACTIVE_LOW or ACTIVE_HIGH and interrupt itself is: UNLATCHED or LATCHED. In UNLATCHED mode the interrupt signal automatically clears after 2.5ms, while in LATCHED mode the interrupt signal remains active until the data is read.

The default settings are PUSH_PULL, ACTIVE_HIGH and UNLATCHED:

bmp388.enableInterrupt(PUSH_PULL, ACTIVE_HIGH, UNLATCHED);		// Enable interrupts with default settings

Alternatively the enable interrupt function with default settings can be called without any arguments:

bmp388.enableInterrupt();		// Enable interrupts with default settings

The interrupts can also be disabled by calling the disable interrupt function:

bmp388.disableInterrupt();		// Enable interrupts with default settings

The interrupt settings can also be changed independently:

bmp388.setIntOutputDrive(OPEN_COLLECTOR);		// Set the interrupt pin's output drive to open collector
bmp388.setIntActiveLevel(ACTIVE_LOW);		// Set the interrupt signal's active level to LOW
bmp388.setIntLatchConfig(LATCHED);		// Set the interrupt signal to latch until cleared

Attaching the Arduino microcontroller to the BMP388's INT pin is performed using the standard Arduino attachInterrupt() function:

attachInterrupt(digitalPinToInterrupt(2), interruptHandler, RISING);   // Set interrupt to call interruptHandler function on D2

If the SPI interface is being used and happens to be shared with other devices, then it is also necessary to call the SPI usingInterrupt function as well, (with the exception of the ESP32 and ESP8266):

bmp388.usingInterrupt(digitalPinToInterrupt(2));     // Invoke the SPI usingInterrupt() function

The I2C interface uses the Arduino Wire library. However as the Wire library generates interrupts itself during operation, it is unfortunately not possible to call the results acqusition functions (such as getTemperature(), getPressure() and getMeasurements()) from within the Interrupt Service Routine (ISR). Instead a data ready flag is set within the ISR that allows the barometer data to be read in the main loop() function.

Here is an example sketch using I2C in NORMAL_MODE, default configuration with interrupts:

//////////////////////////////////////////////////////////////////////////////////////////
// BMP388_DEV - I2C Communications, Default Configuration, Normal Conversion, Interrupt
//////////////////////////////////////////////////////////////////////////////////////////

#include <BMP388_DEV.h>                           // Include the BMP388_DEV.h library

volatile boolean dataReady = false;               // Define the data ready flag
float temperature, pressure, altitude;            // Declare the measurement variables

BMP388_DEV bmp388;                                // Instantiate (create) a BMP388_DEV object and set-up for I2C operation (address 0x77)

void setup() 
{
  Serial.begin(115200);                           // Initialise the serial port
  bmp388.begin();                                 // Default initialisation, place the BMP388 into SLEEP_MODE 
  bmp388.enableInterrupt();                       // Enable the BMP388's interrupt (INT) pin
  attachInterrupt(digitalPinToInterrupt(2), interruptHandler, RISING);   // Set interrupt to call interruptHandler function on D2
  bmp388.setTimeStandby(TIME_STANDBY_1280MS);         // Set the standby time to 1.3 seconds * 10 = measurement every 13 seconds
  bmp388.startNormalConversion();                     // Start BMP388 continuous conversion in NORMAL_MODE 
}

void loop() 
{
  if (dataReady)                                      // Check if data is ready
  {  
    bmp388.getMeasurements(temperature, pressure, altitude);      // Read the measurements
    Serial.print(temperature);                    // Display the results    
    Serial.print(F("*C   "));
    Serial.print(pressure);    
    Serial.print(F("hPa   "));
    Serial.print(altitude);
    Serial.println(F("m")); 
    dataReady = false;                            // Clear the dataReady flag
  }   
}

void interruptHandler()                           // Interrupt handler function
{
  dataReady = true;                               // Set the dataReady flag
}

The SPI interface on the other hand, does allow for the results acquisition functions to be called from within the ISR.

Here is an example sketch using SPI in NORMAL_MODE, default configuration with interrupts:

///////////////////////////////////////////////////////////////////////////////////////////
// BMP388_DEV - SPI Communications, Default Configuration, Normal Conversion, Interrupts
///////////////////////////////////////////////////////////////////////////////////////////

#include <BMP388_DEV.h>                             // Include the BMP388_DEV.h library

volatile boolean dataReady = false;									// Define the data ready flag
volatile float temperature, pressure, altitude;			// Declare the measurement variables

BMP388_DEV bmp388(10);                              // Instantiate (create) a BMP388_DEV object and set-up for SPI operation on digital pin D10

void setup() 
{
  Serial.begin(115200);                             // Initialise the serial port
  bmp388.begin();                                   // Default initialisation, place the BMP388 into SLEEP_MODE 
  bmp388.enableInterrupt();                         // Enable the BMP388's interrupt (INT) pin
  bmp388.usingInterrupt(digitalPinToInterrupt(2));  // Invoke the SPI usingInterrupt() function
  attachInterrupt(digitalPinToInterrupt(2), interruptHandler, RISING);   // Set interrupt to call interruptHandler function on D2
  bmp388.setTimeStandby(TIME_STANDBY_1280MS);       // Set the standby time to 1.3 seconds
  bmp388.startNormalConversion();                   // Start BMP388 continuous conversion in NORMAL_MODE 
}

void loop() 
{
  if (dataReady)                                    // Check if the measurement is complete
  {   
    dataReady = false;                              // Clear the data ready flag
    Serial.print(temperature);                      // Display the results    
    Serial.print(F("*C   "));
    Serial.print(pressure);    
    Serial.print(F("hPa   "));
    Serial.print(altitude);
    Serial.println(F("m"));  
  }
}

void interruptHandler()                             // Interrupt handler function
{
  bmp388.getMeasurements(temperature, pressure, altitude);    // Read the measurement data
  dataReady = true;                                 // Set the data ready flag
}

FIFO (First In First Out) Operation

The BMP388 barometer contains a 512 byte FIFO memory, capable of storing and burst reading up to 72 temperature and pressure measurements in NORMAL_MODE.

By default the BMP388_DEV library always enables temperature, pressure, altitude and sensor time. Sensor time is the internal timing of the BMP388 barometer, the datasheet however does not specify the time's units. Additional parameters include the FIFO sub-sampling time, data select and stop on FIFO full.

Sub-sampling divides down the FIFO sampling rate down further with the settings from OFF, DIV2, DIV4,...DIV128. This allows FIFO measurements to be taken over an extended period. For instance, if the barometer sampling rate is set to TIME_STANDBY_655360MS or 655.36 seconds, and the FIFO sub-sampling rate to SUBSAMPLING_DIV128 or divided down by 128, this gives a FIFO sampling time every 23 hours, 18 minutes. Over 72 samples the FIFO would return data almost every 70 days.

Data select determines whether the data placed in the FIFO is unfiltered or filtered by the IIR filter.

Stop on FIFO full, stops the FIFO from receiving data when it is full, otherwise the FIFO will continue to allow new data to overwrite old.

The enableFIFO() function parameters include pressure enable, altitude enable, sensor time enable, subsampling rate, data select and stop FIFO on full:

bmp388.enableFIFO(PRES_ENABLED, ALT_ENABLED, TIME_ENABLED, SUBSAMPLETIME_OFF, FILTERED, STOP_FIFO_ON_FULL);	// Enable FIFO with default argurments

Alternatively, to enable the FIFO with default settings and without arguments:

bmp388.enableFIFO();		// Enable the BMP388's FIFO operation

To disable the FIFO:

bmp388.disableFIFO();		// Disable the BMP388's FIFO

It is also possible to change the FIFO settings independently:

bmp388.setFIFOPressEnable(PRESS_ENABLED);		// Enable FIFO pressure measurements, options: PRESS_DISABLED, PRESS_ENABLED
bmp388.setFIFOAltEnable(ALT_ENABLED);		// Enable FIFO altitude measurements, options: ALT_DISABLED, ALT_ENABLED
bmp388.setFIFOTimeEnable(TIME_ENABLED);		// Enable FIFO sensor time, options: IME_DISABLED, TIME_ENABLED
bmp388.SetFIFOSubSampling(SUBSAMPING_OFF);	 // Enable FIFO sub-sampling, options: SUBSAMPING_OFF, DIV2, DIV4, DIV8, DIV16, DIV32, DIV64, DIV128
bmp388.SetDataSelect(FILTERED);		// Set FIFO to store unfiltered or filtered data, options UNFILITERED, FILTERED
bmp388.StopFIFOOnFull(STOP_ON_FULL_ENABLED);	// Set FIFO to stop when full, options: STOP_ON_FULL_DISABLED, STOP_ON_FULL_ENABLED

The setFIFONoOfMeasurements() function calculates the FIFO size in bytes required to store the specified number of either temperature and pressure or temperature meaurements. The function returns 1 if successful, 0 for failure, The maximum number of measurements is 72 for temperature and pressure and 126 for temperature alone:

bmp388.setFIFONoOfMeasurements(NO_OF_MEASUREMENTS);		// Calculate the size of the FIFO required to store the measurements

To check if the FIFO measurements are ready the getFIFOData() function can be polled. The function returns 1 if the measurements are ready, 0 if they are still pending. The parameters include float pointers to temperature, pressure and altitude arrays, as well the sensorTime append to each batch of measurements that is a uint32_t (unsigned long) variable passed by reference:

bmp388.getFifoData(float *temperature, float *pressure, float *altitude, float &sensorTime);

The float arrays are decleared, whose size (number of indices) matches the number of measurements:

float temperature[NO_OF_MEASUREMENTS];              // Create the temperature, pressure and altitude array variables
float pressure[NO_OF_MEASUREMENTS];
float altitude[NO_OF_MEASUREMENTS];
uint32_t sensorTime;                                // Sensor time

A pointer to the head of each temperature, pressure and altitude array, as well as the sensor time are passed to the function, each time the FIFO is polled for data:

if (bmp388.getFifoData(float temperature, float pressure, float altitude, float sensorTime)
{
	// The FIFO measurements are ready
}

Here is an example sketch using SPI in NORMAL_MODE, default configuration with FIFO operation:

/////////////////////////////////////////////////////////////////////////////////////
// BMP388_DEV - SPI Communications, Default Configuration, Normal Conversion, FIFO 
/////////////////////////////////////////////////////////////////////////////////////

#include <BMP388_DEV.h>                             // Include the BMP388_DEV.h library

#define NO_OF_MEASUREMENTS   10                     // Number of measurements to be stored in the FIFO before reading

float temperature[NO_OF_MEASUREMENTS];              // Create the temperature, pressure and altitude array variables
float pressure[NO_OF_MEASUREMENTS];
float altitude[NO_OF_MEASUREMENTS];
uint32_t sensorTime;                                // Sensor time
BMP388_DEV bmp388(10);                              // Instantiate (create) a BMP388_DEV object and set-up for SPI operation on digital pin D10

void setup() 
{
  Serial.begin(115200);                             // Initialise the serial port
  bmp388.begin();                                   // Default initialisation, place the BMP388 into SLEEP_MODE 
  bmp388.setTimeStandby(TIME_STANDBY_1280MS);       // Set the standby time to 1.3 seconds * 10 = measurement every 13 seconds
  bmp388.enableFIFO();                              // Enable the BMP388's FIFO
  bmp388.setFIFONoOfMeasurements(NO_OF_MEASUREMENTS);   // Store 10 measurements in the FIFO before reading
  bmp388.startNormalConversion();                   // Start BMP388 continuous conversion in NORMAL_MODE 
  Serial.println(F("Please wait for 13 seconds...")); // Wait message
}

void loop() 
{
  if (bmp388.getFIFOData(temperature, pressure, altitude, sensorTime))    // If the FIFO data is ready: get the 10 measurement readings
  {
    for (uint16_t i = 0; i < NO_OF_MEASUREMENTS; i++)     // Display the results 
    {
      Serial.print(i + 1);                            
      Serial.print(F(" : "));
      Serial.print(temperature[i]);                         
      Serial.print(F("*C   "));
      Serial.print(pressure[i]);    
      Serial.print(F("hPa   "));
      Serial.print(altitude[i]);
      Serial.println(F("m"));  
    }
    Serial.print(F("Sensor Time: "));
    Serial.println(sensorTime);
    Serial.println();
    Serial.println(F("Please wait for 13 seconds..."));   // Wait message
  }
}

FIFO Operation with Interrupts

In NORMAL_MODE the BMP388 barometer also allows FIFO operation to be integrated with interrupts, using its INT pin to indicate to the microcontroller when a batch of measurements are ready. This is extremely useful for ultra low power applications, since it allows the barometer to independently collect data over a long duration, while the microcontroller remains asleep.

To enable FIFO interrupts simply call the FIFO interrupt function, the parameters are identical to the standard enable interrupt function:

bmp388.enableFIFOInterrupt(PUSH_PULL, ACTIVE_HIGH, UNLATCHED);		// Enable FIFO interrupts

Alternatively, this function can also be called with default arguments:

bmp388.enableFIFOInterrupt();		// Enable FIFO interrupts

To disable FIFO interrupts:

bmp388.enableFIFOInterrupt();		// Disable FIFO interrupts

It is also possible to change the FIFO interrupt settings independently using the standard interrupt settings, for example:

bmp388.setOutputDrive(OPEN_COLLECTOR);		// Set the interrupt pin output drive to open collector

Attaching the Arduino microcontroller to the BMP388's INT pin is performed using the standard Arduino attachInterrupt() function, as described in the Interrupts section above.

When using the SPI interface with the getFIFOData() function called from within the interrupt service routine, it is necessary to declare the measurement arrays and sensor time variable as volatile:

volatile float temperature[NO_OF_MEASUREMENTS];		// Create the temperature, pressure and altitude array variables
volatile float pressure[NO_OF_MEASUREMENTS];
volatile float altitude[NO_OF_MEASUREMENTS];
volatile uint32_t sensorTime;                  		// Sensor time

Here is an example sketch using SPI in NORMAL_MODE, default configuration with FIFO operation and interrupts:

/////////////////////////////////////////////////////////////////////////////////////////////////
// BMP388_DEV - SPI Communications, Default Configuration, Normal Conversion, Interrupts, FIFO
/////////////////////////////////////////////////////////////////////////////////////////////////

#include <BMP388_DEV.h>                               // Include the BMP388_DEV.h library

#define NO_OF_MEASUREMENTS   10                       // Number of measurements to be stored in the FIFO before reading

volatile float temperature[NO_OF_MEASUREMENTS];       // Create the temperature, pressure and altitude array variables
volatile float pressure[NO_OF_MEASUREMENTS];
volatile float altitude[NO_OF_MEASUREMENTS];
volatile uint32_t sensorTime;                         // Sensor time
volatile boolean fifoDataReady = false;                
BMP388_DEV bmp388(10);                                // Instantiate (create) a BMP388_DEV object and set-up for SPI operation on digital pin D10

void setup() 
{
  Serial.begin(115200);                               // Initialise the serial port
  bmp388.begin();                                     // Default initialisation, place the BMP388 into SLEEP_MODE 
  bmp388.enableFIFOInterrupt();                       // Enable the BMP388's FIFO interrupts on the INT pin
  bmp388.usingInterrupt(digitalPinToInterrupt(2));    // Invoke the SPI usingInterrupt() function
  attachInterrupt(digitalPinToInterrupt(2), interruptHandler, RISING);   // Set interrupt to call interruptHandler function on D2
  bmp388.setTimeStandby(TIME_STANDBY_1280MS);         // Set the standby time to 1.3 seconds * 10 = measurement every 13 seconds
  bmp388.enableFIFO();                                // Enable the BMP388's FIFO
  bmp388.setFIFONoOfMeasurements(NO_OF_MEASUREMENTS); // Store 10 measurements in the FIFO before reading
  bmp388.startNormalConversion();                     // Start BMP388 continuous conversion in NORMAL_MODE 
  Serial.println(F("Please wait for 13 seconds...")); // Wait message
}

void loop() 
{
  if (fifoDataReady)                                  // If the FIFO data is ready: get the 10 measurement readings
  {
    fifoDataReady = false;                            // Clear the FIFO data ready flag
    for (uint16_t i = 0; i < NO_OF_MEASUREMENTS; i++) // Display the results 
    {
      Serial.print(i + 1);                            
      Serial.print(F(" : "));
      Serial.print(temperature[i]);                         
      Serial.print(F("*C   "));
      Serial.print(pressure[i]);    
      Serial.print(F("hPa   "));
      Serial.print(altitude[i]);
      Serial.println(F("m"));  
    }
    Serial.print(F("Sensor Time: "));
    Serial.println(sensorTime);
    Serial.println();
    Serial.println(F("Please wait for 13 seconds...")); // Wait message  
  }
}

void interruptHandler()                               // Interrupt service routine (ISR)
{  
  bmp388.getFIFOData(temperature, pressure, altitude, sensorTime);   // Get the FIFO data
  fifoDataReady = true;                               // Set the FIFO data ready flag  
}

Example Code

Here is the list of the Arduino example sketches:

  • BMP388_I2C_Normal.ino : I2C Interface, Normal Mode, Standard I2C Address (0x77)

  • BMP388_I2C_Alt_Normal.ino : I2C Interface, Normal Mode, Alternative I2C Address (0x76)

  • BMP388_I2C_Forced.ino : I2C Interface, Forced Mode

  • BMP388_I2C_Normal_Interrupt.ino : I2C Interface, Normal Mode, Interrupts

  • BMP388_I2C_Forced_Interrupt.ino : I2C Interface, Forced Mode, Interrupts

  • BMP388_I2C_Normal_FIFO.ino : I2C Interface, Normal Mode, FIFO Operation

  • BMP388_I2C_Normal_Interrupt_FIFO.ino : I2C Interface, Normal Mode, Interrupts, FIFO Operation

  • BMP388_SPI_Normal.ino : SPI Interface, Normal Mode

  • BMP388_SPI_Forced.ino : SPI Interface, Forced Mode

  • BMP388_SPI_Normal_Interrupt.ino : SPI Interface, Normal Mode, Interrupts

  • BMP388_SPI_Forced_Interrupt.ino : SPI Interface, Forced Mode, Interrupts

  • BMP388_SPI_Normal_FIFO.ino : SPI Interface, Normal Mode, FIFO Operation

  • BMP388_SPI_Normal_Interrupt_FIFO.ino : SPI Interface, Normal Mode, Interrupts, FIFO Operation

  • BMP388_SPI_Normal_Multiple.ino : SPI Interface, Normal Mode, Multiple Devices

  • BMP388_ESP32_HSPI_Normal.ino : ESP32 HSPI Interface, Normal Mode

  • BMP388_ESP8266_I2C_Normal_DefinedPins.ino : ESP8266 I2C Interface, Normal Mode, User-Defined Pins

  • BMP388_ESP32_I2C_Normal_DefinedPins.ino : ESP32 I2C Interface, Normal Mode, User-Defined Pins